Effect of Repeated Firings on Color Stability of Zirconia- Reinforced Lithium Silicate and Lithium Disilicate Ceramics.

IF 1.1 Q3 DENTISTRY, ORAL SURGERY & MEDICINE European Journal of Prosthodontics and Restorative Dentistry Pub Date : 2024-11-13 DOI:10.1922/EJPRD_2466Habibkhodaei07
M Habibkhodaei, R Mosharraf, O Savabi, F Salehi Ghalesefid
{"title":"Effect of Repeated Firings on Color Stability of Zirconia- Reinforced Lithium Silicate and Lithium Disilicate Ceramics.","authors":"M Habibkhodaei, R Mosharraf, O Savabi, F Salehi Ghalesefid","doi":"10.1922/EJPRD_2466Habibkhodaei07","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this invitro study was to assess the changes in the color attributes of high-translucency (HT) lithium disilicate and zirconia-reinforced lithium silicate in BL3/0M1, A1, A2, and A3 shades during first, second, and third firing cycles.</p><p><strong>Materials and methods: </strong>Eighty specimens of two ceramic systems (IPS e.max CAD and Vita Suprinity) in BL3/0M1, A1, A2, and A3 shades, were prepared in thickness of 1 mm (n=10). Each group was subjected to 3 firing cycles and the CIE L*a*b* color parameters of specimens were measured after each firing cycle by a reflectance spectrophotometer. The color change (ΔE) between each two firing cycles was calculated by the relevant equation. Data were analyzed by one-way ANOVA and Tamhane post hoc test.</p><p><strong>Results: </strong>All ΔE values were significant (P⟨0.001) except for ΔE2-1 (color difference between second and first firing) and ΔE3-2 (color difference between third and second firing) in A2 shade of IPS e.max (P=0.436) and ΔE2-1 and ΔE3-2 in 0M1 shade of Suprinity (P=0.345).</p><p><strong>Conclusion: </strong>Repeated firing resulted in generally higher ΔE in ZLS than LDS, and 0M1 Suprinity experienced maximum ΔE after repeating firing.</p>","PeriodicalId":45686,"journal":{"name":"European Journal of Prosthodontics and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2024-11-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Prosthodontics and Restorative Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1922/EJPRD_2466Habibkhodaei07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The purpose of this invitro study was to assess the changes in the color attributes of high-translucency (HT) lithium disilicate and zirconia-reinforced lithium silicate in BL3/0M1, A1, A2, and A3 shades during first, second, and third firing cycles.

Materials and methods: Eighty specimens of two ceramic systems (IPS e.max CAD and Vita Suprinity) in BL3/0M1, A1, A2, and A3 shades, were prepared in thickness of 1 mm (n=10). Each group was subjected to 3 firing cycles and the CIE L*a*b* color parameters of specimens were measured after each firing cycle by a reflectance spectrophotometer. The color change (ΔE) between each two firing cycles was calculated by the relevant equation. Data were analyzed by one-way ANOVA and Tamhane post hoc test.

Results: All ΔE values were significant (P⟨0.001) except for ΔE2-1 (color difference between second and first firing) and ΔE3-2 (color difference between third and second firing) in A2 shade of IPS e.max (P=0.436) and ΔE2-1 and ΔE3-2 in 0M1 shade of Suprinity (P=0.345).

Conclusion: Repeated firing resulted in generally higher ΔE in ZLS than LDS, and 0M1 Suprinity experienced maximum ΔE after repeating firing.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
反复烧结对氧化锆增强型硅酸锂和二硅酸锂陶瓷颜色稳定性的影响
目的:这项体外研究的目的是评估BL3/0M1、A1、A2和A3色调的高透明度(HT)二硅酸锂和氧化锆增强硅酸锂在第一、第二和第三烧结周期中颜色属性的变化:制备了两种陶瓷系统(IPS e.max CAD 和 Vita Suprinity)的 80 个试样,色调分别为 BL3/0M1、A1、A2 和 A3,厚度均为 1 毫米(n=10)。每组试样经过 3 个烧制周期,每个烧制周期结束后用反射分光光度计测量试样的 CIE L*a*b* 颜色参数。每两个焙烧周期之间的颜色变化(ΔE)由相关公式计算得出。数据分析采用单因素方差分析和 Tamhane 后检验:除了 IPS e.max 的 A2 色调中的ΔE2-1(第二次与第一次焙烧之间的色差)和ΔE3-2(第三次与第二次焙烧之间的色差)(P=0.436)以及 Suprinity 的 0M1 色调中的ΔE2-1 和 ΔE3-2(P=0.345)之外,所有的ΔE 值都具有显著性(P⟨0.001):重复焙烧导致 ZLS 的 ΔE 普遍高于 LDS,0M1 Suprinity 在重复焙烧后出现最大 ΔE。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.30
自引率
7.70%
发文量
0
期刊介绍: The European Journal of Prosthodontics and Restorative Dentistry is published quarterly and includes clinical and research articles in subjects such as prosthodontics, operative dentistry, implantology, endodontics, periodontics and dental materials.
期刊最新文献
Effect of Repeated Firings on Color Stability of Zirconia- Reinforced Lithium Silicate and Lithium Disilicate Ceramics. Success and Survival of Composite Resin Restorations for the Management of Localized Anterior Tooth Wear: A Systematic Review and Meta-Analysis. Tensile Bond Strength, Fit Accuracy and Failure Types of Zirconia and Cast Gold Root Copings for Overdentures. Clinical Performance of 3D Printed Resin Composite Posterior Fixed Dental Prosthesis: A Permanent Solution? Letter to the Editor.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1