{"title":"Trace element determination by femtosecond LA-ICP-MS in 10 mg extraterrestrial geological samples prepared as lithium borate glasses†","authors":"Yan-Hong Liu, Ding-Shuai Xue, Wen-Jun Li, Zhong-Qiang Wang, Yan Liang, Shun Guo and Bo Wan","doi":"10.1039/D4JA00275J","DOIUrl":null,"url":null,"abstract":"<p >Bulk chemical composition analysis is a primary and pivotal analytical task for extraterrestrial geological samples (<em>e.g.</em>, lunar soil, asteroids, or meteoroids). However, the analysis of mg-level consumption of extraterrestrial geological samples poses a significant challenge to existing analytical techniques. In this study, a new method was developed for trace element determination in bulk extraterrestrial geological samples prepared as lithium borate glasses, following customized procedures for X-ray fluorescence (XRF) analysis with a 10 mg sample by femtosecond LA-ICP-MS. All thirty-two trace elements in the borate glass samples were evenly distributed with homogeneity indices (<em>H</em>) &lt; <em>H</em><small><sub>crit</sub></small>. For the borate glass samples, Si was more suitable as an internal standard for Co, Ni, Cu, and Zn, whereas Al was better for the others. The femtosecond laser greatly reduces the influence of matrix effects, making calibration with non-matrix-matched external standards (NIST 612 and 614) accurate. Although the mass ratio of the flux and sample was as high as 35 : 1, the analytical results of 32 trace elements in six silicate rock reference materials (covering mafic to felsic rock types) using the developed technique were consistent with the reference values within 10% for most elements, and analytical precision (RSD) was also within 10% for most elements. Finally, one lunar basalt (NWA14526) and one shergottite (NWA13190) were assayed using the proposed method, and a comparison with the results of solution nebulization (SN)-ICP-MS confirmed the reliability of the method. The proposed method, combined with XRF, achieved the rapid, simultaneous, and accurate determination of major and trace elements in the same small sample aliquot (10 mg), which is highly suitable for the analysis of extraterrestrial geological samples.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 11","pages":" 2728-2736"},"PeriodicalIF":3.1000,"publicationDate":"2024-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/ja/d4ja00275j","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Bulk chemical composition analysis is a primary and pivotal analytical task for extraterrestrial geological samples (e.g., lunar soil, asteroids, or meteoroids). However, the analysis of mg-level consumption of extraterrestrial geological samples poses a significant challenge to existing analytical techniques. In this study, a new method was developed for trace element determination in bulk extraterrestrial geological samples prepared as lithium borate glasses, following customized procedures for X-ray fluorescence (XRF) analysis with a 10 mg sample by femtosecond LA-ICP-MS. All thirty-two trace elements in the borate glass samples were evenly distributed with homogeneity indices (H) < Hcrit. For the borate glass samples, Si was more suitable as an internal standard for Co, Ni, Cu, and Zn, whereas Al was better for the others. The femtosecond laser greatly reduces the influence of matrix effects, making calibration with non-matrix-matched external standards (NIST 612 and 614) accurate. Although the mass ratio of the flux and sample was as high as 35 : 1, the analytical results of 32 trace elements in six silicate rock reference materials (covering mafic to felsic rock types) using the developed technique were consistent with the reference values within 10% for most elements, and analytical precision (RSD) was also within 10% for most elements. Finally, one lunar basalt (NWA14526) and one shergottite (NWA13190) were assayed using the proposed method, and a comparison with the results of solution nebulization (SN)-ICP-MS confirmed the reliability of the method. The proposed method, combined with XRF, achieved the rapid, simultaneous, and accurate determination of major and trace elements in the same small sample aliquot (10 mg), which is highly suitable for the analysis of extraterrestrial geological samples.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用飞秒 LA-ICP-MS 测定制备成硼酸锂玻璃的 10 毫克地外地质样品中的痕量元素†。
大块化学成分分析是地外地质样品(如月球土壤、小行星或流星体)的主要和关键分析任务。然而,地外地质样品毫克级消耗量的分析对现有分析技术提出了巨大挑战。本研究开发了一种新方法,用于测定制备成硼酸锂玻璃的大量地外地质样品中的痕量元素,该方法采用定制的 X 射线荧光 (XRF) 分析程序,通过飞秒 LA-ICP-MS 对 10 毫克样品进行分析。硼酸盐玻璃样品中的 32 种微量元素分布均匀,均匀度指数 (H) < Hcrit。在硼酸盐玻璃样品中,Si 更适合作为 Co、Ni、Cu 和 Zn 的内标,而 Al 则更适合作为其他元素的内标。飞秒激光大大降低了基体效应的影响,使非基体匹配外部标准(NIST 612 和 614)的校准变得精确。虽然通量和样品的质量比高达 35 :尽管通量和样品的质量比高达 35:1,但利用所开发的技术对六种硅酸盐岩石参考材料(涵盖岩浆岩到长英岩类型)中 32 种微量元素的分析结果与参考值一致,大多数元素的分析精度(RSD)在 10%以内,大多数元素的分析精度(RSD)也在 10%以内。最后,利用所提出的方法化验了一块月球玄武岩(NWA14526)和一块闪长岩(NWA13190),并与溶液雾化(SN)-ICP-MS 的结果进行了比较,证实了该方法的可靠性。所提出的方法与 XRF 相结合,实现了在同一小份样品(10 毫克)中快速、同步、准确地测定主要元素和痕量元素,非常适合地外地质样品的分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
期刊最新文献
Dynamic vision sensor enhanced laser-induced breakdown spectroscopy: parameter optimisation and correction method for improving spectral stability Feasibility of rare earth element determination in edible insects by USN-ICP-MS after microwave-assisted UV digestion using diluted acids Precision and accuracy of highly-enriched double-spike Fe taggant measurements using quadrupole- and multicollector-ICP-MS Quantitative LIBS analysis of microalloyed steel using LASSO–LightGBM modeling with SHAP-based interpretability Development and investigation of efficient resonance ionization mass spectrometry schemes of gadolinium
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1