Analysis of painful situations during unsedated esophagogastroduodenoscopy.

IF 2.2 Q3 GASTROENTEROLOGY & HEPATOLOGY Endoscopy International Open Pub Date : 2024-11-07 eCollection Date: 2024-11-01 DOI:10.1055/a-2401-6804
Hiromitsu Kanzaki, Sakiko Kuraoka, Takuya Satomi, Shotaro Okanoue, Kenta Hamada, Yoshiyasu Kono, Masaya Iwamuro, Seiji Kawano, Yoshiro Kawahara, Hiroyuki Okada, Motoyuki Otsuka
{"title":"Analysis of painful situations during unsedated esophagogastroduodenoscopy.","authors":"Hiromitsu Kanzaki, Sakiko Kuraoka, Takuya Satomi, Shotaro Okanoue, Kenta Hamada, Yoshiyasu Kono, Masaya Iwamuro, Seiji Kawano, Yoshiro Kawahara, Hiroyuki Okada, Motoyuki Otsuka","doi":"10.1055/a-2401-6804","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background and study aims</b> Although esophagogastroduodenoscopy (EGD) is a widely used technique, the procedure is often associated with discomfort. This study aimed to analyze painful situations, their frequency, and factors associated with patient discomfort during EGD. <b>Patients and methods</b> This prospective observational study included patients scheduled to undergo EGD. Seven endoscopists recruited patients scheduled for EGD screening or surveillance. Each endoscopist enrolled 20 patients, performing 10 EGD procedures using ultraslim endoscopes and 10 with standard-sized endoscopes. Data regarding painful situations and frequency were collected using specialized buttons pressed by the patients during EGD. A survey about overall discomfort was conducted after the procedure. <b>Results</b> We analyzed data from 140 patients. Esophageal insertion and duodenal observation were associated with the highest incidence of pressing the pain button, accounting for 59.3% and 40.7% of the cases, respectively. The factor associated with pressing the pain button during esophageal insertion was endoscopist experience (< 10 years). In contrast, younger age and female sex were the factors associated with pressing the pain button during duodenal observation. In the post-procedure survey, 63.6% of patients reported discomfort. Factors associated with patient discomfort included pressing the pain button during esophageal insertion (odds ratio [OR]: 2.84, <i>P</i> = 0.01) and previous painful EGD experience (OR: 2.41, <i>P</i> = 0.03). <b>Concusions</b> This study provides objective data on painful situations, their frequency, and related factors during EGD. Further research and interventions focusing on pain reduction during endoscopic procedures are warranted. The results of this study will help endoscopists manage painful situations and potentially improve skills.</p>","PeriodicalId":11671,"journal":{"name":"Endoscopy International Open","volume":"12 11","pages":"E1267-E1276"},"PeriodicalIF":2.2000,"publicationDate":"2024-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11543283/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Endoscopy International Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/a-2401-6804","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and study aims Although esophagogastroduodenoscopy (EGD) is a widely used technique, the procedure is often associated with discomfort. This study aimed to analyze painful situations, their frequency, and factors associated with patient discomfort during EGD. Patients and methods This prospective observational study included patients scheduled to undergo EGD. Seven endoscopists recruited patients scheduled for EGD screening or surveillance. Each endoscopist enrolled 20 patients, performing 10 EGD procedures using ultraslim endoscopes and 10 with standard-sized endoscopes. Data regarding painful situations and frequency were collected using specialized buttons pressed by the patients during EGD. A survey about overall discomfort was conducted after the procedure. Results We analyzed data from 140 patients. Esophageal insertion and duodenal observation were associated with the highest incidence of pressing the pain button, accounting for 59.3% and 40.7% of the cases, respectively. The factor associated with pressing the pain button during esophageal insertion was endoscopist experience (< 10 years). In contrast, younger age and female sex were the factors associated with pressing the pain button during duodenal observation. In the post-procedure survey, 63.6% of patients reported discomfort. Factors associated with patient discomfort included pressing the pain button during esophageal insertion (odds ratio [OR]: 2.84, P = 0.01) and previous painful EGD experience (OR: 2.41, P = 0.03). Concusions This study provides objective data on painful situations, their frequency, and related factors during EGD. Further research and interventions focusing on pain reduction during endoscopic procedures are warranted. The results of this study will help endoscopists manage painful situations and potentially improve skills.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
分析无麻醉食管胃十二指肠镜检查时的疼痛情况。
背景和研究目的 虽然食管胃十二指肠镜检查(EGD)是一种广泛使用的技术,但该检查过程经常会引起不适。本研究旨在分析胃肠镜检查过程中的疼痛情况、疼痛频率以及与患者不适相关的因素。患者和方法 这项前瞻性观察研究纳入了计划接受胃肠镜检查的患者。七名内镜医师招募了计划接受胃肠造影检查或监测的患者。每位内镜医师招募了 20 名患者,使用超薄内镜进行了 10 次胃肠造影术,使用标准尺寸内镜进行了 10 次胃肠造影术。患者在做胃肠镜检查时按下专用按钮,收集有关疼痛情况和频率的数据。术后还进行了一项关于总体不适感的调查。结果 我们分析了 140 名患者的数据。食管插入和十二指肠观察是按下疼痛按钮发生率最高的部位,分别占 59.3% 和 40.7%。在食管插入过程中按下疼痛按钮的相关因素是内镜医师的经验(小于 10 年)。相比之下,年轻和女性是在十二指肠观察时按下疼痛按钮的相关因素。在手术后调查中,63.6%的患者表示不适。与患者不适相关的因素包括在食管插入过程中按下疼痛按钮(几率比 [OR]:2.84,P = 0.01)和之前的胃肠造影疼痛经历(OR:2.41,P = 0.03)。结论 本研究提供了有关胃肠造影术中疼痛情况、疼痛频率及相关因素的客观数据。有必要进一步开展研究并采取干预措施,重点减少内窥镜手术过程中的疼痛。这项研究的结果将有助于内镜医师处理疼痛情况,并有可能提高技能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Endoscopy International Open
Endoscopy International Open GASTROENTEROLOGY & HEPATOLOGY-
自引率
3.80%
发文量
270
期刊最新文献
New cholangiopancreatoscopy-assisted diagnosis of disconnected pancreatic cuct syndrome and bridging disconnected pancreatic duct. Colonoscopy is not mammography: Challenges of applying the Duty of Candor. Complete extraction of main pancreatic duct residual and microstones using an 8-wire basket catheter. Costs and benefits of a formal quality framework for colonoscopy: Economic evaluation. Defining standards for fluoroscopy in gastrointestinal endoscopy using Delphi methodology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1