The NanoSIMS-HR: The Next Generation of High Spatial Resolution Dynamic SIMS

IF 6.7 1区 化学 Q1 CHEMISTRY, ANALYTICAL Analytical Chemistry Pub Date : 2024-11-26 DOI:10.1021/acs.analchem.4c03091
Peter K. Weber, Marc Debliqui, Céline Defouilloy, Xavier Mayali, Ming-Chang Liu, Rachel Hestrin, Jennifer Pett-Ridge, Rhona Stuart, Megan Morris, Christina Ramon, Danielle M. Jorgens, Reena Zalpuri, Laurent Arnoldi, Jérôme Farcy, Nicolas Saquet, Sarah Vitcher Fichou, Ludovic Renaud, Aurélien Thomen
{"title":"The NanoSIMS-HR: The Next Generation of High Spatial Resolution Dynamic SIMS","authors":"Peter K. Weber, Marc Debliqui, Céline Defouilloy, Xavier Mayali, Ming-Chang Liu, Rachel Hestrin, Jennifer Pett-Ridge, Rhona Stuart, Megan Morris, Christina Ramon, Danielle M. Jorgens, Reena Zalpuri, Laurent Arnoldi, Jérôme Farcy, Nicolas Saquet, Sarah Vitcher Fichou, Ludovic Renaud, Aurélien Thomen","doi":"10.1021/acs.analchem.4c03091","DOIUrl":null,"url":null,"abstract":"The high lateral resolution and sensitivity of the NanoSIMS 50 and 50L series of dynamic SIMS instruments have enabled numerous scientific advances over the past 25 years. Here, we report on the NanoSIMS-HR, the first major upgrade to the series, and analytical tests in a suite of sample types, including an aluminum sample containing silicon crystals, microalgae, and plant roots colonized with a symbiotic fungus. Significant improvements have been made in the Cs<sup>+</sup> ion source, high voltage (HV) control, stage reproducibility, and other aspects of the instrument that affect performance. The modified design of the NanoSIMS-HR thermal-ionization Cs<sup>+</sup> source enables a 5 pA primary ion beam to be focused into a 100 nm spot, a ∼2.5-fold increase compared to Cs<sup>+</sup> sources on previous instruments (∼2 pA at 100 nm). The brightness of the new Cs<sup>+</sup> source enables an ultimate lateral resolution as high as 30 nm and improved detection limits for a given analysis area. Sample stage movement accuracy is higher than 500 nm, enabling many-fold higher throughput automated analyses. With the new HV control, the primary ion beam impact energy can be reduced from 16 to 2 keV, which enables higher depth resolution during depth profiling (a 2-fold improvement), albeit with a 5-fold decrease in lateral resolution. In the NanoSIMS-HR, the secondary ion column and detection system are identical to those used in the previous series, and the isotopic analysis performance is as precise as in previous NanoSIMS instruments.","PeriodicalId":27,"journal":{"name":"Analytical Chemistry","volume":"27 1","pages":""},"PeriodicalIF":6.7000,"publicationDate":"2024-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acs.analchem.4c03091","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

The high lateral resolution and sensitivity of the NanoSIMS 50 and 50L series of dynamic SIMS instruments have enabled numerous scientific advances over the past 25 years. Here, we report on the NanoSIMS-HR, the first major upgrade to the series, and analytical tests in a suite of sample types, including an aluminum sample containing silicon crystals, microalgae, and plant roots colonized with a symbiotic fungus. Significant improvements have been made in the Cs+ ion source, high voltage (HV) control, stage reproducibility, and other aspects of the instrument that affect performance. The modified design of the NanoSIMS-HR thermal-ionization Cs+ source enables a 5 pA primary ion beam to be focused into a 100 nm spot, a ∼2.5-fold increase compared to Cs+ sources on previous instruments (∼2 pA at 100 nm). The brightness of the new Cs+ source enables an ultimate lateral resolution as high as 30 nm and improved detection limits for a given analysis area. Sample stage movement accuracy is higher than 500 nm, enabling many-fold higher throughput automated analyses. With the new HV control, the primary ion beam impact energy can be reduced from 16 to 2 keV, which enables higher depth resolution during depth profiling (a 2-fold improvement), albeit with a 5-fold decrease in lateral resolution. In the NanoSIMS-HR, the secondary ion column and detection system are identical to those used in the previous series, and the isotopic analysis performance is as precise as in previous NanoSIMS instruments.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
NanoSIMS-HR:新一代高空间分辨率动态 SIMS
过去 25 年来,NanoSIMS 50 和 50L 系列动态 SIMS 仪器的高横向分辨率和灵敏度推动了众多科学进步。在此,我们报告了 NanoSIMS-HR 的情况,这是该系列的首次重大升级,并对一系列样品类型进行了分析测试,包括含有硅晶体的铝样品、微藻和带有共生真菌的植物根。在 Cs+ 离子源、高压 (HV) 控制、阶段可重复性以及影响仪器性能的其他方面都有重大改进。经过改进设计的 NanoSIMS-HR 热电离 Cs+ 离子源可将 5 pA 的主离子束聚焦到 100 nm 的光斑中,与以前仪器上的 Cs+ 离子源(100 nm 处为 2 pA)相比,增加了 2.5 倍。新型 Cs+ 源的亮度使最终横向分辨率高达 30 nm,并提高了特定分析区域的检测限。样品台的移动精度高于 500 nm,使自动分析的吞吐量提高了许多倍。利用新型 HV 控制装置,主离子束的冲击能量可从 16 千伏降低到 2 千伏,从而在深度剖析过程中实现更高的深度分辨率(提高了 2 倍),尽管横向分辨率降低了 5 倍。在 NanoSIMS-HR 中,二次离子柱和检测系统与之前系列中使用的相同,同位素分析性能与之前的 NanoSIMS 仪器一样精确。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Analytical Chemistry
Analytical Chemistry 化学-分析化学
CiteScore
12.10
自引率
12.20%
发文量
1949
审稿时长
1.4 months
期刊介绍: Analytical Chemistry, a peer-reviewed research journal, focuses on disseminating new and original knowledge across all branches of analytical chemistry. Fundamental articles may explore general principles of chemical measurement science and need not directly address existing or potential analytical methodology. They can be entirely theoretical or report experimental results. Contributions may cover various phases of analytical operations, including sampling, bioanalysis, electrochemistry, mass spectrometry, microscale and nanoscale systems, environmental analysis, separations, spectroscopy, chemical reactions and selectivity, instrumentation, imaging, surface analysis, and data processing. Papers discussing known analytical methods should present a significant, original application of the method, a notable improvement, or results on an important analyte.
期刊最新文献
Bioluminescence Recovery after Photobleaching (BRAP) Enables Real-Time Imaging of Self-Repair Dynamics and Discovery of Modulators. Novel Ultrafast Sample-to-Answer Microfluidic Platform for Highly Sensitive On-Site Quantification of Avian Influenza Virus. Multistage Cascade-Hierarchical Nucleic Acid Amplification for Label-Free Ultrasensitive Electrochemical Sensing of Tumor-Associated Extracellular Vesicles. Machine Learning-Assisted DNA Origami Shape Sorting Using Fingerprinting Nanosensors and Feature Engineering. A Data-Driven Multifunctional Microfluidic Platform for in Vitro Safety Assessment of 5-Hydroxymethylfurfural.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1