Application of intraoral scanning registration implant robot in dental implant surgery.

Nenghao Jin, Bo Qiao, Liang Zhu, Fanhao Meng, Quanquan Lin, Liangbo Li, Lejun Xing, Rui Zhao, Haizhong Zhang
{"title":"Application of intraoral scanning registration implant robot in dental implant surgery.","authors":"Nenghao Jin, Bo Qiao, Liang Zhu, Fanhao Meng, Quanquan Lin, Liangbo Li, Lejun Xing, Rui Zhao, Haizhong Zhang","doi":"10.7518/hxkq.2024.2024213","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This paper aims to investigate the application of intraoral scanning and cone beam computed tomography (CBCT) registration implant robot in dental implant surgery.</p><p><strong>Methods: </strong>The data of 40 cases with dental defect of robot-assisted implantation from November 2023 to May 2024 were retrospectively analyzed. Before the operation, the intraoral scan data and CBCT data of the positioning markers were automatically fused with the initial CBCT images, and the registration error was calculated. The average registration error of positioning markers was determined during the operation, and the implantation accuracy was analyzed after the operation.</p><p><strong>Results: </strong>The intraoral scan data and CBCT data of 40 patients with dental defect wearing positioning markers were successfully registered with the initial CBCT image, and the registration errors were (0.157±0.026) mm and (0.154±0.033) mm, respectively. Statistical analysis showed no statistical significance between them. The registration errors of the marker was (0.037 3±0.003 6) mm. A total of 55 implants were performed, and the total deviations of the implant point and the apical point were (0.78±0.41) and (0.89±0.28) mm, respectively. The transverse deviations of the implant point and the apical point were (0.44±0.36) and (0.58±0.25) mm, respectively. The depth deviations of the implant point and the apical point were (0.51±0.32) and (0.54±0.36) mm, respectively. The deviation of the implant angle was 1.24°±0.67°.</p><p><strong>Conclusions: </strong>The fusion technology based on intraoral scanning and CBCT registration can meet the accuracy requirements of preoperative registration of oral implant robots. The technology increases the choice of registration methods before robot-assisted dental implant surgery and reduces the multiple radiation exposuresof the patient.</p>","PeriodicalId":94028,"journal":{"name":"Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology","volume":"42 6","pages":"804-809"},"PeriodicalIF":0.0000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Hua xi kou qiang yi xue za zhi = Huaxi kouqiang yixue zazhi = West China journal of stomatology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7518/hxkq.2024.2024213","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: This paper aims to investigate the application of intraoral scanning and cone beam computed tomography (CBCT) registration implant robot in dental implant surgery.

Methods: The data of 40 cases with dental defect of robot-assisted implantation from November 2023 to May 2024 were retrospectively analyzed. Before the operation, the intraoral scan data and CBCT data of the positioning markers were automatically fused with the initial CBCT images, and the registration error was calculated. The average registration error of positioning markers was determined during the operation, and the implantation accuracy was analyzed after the operation.

Results: The intraoral scan data and CBCT data of 40 patients with dental defect wearing positioning markers were successfully registered with the initial CBCT image, and the registration errors were (0.157±0.026) mm and (0.154±0.033) mm, respectively. Statistical analysis showed no statistical significance between them. The registration errors of the marker was (0.037 3±0.003 6) mm. A total of 55 implants were performed, and the total deviations of the implant point and the apical point were (0.78±0.41) and (0.89±0.28) mm, respectively. The transverse deviations of the implant point and the apical point were (0.44±0.36) and (0.58±0.25) mm, respectively. The depth deviations of the implant point and the apical point were (0.51±0.32) and (0.54±0.36) mm, respectively. The deviation of the implant angle was 1.24°±0.67°.

Conclusions: The fusion technology based on intraoral scanning and CBCT registration can meet the accuracy requirements of preoperative registration of oral implant robots. The technology increases the choice of registration methods before robot-assisted dental implant surgery and reduces the multiple radiation exposuresof the patient.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Application of digital model of mixed reality dynamic tracking technique in oral and maxillofacial surgery: a basic research. Application of intraoral scanning registration implant robot in dental implant surgery. Application value of generative artificial intelligence in the field of stomatology. Assessment of the efficacy and analysis of prognostic factors of flap division for postoperative airway obstruction following posterior pharyngeal flap. Clinical study of the effect of the metal precrown restoration in the first deciduous molar on the composite resin filling in the second deciduous molar.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1