Nader Hassan , Salah El-Bahy , Ahmed O. Babalghith , Refat El-Sayed , Khaled F. Debbabi , Alaa S. Amin
{"title":"Development of a high-performance optical sensor for sensitive detection of cobalt ions in pharmaceutical, food, biological, and environmental samples","authors":"Nader Hassan , Salah El-Bahy , Ahmed O. Babalghith , Refat El-Sayed , Khaled F. Debbabi , Alaa S. Amin","doi":"10.1016/j.saa.2024.125343","DOIUrl":null,"url":null,"abstract":"<div><div>A re-generable optical chemical sensing film was created using a modified chitosan film that incorporates immobilized 4-(thiazol-2-yldiazenyl) benzene-1,3-diol (TDBD) for the detection of Co<sup>2+</sup> in acidic aqueous solutions. Upon exposure to Co<sup>2+</sup>, the film’s color shifted from yellowish green to red by forming a complex between Co<sup>2+</sup> and TDBD. The sensor’s complex was measured at 574 nm, a wavelength where the sensing membrane exhibited minimal background interference. The film exhibited its highest responsiveness to cobalt ions at pH 5.0. Two sample volumes were analysed: 2.5 mL with a Co<sup>2+</sup> concentration range of 8.0–140 ng/mL, and 250 mL with a concentration range of 2.4–15.2 ng/mL. Both sample sizes produced linear calibration curves, with detection limits of 2.5 and 0.7 ng/mL, respectively. The relative standard deviation was 1.35 % for six separate films in a 100 ng/mL Co<sup>2+</sup> solution, and 0.87 % for six individual films in a 10 ng/mL solution using 2.5 and 250 ng/mL, respectively. The sensing films demonstrated good stability over 30 days and were successfully used to determine Co<sup>2+</sup> in pharmaceutical, food, environmental, and biological samples, yielding satisfactory results compared to the ICP-AES method.</div></div>","PeriodicalId":433,"journal":{"name":"Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy","volume":"327 ","pages":"Article 125343"},"PeriodicalIF":4.3000,"publicationDate":"2024-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1386142524015099","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 0
Abstract
A re-generable optical chemical sensing film was created using a modified chitosan film that incorporates immobilized 4-(thiazol-2-yldiazenyl) benzene-1,3-diol (TDBD) for the detection of Co2+ in acidic aqueous solutions. Upon exposure to Co2+, the film’s color shifted from yellowish green to red by forming a complex between Co2+ and TDBD. The sensor’s complex was measured at 574 nm, a wavelength where the sensing membrane exhibited minimal background interference. The film exhibited its highest responsiveness to cobalt ions at pH 5.0. Two sample volumes were analysed: 2.5 mL with a Co2+ concentration range of 8.0–140 ng/mL, and 250 mL with a concentration range of 2.4–15.2 ng/mL. Both sample sizes produced linear calibration curves, with detection limits of 2.5 and 0.7 ng/mL, respectively. The relative standard deviation was 1.35 % for six separate films in a 100 ng/mL Co2+ solution, and 0.87 % for six individual films in a 10 ng/mL solution using 2.5 and 250 ng/mL, respectively. The sensing films demonstrated good stability over 30 days and were successfully used to determine Co2+ in pharmaceutical, food, environmental, and biological samples, yielding satisfactory results compared to the ICP-AES method.
期刊介绍:
Spectrochimica Acta, Part A: Molecular and Biomolecular Spectroscopy (SAA) is an interdisciplinary journal which spans from basic to applied aspects of optical spectroscopy in chemistry, medicine, biology, and materials science.
The journal publishes original scientific papers that feature high-quality spectroscopic data and analysis. From the broad range of optical spectroscopies, the emphasis is on electronic, vibrational or rotational spectra of molecules, rather than on spectroscopy based on magnetic moments.
Criteria for publication in SAA are novelty, uniqueness, and outstanding quality. Routine applications of spectroscopic techniques and computational methods are not appropriate.
Topics of particular interest of Spectrochimica Acta Part A include, but are not limited to:
Spectroscopy and dynamics of bioanalytical, biomedical, environmental, and atmospheric sciences,
Novel experimental techniques or instrumentation for molecular spectroscopy,
Novel theoretical and computational methods,
Novel applications in photochemistry and photobiology,
Novel interpretational approaches as well as advances in data analysis based on electronic or vibrational spectroscopy.