Kai Zhang, Guillaume Ducourthial, Taresh Sharan, Arvind Mohan, Jiasen Hou, Sudip Timilsina, Rongguang Liang, Frederic Louradour, Bryan Q Spring
{"title":"Video-rate two-photon microendoscopy using second harmonic resonance fiber scanning.","authors":"Kai Zhang, Guillaume Ducourthial, Taresh Sharan, Arvind Mohan, Jiasen Hou, Sudip Timilsina, Rongguang Liang, Frederic Louradour, Bryan Q Spring","doi":"10.1364/BOE.534399","DOIUrl":null,"url":null,"abstract":"<p><p>We present a 2.5-mm-diameter resonant fiber scanning two-photon microendoscope with a 30-mm long forward-viewing rigid probe tip that enables video-rate imaging (20 Hz frame rate) suitable for hand-held imaging of tissues without motion artifacts. Higher-order harmonic oscillation scanning techniques are developed to significantly increase the frame rate compared to prior published fiber scanning microendoscopy designs while maintaining the field-of-view (∼125 µm), the optical resolution (1.2 µm lateral and 10.9 µm axial resolution, full width at half maximum), and the spatial sampling (1250 circumferential pixels per spiral × 20 radial pixels over the diameter; 210 spirals per frame, ∼4 spiral samples per resolvable pixel) compared to a traditional scan using the fundamental resonance. 3D printed mounts were created to reduce the cost and simplify the fabrication for the fiber scanner without compromising performance or stability (<0.3 µm drift over 84 hours). A custom long-wavelength (∼1.08 µm) femtosecond fiber laser is coupled into several meters of fiber to realize a flexible, hand-held device for long-wavelength multiphoton microendoscopy.</p>","PeriodicalId":8969,"journal":{"name":"Biomedical optics express","volume":"15 11","pages":"6324-6339"},"PeriodicalIF":2.9000,"publicationDate":"2024-10-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11563328/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical optics express","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1364/BOE.534399","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
We present a 2.5-mm-diameter resonant fiber scanning two-photon microendoscope with a 30-mm long forward-viewing rigid probe tip that enables video-rate imaging (20 Hz frame rate) suitable for hand-held imaging of tissues without motion artifacts. Higher-order harmonic oscillation scanning techniques are developed to significantly increase the frame rate compared to prior published fiber scanning microendoscopy designs while maintaining the field-of-view (∼125 µm), the optical resolution (1.2 µm lateral and 10.9 µm axial resolution, full width at half maximum), and the spatial sampling (1250 circumferential pixels per spiral × 20 radial pixels over the diameter; 210 spirals per frame, ∼4 spiral samples per resolvable pixel) compared to a traditional scan using the fundamental resonance. 3D printed mounts were created to reduce the cost and simplify the fabrication for the fiber scanner without compromising performance or stability (<0.3 µm drift over 84 hours). A custom long-wavelength (∼1.08 µm) femtosecond fiber laser is coupled into several meters of fiber to realize a flexible, hand-held device for long-wavelength multiphoton microendoscopy.
期刊介绍:
The journal''s scope encompasses fundamental research, technology development, biomedical studies and clinical applications. BOEx focuses on the leading edge topics in the field, including:
Tissue optics and spectroscopy
Novel microscopies
Optical coherence tomography
Diffuse and fluorescence tomography
Photoacoustic and multimodal imaging
Molecular imaging and therapies
Nanophotonic biosensing
Optical biophysics/photobiology
Microfluidic optical devices
Vision research.