Haochen Zhu, Xinyi Xia, Chao-Ching Chiang, Rachael S Watson Levings, Justin Correa, Fernanda Regina Godoy Rocha, Steve C Ghivizzani, Fan Ren, Dan Neal, Patricia Dos Santos Calderon, Josephine F Esquivel-Upshaw
{"title":"Osteoblast Growth in Quaternized Silicon Carbon Nitride Coatings for Dental Implants.","authors":"Haochen Zhu, Xinyi Xia, Chao-Ching Chiang, Rachael S Watson Levings, Justin Correa, Fernanda Regina Godoy Rocha, Steve C Ghivizzani, Fan Ren, Dan Neal, Patricia Dos Santos Calderon, Josephine F Esquivel-Upshaw","doi":"10.3390/ma17215392","DOIUrl":null,"url":null,"abstract":"<p><p>The demand for dental implants has increased, establishing them as the standard of care for replacing missing teeth. Several factors contribute to the success or failure of an implant post-placement. Modifications to implant surfaces can enhance the biological interactions between bone cells and the implant, promoting better outcomes. Surface coatings have been developed to electrochemically alter implant surfaces, aiming to reduce healing time, enhance bone growth, and prevent bacterial adhesion. Quaternized silicon carbon nitride (QSiCN) is a novel material with unique electrochemical and biological properties. This study aimed to assess the influence of QSiCN, silicon carbide nitride (SiCN), and silicon carbide (SiC) coatings on the viability of osteoblast cells on nanostructured titanium surfaces. The experiment utilized thirty-two titanium sheets with anodized TiO<sub>2</sub> nanotubes featuring nanotube diameters of 50 nm and 150 nm. These sheets were divided into eight groups (n = 4): QSiCN-coated 50 nm, QSiCN-coated 150 nm, SiCN-coated 50 nm, SiCN-coated 150 nm, SiC-coated 50 nm, SiC-coated 150 nm, non-coated 50 nm, and non-coated 150 nm. Preosteoblast MC3T3-E1 Subclone 4 cells (ATCC, USA) were used to evaluate osteoblast viability. After three days of cell growth, samples were assessed using scanning electron microscopy (SEM). The results indicated that QSiCN coatings significantly increased osteoblast proliferation (<i>p</i> < 0.005) compared to other groups. The enhanced cell adhesion observed with QSiCN coatings is likely due to the positive surface charge imparted by N<sup>+</sup>.</p>","PeriodicalId":18281,"journal":{"name":"Materials","volume":"17 21","pages":""},"PeriodicalIF":3.1000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11547877/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Materials","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.3390/ma17215392","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0
Abstract
The demand for dental implants has increased, establishing them as the standard of care for replacing missing teeth. Several factors contribute to the success or failure of an implant post-placement. Modifications to implant surfaces can enhance the biological interactions between bone cells and the implant, promoting better outcomes. Surface coatings have been developed to electrochemically alter implant surfaces, aiming to reduce healing time, enhance bone growth, and prevent bacterial adhesion. Quaternized silicon carbon nitride (QSiCN) is a novel material with unique electrochemical and biological properties. This study aimed to assess the influence of QSiCN, silicon carbide nitride (SiCN), and silicon carbide (SiC) coatings on the viability of osteoblast cells on nanostructured titanium surfaces. The experiment utilized thirty-two titanium sheets with anodized TiO2 nanotubes featuring nanotube diameters of 50 nm and 150 nm. These sheets were divided into eight groups (n = 4): QSiCN-coated 50 nm, QSiCN-coated 150 nm, SiCN-coated 50 nm, SiCN-coated 150 nm, SiC-coated 50 nm, SiC-coated 150 nm, non-coated 50 nm, and non-coated 150 nm. Preosteoblast MC3T3-E1 Subclone 4 cells (ATCC, USA) were used to evaluate osteoblast viability. After three days of cell growth, samples were assessed using scanning electron microscopy (SEM). The results indicated that QSiCN coatings significantly increased osteoblast proliferation (p < 0.005) compared to other groups. The enhanced cell adhesion observed with QSiCN coatings is likely due to the positive surface charge imparted by N+.
期刊介绍:
Materials (ISSN 1996-1944) is an open access journal of related scientific research and technology development. It publishes reviews, regular research papers (articles) and short communications. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. Therefore, there is no restriction on the length of the papers. The full experimental details must be provided so that the results can be reproduced. Materials provides a forum for publishing papers which advance the in-depth understanding of the relationship between the structure, the properties or the functions of all kinds of materials. Chemical syntheses, chemical structures and mechanical, chemical, electronic, magnetic and optical properties and various applications will be considered.