Renpu Li , Zhaoyang Wang , Junsen Yuan , Jiwen Cui , Andrei Kulikov , Igor Konyakhin , Yongrui Guo , Yujia Huo , Dandan Wen , Ke Di
{"title":"Influence of background noise on autocollimator measurement precision and method for uncertainty source elimination","authors":"Renpu Li , Zhaoyang Wang , Junsen Yuan , Jiwen Cui , Andrei Kulikov , Igor Konyakhin , Yongrui Guo , Yujia Huo , Dandan Wen , Ke Di","doi":"10.1016/j.measurement.2024.116036","DOIUrl":null,"url":null,"abstract":"<div><div>Reflection phenomenon of internal optical structure surface of the autocollimator will cause background noise to interfere with its imaging and localization results, thus reducing the measurement precision. The non-working surface reflection of the beam splitter is the main factor causing this uncertainty source. Using a polarized beam splitter cube to replace the original beam splitter and combining with other polarization devices can effectively suppress the influence of this uncertainty source on the goniometric accuracy of the autocollimator. In this paper, through the comparison experiment with the benchmark instrument, it is found that after eliminating the noise, the measurement accuracy along the X and Y axes is improved from less than 5.26″ to better than 2.69″, the resolution is improved from 2″ to approximately 1″, and the uncertainty of the systematic measurement is improved from 5.67″ to approximately 3.43″.</div></div>","PeriodicalId":18349,"journal":{"name":"Measurement","volume":"242 ","pages":"Article 116036"},"PeriodicalIF":5.2000,"publicationDate":"2024-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0263224124019213","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Reflection phenomenon of internal optical structure surface of the autocollimator will cause background noise to interfere with its imaging and localization results, thus reducing the measurement precision. The non-working surface reflection of the beam splitter is the main factor causing this uncertainty source. Using a polarized beam splitter cube to replace the original beam splitter and combining with other polarization devices can effectively suppress the influence of this uncertainty source on the goniometric accuracy of the autocollimator. In this paper, through the comparison experiment with the benchmark instrument, it is found that after eliminating the noise, the measurement accuracy along the X and Y axes is improved from less than 5.26″ to better than 2.69″, the resolution is improved from 2″ to approximately 1″, and the uncertainty of the systematic measurement is improved from 5.67″ to approximately 3.43″.
期刊介绍:
Contributions are invited on novel achievements in all fields of measurement and instrumentation science and technology. Authors are encouraged to submit novel material, whose ultimate goal is an advancement in the state of the art of: measurement and metrology fundamentals, sensors, measurement instruments, measurement and estimation techniques, measurement data processing and fusion algorithms, evaluation procedures and methodologies for plants and industrial processes, performance analysis of systems, processes and algorithms, mathematical models for measurement-oriented purposes, distributed measurement systems in a connected world.