Effect of CAD-CAM block thickness and translucency on the polymerization of luting materials.

IF 2.6 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE BMC Oral Health Pub Date : 2024-11-15 DOI:10.1186/s12903-024-05171-z
Bengü Doğu Kaya, Selinsu Öztürk, Ayşe Aslı Şenol, Erkut Kahramanoğlu, Pınar Yılmaz Atalı, Bilge Tarçın
{"title":"Effect of CAD-CAM block thickness and translucency on the polymerization of luting materials.","authors":"Bengü Doğu Kaya, Selinsu Öztürk, Ayşe Aslı Şenol, Erkut Kahramanoğlu, Pınar Yılmaz Atalı, Bilge Tarçın","doi":"10.1186/s12903-024-05171-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>This in-vitro study aimed to evaluate the degree of conversion (DC) of dual-cured luting cement (Bifix QM, VOCO) and flowable composite (Grandio Flow, VOCO) under lithium disilicate glass-ceramic (IPS e.max CAD, Ivoclar Vivadent) and hybrid ceramic (Grandio Blocs, VOCO; Cerasmart, GC) CAD-CAM blocks with different thicknesses.</p><p><strong>Materials and methods: </strong>Contrast ratio (CR), translucency (TP<sub>ab</sub>, TP<sub>00</sub>), and opalescence (OP) parameters of 30 disc-shaped CAD-CAM blocks (n = 5) prepared with two different thicknesses (1.5 and 2 mm) and 8 mm diameters were calculated using a spectrophotometer (VITA Easyshade V, Zahnfabrik). A total of 36 Bifix QM and Grandio Flow samples were prepared at 100 μm thickness using a specific setup by polymerizing from the top of the blocks. Following immersion in distilled water at 37 °C for 24 h, luting materials were examined by Fourier Transform Infrared Spectroscopy for DC calculation. Data were analyzed using One-way ANOVA, Kruskal Wallis, Mann Whitney U, and Independent Samples t-tests (p < 0.05).</p><p><strong>Results: </strong>It was observed that, as the block thickness increased TP<sub>ab</sub>, TP<sub>00</sub>, and OP decreased, while CR increased. There was no significant difference between the DC of Bifix QM and Grandio Flow when 1.5 mm blocks were used in all groups (p > 0.05). DC of Grandio Flow was significantly higher than Bifix QM under 2 mm-IPS e.max CAD (p = 0.011).</p><p><strong>Conclusion: </strong>The translucency of the CAD-CAM blocks varies depending on their thickness. However, there was no significant difference in the DC of the luting materials depending on the block thickness. Further studies are needed on the use of flowable resin composites as luting material.</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"24 1","pages":"1384"},"PeriodicalIF":2.6000,"publicationDate":"2024-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11566408/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-024-05171-z","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: This in-vitro study aimed to evaluate the degree of conversion (DC) of dual-cured luting cement (Bifix QM, VOCO) and flowable composite (Grandio Flow, VOCO) under lithium disilicate glass-ceramic (IPS e.max CAD, Ivoclar Vivadent) and hybrid ceramic (Grandio Blocs, VOCO; Cerasmart, GC) CAD-CAM blocks with different thicknesses.

Materials and methods: Contrast ratio (CR), translucency (TPab, TP00), and opalescence (OP) parameters of 30 disc-shaped CAD-CAM blocks (n = 5) prepared with two different thicknesses (1.5 and 2 mm) and 8 mm diameters were calculated using a spectrophotometer (VITA Easyshade V, Zahnfabrik). A total of 36 Bifix QM and Grandio Flow samples were prepared at 100 μm thickness using a specific setup by polymerizing from the top of the blocks. Following immersion in distilled water at 37 °C for 24 h, luting materials were examined by Fourier Transform Infrared Spectroscopy for DC calculation. Data were analyzed using One-way ANOVA, Kruskal Wallis, Mann Whitney U, and Independent Samples t-tests (p < 0.05).

Results: It was observed that, as the block thickness increased TPab, TP00, and OP decreased, while CR increased. There was no significant difference between the DC of Bifix QM and Grandio Flow when 1.5 mm blocks were used in all groups (p > 0.05). DC of Grandio Flow was significantly higher than Bifix QM under 2 mm-IPS e.max CAD (p = 0.011).

Conclusion: The translucency of the CAD-CAM blocks varies depending on their thickness. However, there was no significant difference in the DC of the luting materials depending on the block thickness. Further studies are needed on the use of flowable resin composites as luting material.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
CAD-CAM 块体厚度和半透明度对搪瓷材料聚合的影响。
目的:这项体外研究旨在评估双固化胶结材料(Bifix QM,VOCO)和可流动复合材料(Grandio Flow,VOCO)在二硅酸锂玻璃陶瓷(IPS e.max CAD,Ivoclar Vivadent)和不同厚度的混合陶瓷(Grandio Blocs,VOCO;Cerasmart,GC)CAD-CAM块下的转化程度(DC):使用分光光度计(VITA Easyshade V,Zahnfabrik)计算了 30 个圆盘形 CAD-CAM 块(n = 5)的对比度(CR)、半透明度(TPab,TP00)和乳白度(OP)参数,这些块具有两种不同的厚度(1.5 毫米和 2 毫米)和 8 毫米的直径。使用特定的设置,从块的顶部开始聚合,总共制备了 36 个厚度为 100 μm 的 Bifix QM 和 Grandio Flow 样品。在 37 °C 的蒸馏水中浸泡 24 小时后,用傅立叶变换红外光谱法检测胶合材料,计算直流电。数据分析采用单因素方差分析、Kruskal Wallis 检验、Mann Whitney U 检验和独立样本 t 检验(P 结果):结果表明,随着区块厚度的增加,TPab、TP00 和 OP 下降,而 CR 上升。当所有组使用 1.5 毫米块时,Bifix QM 和 Grandio Flow 的直流电无明显差异(p > 0.05)。在 2 mm-IPS e.max CAD 下,Grandio Flow 的 DC 明显高于 Bifix QM(p = 0.011):结论:CAD-CAM 块体的半透明度因其厚度而异。结论:CAD-CAM 树脂块的透光度随其厚度的不同而变化,但搪瓷材料的直流电没有因树脂块厚度的不同而产生明显差异。对于使用可流动树脂复合材料作为衬垫材料还需要进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
BMC Oral Health
BMC Oral Health DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.90
自引率
6.90%
发文量
481
审稿时长
6-12 weeks
期刊介绍: BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.
期刊最新文献
Correction: The effect of root orientation on inferior alveolar nerve injury after extraction of impacted mandibular third molars based on propensity score‑matched analysis: a retrospective cohort study. Do randomised clinical trials on dental caries adopt Open Science practices? Effect of saliva on accuracy of digital dental implant transfer using two different materials of intraoral scan bodies with different exposed lengths. Regenerative endodontic therapy in immature teeth using photobiomodulation and photodynamic therapy; a histomorphological study in canine model. Salivary microbiome variations in type 2 diabetes mellitus patients with different stages of periodontitis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1