{"title":"Lesion Morphometry of the Pentaspline Pulsed Field Ablation Catheter: Understanding Catheter Pose, Rotation, and Dosing.","authors":"Keita Watanabe, Moritz Nies, Vivek Y Reddy, Jacob S Koruth","doi":"10.1161/CIRCEP.124.013208","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The pentaspline pulsed field ablation catheter achieves pulmonary vein isolation using 8 stacked, pose-specific applications with rotation. The morphology of pose-specific, single or double applications has not been described.</p><p><strong>Methods: </strong>One or 2 applications were delivered to select veins and discrete atrial and ventricular sites in 9 swine. General anesthesia with neuromuscular paralysis ensured a stable position. Preablation, postablation, and serial intraprocedural mappings were performed to characterize electrical vein isolation and dynamic voltage changes. Upon euthanize at 2 days (7 of 9 swine), hearts were subject to pathological examination.</p><p><strong>Results: </strong>Six superior vena cavae received single or double applications in basket pose without rotation. Despite incomplete dosing, acute electrical isolation occurred in 4 of 6 veins. None recovered conduction over 40 minutes, but all 3 isolated veins that were remapped at 2 days had reconnected. Lesions were linear (15-16 mm) with gaps and significantly wider with double versus single applications (8.2±2.8 versus 6.1±2.0 mm; <i>P</i>=0.02). Similar lesions, with acute isolation and subsequent reconnection, were observed in 3 of 4 ablated pulmonary veins. Double flower pose applications to the posterior atrium created wide (≈40×30 mm) confluent lesions, whereas single applications resulted in curvilinear lesions with variable gaps. Flower pose lesions (single or double) in the right ventricle were flower-shaped, linear with gaps, and with depths up to ≈5 mm.</p><p><strong>Conclusions: </strong>The pentaspline catheter in the basket pose creates perivenous linear lesions with gaps. Single applications in flower pose generate narrow linear lesions with variable gaps, whereas double applications result in wide, confluent lesions.</p>","PeriodicalId":10319,"journal":{"name":"Circulation. Arrhythmia and electrophysiology","volume":" ","pages":"e013208"},"PeriodicalIF":9.1000,"publicationDate":"2024-11-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Circulation. Arrhythmia and electrophysiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1161/CIRCEP.124.013208","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The pentaspline pulsed field ablation catheter achieves pulmonary vein isolation using 8 stacked, pose-specific applications with rotation. The morphology of pose-specific, single or double applications has not been described.

Methods: One or 2 applications were delivered to select veins and discrete atrial and ventricular sites in 9 swine. General anesthesia with neuromuscular paralysis ensured a stable position. Preablation, postablation, and serial intraprocedural mappings were performed to characterize electrical vein isolation and dynamic voltage changes. Upon euthanize at 2 days (7 of 9 swine), hearts were subject to pathological examination.

Results: Six superior vena cavae received single or double applications in basket pose without rotation. Despite incomplete dosing, acute electrical isolation occurred in 4 of 6 veins. None recovered conduction over 40 minutes, but all 3 isolated veins that were remapped at 2 days had reconnected. Lesions were linear (15-16 mm) with gaps and significantly wider with double versus single applications (8.2±2.8 versus 6.1±2.0 mm; P=0.02). Similar lesions, with acute isolation and subsequent reconnection, were observed in 3 of 4 ablated pulmonary veins. Double flower pose applications to the posterior atrium created wide (≈40×30 mm) confluent lesions, whereas single applications resulted in curvilinear lesions with variable gaps. Flower pose lesions (single or double) in the right ventricle were flower-shaped, linear with gaps, and with depths up to ≈5 mm.

Conclusions: The pentaspline catheter in the basket pose creates perivenous linear lesions with gaps. Single applications in flower pose generate narrow linear lesions with variable gaps, whereas double applications result in wide, confluent lesions.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
13.70
自引率
4.80%
发文量
187
审稿时长
4-8 weeks
期刊介绍: Circulation: Arrhythmia and Electrophysiology is a journal dedicated to the study and application of clinical cardiac electrophysiology. It covers a wide range of topics including the diagnosis and treatment of cardiac arrhythmias, as well as research in this field. The journal accepts various types of studies, including observational research, clinical trials, epidemiological studies, and advancements in translational research.
期刊最新文献
Pulsed Field Ablation of Paroxysmal Supraventricular Tachycardia: A Prospective Multicenter Single-Arm Study in China. Comparison of Procedural Outcomes of Lumenless Fixed-Helix Versus Stylet-Driven Extendable-Helix Lead Systems in Left Bundle Branch Pacing: COMPARE LBBP. Electrophysiological Phenotype-Genotype Study of Sustained Monomorphic Ventricular Tachycardia in Inherited, High Arrhythmic Risk, Left Ventricular Cardiomyopathy. Lesion Morphometry of the Pentaspline Pulsed Field Ablation Catheter: Understanding Catheter Pose, Rotation, and Dosing. Antithrombotic Strategies When Using Epicardial Carbon Dioxide Insufflation During Percutaneous Epicardial Access.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1