Carbonised Typha tassel-modified enzymatic electrodes for ferrocene-mediated glucose biosensor and glucose/air biofuel cell applications

IF 4.9 2区 化学 Q1 CHEMISTRY, ANALYTICAL Microchemical Journal Pub Date : 2024-11-26 DOI:10.1016/j.microc.2024.112213
Şevki Furkan Küçükayar , Şevval Kaya , Veli Şimşek , Mustafa Oguzhan Caglayan , Zafer Üstündağ , Samet Şahin
{"title":"Carbonised Typha tassel-modified enzymatic electrodes for ferrocene-mediated glucose biosensor and glucose/air biofuel cell applications","authors":"Şevki Furkan Küçükayar ,&nbsp;Şevval Kaya ,&nbsp;Veli Şimşek ,&nbsp;Mustafa Oguzhan Caglayan ,&nbsp;Zafer Üstündağ ,&nbsp;Samet Şahin","doi":"10.1016/j.microc.2024.112213","DOIUrl":null,"url":null,"abstract":"<div><div>This study demonstrates the application of carbonised <em>Typha</em> tassel (CTT) in ferrocene-mediated enzymatic glucose biosensing and enzymatic biofuel cell (EnBFC) applications. <em>Typha</em> tassel was carbonised under an inert atmosphere to obtain conductive CTT which was then mixed with an effective electron transfer mediator, ferrocene (Fc) obtaining a redox-active electrode material. The successful immobilisation of the glucose oxidase (GOx) enzyme was performed on a CTT-Fc modified screen-printed electrode followed by a chitosan protective coating. The resulting enzymatic electrode was electrochemically characterised as a glucose biosensor with a working range of 0–10 mM and LOD and LOQ values of 0.19 mM and 0.56 mM, respectively. The developed glucose biosensor also showed good reproducibility and reusability with RSD% values of 6.68 % and 8.75 %, respectively. Furthermore, a real sample demonstration was performed using commercial jam samples with good recovery values. Finally, an EnBFC demonstration was performed using the enzymatic biosensor as an anode and a non-enzymatic cathode prepared using platinum black on gas diffusion carbon electrodes reaching a maximum power density of 3.6 µW cm<sup>−2</sup>. This study shows the promise of CTT as an alternative to conventional materials in enzymatic biosensor and bioelectronic applications as a suitable, cheap, and sustainable material.</div></div>","PeriodicalId":391,"journal":{"name":"Microchemical Journal","volume":"208 ","pages":"Article 112213"},"PeriodicalIF":4.9000,"publicationDate":"2024-11-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchemical Journal","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0026265X24023257","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study demonstrates the application of carbonised Typha tassel (CTT) in ferrocene-mediated enzymatic glucose biosensing and enzymatic biofuel cell (EnBFC) applications. Typha tassel was carbonised under an inert atmosphere to obtain conductive CTT which was then mixed with an effective electron transfer mediator, ferrocene (Fc) obtaining a redox-active electrode material. The successful immobilisation of the glucose oxidase (GOx) enzyme was performed on a CTT-Fc modified screen-printed electrode followed by a chitosan protective coating. The resulting enzymatic electrode was electrochemically characterised as a glucose biosensor with a working range of 0–10 mM and LOD and LOQ values of 0.19 mM and 0.56 mM, respectively. The developed glucose biosensor also showed good reproducibility and reusability with RSD% values of 6.68 % and 8.75 %, respectively. Furthermore, a real sample demonstration was performed using commercial jam samples with good recovery values. Finally, an EnBFC demonstration was performed using the enzymatic biosensor as an anode and a non-enzymatic cathode prepared using platinum black on gas diffusion carbon electrodes reaching a maximum power density of 3.6 µW cm−2. This study shows the promise of CTT as an alternative to conventional materials in enzymatic biosensor and bioelectronic applications as a suitable, cheap, and sustainable material.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于二茂铁介导的葡萄糖生物传感器和葡萄糖/空气生物燃料电池应用的碳化菇缨修饰酶促电极
本研究展示了碳化的香菇流苏(CTT)在二茂铁介导的酶促葡萄糖生物传感和酶促生物燃料电池(EnBFC)中的应用。在惰性气氛下碳化,得到导电CTT,然后与有效的电子转移介质二茂铁(Fc)混合,得到氧化还原活性电极材料。葡萄糖氧化酶(GOx)在CTT-Fc修饰的丝网印刷电极上成功固定,然后涂上壳聚糖保护涂层。所得酶促电极经电化学表征为葡萄糖生物传感器,工作范围为0-10 mM, LOD和LOQ值分别为0.19 mM和0.56 mM。该传感器具有良好的重现性和可重复使用性,RSD%分别为6.68%和8.75%。此外,使用具有良好采收率的商业果酱样品进行了实际样品演示。最后,在气体扩散碳电极上使用酶促生物传感器作为阳极和铂黑制备的非酶促阴极进行了EnBFC演示,其最大功率密度为3.6 μ W cm - 2。这项研究表明,CTT作为一种合适、廉价和可持续的材料,有望在酶生物传感器和生物电子应用中替代传统材料。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Microchemical Journal
Microchemical Journal 化学-分析化学
CiteScore
8.70
自引率
8.30%
发文量
1131
审稿时长
1.9 months
期刊介绍: The Microchemical Journal is a peer reviewed journal devoted to all aspects and phases of analytical chemistry and chemical analysis. The Microchemical Journal publishes articles which are at the forefront of modern analytical chemistry and cover innovations in the techniques to the finest possible limits. This includes fundamental aspects, instrumentation, new developments, innovative and novel methods and applications including environmental and clinical field. Traditional classical analytical methods such as spectrophotometry and titrimetry as well as established instrumentation methods such as flame and graphite furnace atomic absorption spectrometry, gas chromatography, and modified glassy or carbon electrode electrochemical methods will be considered, provided they show significant improvements and novelty compared to the established methods.
期刊最新文献
Editorial Board Handling non-linearities and pre-processing in multivariate calibration of vibrational spectra Novel carbon paste sensor modified with MWCNT and Ca-doped ZnO nanocomposite for therapeutic monitoring of Favipiravir in COVID-19 patients Search for the smallest switch-on, water soluble and a phase-sensitive fluorimetric probe for lipid membranes: N-aryl isoindolin-1-one core Simple and rapid paper-based colorimetric spot test for promethazine screening in recreational drug beverages and pharmaceuticals
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1