Redo-TAVI with the SAPIEN 3 valve in degenerated calcified CoreValve/Evolut explants.

IF 7.6 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS Eurointervention Pub Date : 2024-11-18 DOI:10.4244/EIJ-D-24-00619
David Meier, Anish Nigade, Althea Lai, Kyle Dorman, Hacina Gill, Shahnaz Javani, Mariama Akodad, David A Wood, Toby Rogers, Rishi Puri, Keith B Allen, Adnan K Chhatriwalla, Michael J Reardon, Gilbert H L Tang, Vinayak N Bapat, John G Webb, Shinichi Fukuhara, Stephanie L Sellers
{"title":"Redo-TAVI with the SAPIEN 3 valve in degenerated calcified CoreValve/Evolut explants.","authors":"David Meier, Anish Nigade, Althea Lai, Kyle Dorman, Hacina Gill, Shahnaz Javani, Mariama Akodad, David A Wood, Toby Rogers, Rishi Puri, Keith B Allen, Adnan K Chhatriwalla, Michael J Reardon, Gilbert H L Tang, Vinayak N Bapat, John G Webb, Shinichi Fukuhara, Stephanie L Sellers","doi":"10.4244/EIJ-D-24-00619","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Redo-transcatheter aortic valve implantation (TAVI) is the treatment of choice for failed transcatheter aortic valves. Currently, implantation of a SAPIEN 3 (S3) is indicated for redo-TAVI in degenerated CoreValve/Evolut (CV/EV) transcatheter aortic valves (TAVs) but is not well understood.</p><p><strong>Aims: </strong>We aimed to evaluate S3 function following implantation in explanted calcified CV/EV TAVs and to assess the impact of CV/EV pathology on redo-TAVI outcomes.</p><p><strong>Methods: </strong>Ex vivo hydrodynamic testing was performed per the International Organization for Standardization (ISO) 5840-3 standard on 4 S3 TAVs implanted at node 5 in calcified CV/EV explants. The mean gradient (MG), effective orifice area (EOA), peak velocity, regurgitant fraction (RF), geometric orifice area (GOA), leaflet overhang, leaflet pinwheeling, neoskirt height, and frame deformation were evaluated.</p><p><strong>Results: </strong>CV/EV explants were calcified and stenotic. Following S3 implantation, the MG and peak velocity decreased. As per the ISO standard, all S3 implants showed adequate EOA, and 3 out of 4 had an RF within the accepted value (<20%). CV/EV leaflet overhang ranged from 25-37%. Calcified leaflets remained stationary throughout the cardiac cycle (difference <9%) and were not pinned in a manner that constrained S3 systolic flow or appeared to prevent selective frame cannulation. The downstream CV/EV GOA was larger than the upstream S3 GOA during systole. S3 frame underexpansion was seen, resulting in leaflet pinwheeling (range 13-30%). Above the neoskirt, calcium protrusion was observed in contact with the S3 leaflets.</p><p><strong>Conclusions: </strong>S3 implantation at node 5 in calcified CV/EV valves resulted in satisfactory hydrodynamic performance in most configurations tested with stable leaflet overhang throughout the cardiac cycle. The long-term implications of S3 underexpansion, leaflet pinwheeling, and calcium protrusion require future studies.</p>","PeriodicalId":54378,"journal":{"name":"Eurointervention","volume":"20 22","pages":"1390-1404"},"PeriodicalIF":7.6000,"publicationDate":"2024-11-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11556406/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eurointervention","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4244/EIJ-D-24-00619","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Redo-transcatheter aortic valve implantation (TAVI) is the treatment of choice for failed transcatheter aortic valves. Currently, implantation of a SAPIEN 3 (S3) is indicated for redo-TAVI in degenerated CoreValve/Evolut (CV/EV) transcatheter aortic valves (TAVs) but is not well understood.

Aims: We aimed to evaluate S3 function following implantation in explanted calcified CV/EV TAVs and to assess the impact of CV/EV pathology on redo-TAVI outcomes.

Methods: Ex vivo hydrodynamic testing was performed per the International Organization for Standardization (ISO) 5840-3 standard on 4 S3 TAVs implanted at node 5 in calcified CV/EV explants. The mean gradient (MG), effective orifice area (EOA), peak velocity, regurgitant fraction (RF), geometric orifice area (GOA), leaflet overhang, leaflet pinwheeling, neoskirt height, and frame deformation were evaluated.

Results: CV/EV explants were calcified and stenotic. Following S3 implantation, the MG and peak velocity decreased. As per the ISO standard, all S3 implants showed adequate EOA, and 3 out of 4 had an RF within the accepted value (<20%). CV/EV leaflet overhang ranged from 25-37%. Calcified leaflets remained stationary throughout the cardiac cycle (difference <9%) and were not pinned in a manner that constrained S3 systolic flow or appeared to prevent selective frame cannulation. The downstream CV/EV GOA was larger than the upstream S3 GOA during systole. S3 frame underexpansion was seen, resulting in leaflet pinwheeling (range 13-30%). Above the neoskirt, calcium protrusion was observed in contact with the S3 leaflets.

Conclusions: S3 implantation at node 5 in calcified CV/EV valves resulted in satisfactory hydrodynamic performance in most configurations tested with stable leaflet overhang throughout the cardiac cycle. The long-term implications of S3 underexpansion, leaflet pinwheeling, and calcium protrusion require future studies.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用 SAPIEN 3 瓣膜对退行性钙化的 CoreValve/Evolut 外植体进行 Redo-TAVI。
背景:重做经导管主动脉瓣植入术(TAVI)是治疗失败的经导管主动脉瓣的首选方法。目前,SAPIEN 3(S3)植入术适用于变性的CoreValve/Evolut(CV/EV)经导管主动脉瓣(TAV)的再TAVI,但人们对它的了解并不多:根据国际标准化组织(ISO)5840-3标准,对植入钙化CV/EV第5节点的4个S3 TAV进行了体外流体力学测试。对平均梯度(MG)、有效孔面积(EOA)、峰值速度、反流分数(RF)、几何孔面积(GOA)、瓣叶悬垂、瓣叶针轮、新裙高度和框架变形进行了评估:结果:CV/EV外植体钙化、狭窄。植入 S3 后,MG 和峰值速度下降。根据 ISO 标准,所有 S3 植入体都显示出足够的 EOA,4 个中有 3 个的 RF 值在可接受的范围内(结论:S3 植入体在结节处钙化后,其 MG 和峰值速度均有所下降:在钙化的 CV/EV 瓣膜的第 5 节点植入 S3 后,在测试的大多数配置中都能获得令人满意的流体力学性能,并且在整个心动周期中都能保持稳定的瓣叶悬垂。S3扩张不足、瓣叶针轮和钙突的长期影响还需要进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Eurointervention
Eurointervention CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
10.30
自引率
4.80%
发文量
380
审稿时长
3-8 weeks
期刊介绍: EuroIntervention Journal is an international, English language, peer-reviewed journal whose aim is to create a community of high quality research and education in the field of percutaneous and surgical cardiovascular interventions.
期刊最新文献
Early outcomes of the novel Myval THV series compared to SAPIEN THV series and Evolut THV series in individuals with severe aortic stenosis. TAVI with the ACURATE neo2 in severe bicuspid aortic valve stenosis: the Neo2 BAV Registry. Development and validation of the D-PACE scoring system to predict delayed high-grade conduction disturbances after transcatheter aortic valve implantation. Feasibility of redo-TAVI in the self-expanding ACURATE neo2 valve: a computed tomography study. Long-term survival after TAVI in low-flow, low-gradient aortic valve stenosis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1