{"title":"Left ventricular pacing in a young African patient with a metallic tricuspid valve and infected epicardial leads: A case report.","authors":"M P Singhal, A Udyavar","doi":"10.4103/jpgm.jpgm_283_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>Tricuspid valve pathology is a relatively common anomaly. In patients with mechanical tricuspid valve replacement, implantation of a permanent pacemaker can be challenging due to the risk of valve damage, failure, and lead fracture associated with right ventricular endocardial leads. Epicardial leads may be an option, but they require a surgical procedure and are not preferred in patients with prior thoracotomy. This case report aims to demonstrate the safety and feasibility of left ventricular (LV) pacing via the coronary sinus (CS) in a 30-year-old young female with a mechanical tricuspid valve and infected epicardial leads. Due to the complications and contraindications of traditional approaches, Lead implantation via the CS was utilized. This method allowed for successful pacemaker implantation, demonstrating the feasibility and safety of LV pacing in such complex cases. The use of CS-guiding catheters and specialized leads facilitated effective cannulation and stable, reliable pacing, avoiding the need for further invasive surgeries.</p>","PeriodicalId":94105,"journal":{"name":"Journal of postgraduate medicine","volume":" ","pages":"245-248"},"PeriodicalIF":0.0000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11722709/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of postgraduate medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jpgm.jpgm_283_24","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/11/29 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract: Tricuspid valve pathology is a relatively common anomaly. In patients with mechanical tricuspid valve replacement, implantation of a permanent pacemaker can be challenging due to the risk of valve damage, failure, and lead fracture associated with right ventricular endocardial leads. Epicardial leads may be an option, but they require a surgical procedure and are not preferred in patients with prior thoracotomy. This case report aims to demonstrate the safety and feasibility of left ventricular (LV) pacing via the coronary sinus (CS) in a 30-year-old young female with a mechanical tricuspid valve and infected epicardial leads. Due to the complications and contraindications of traditional approaches, Lead implantation via the CS was utilized. This method allowed for successful pacemaker implantation, demonstrating the feasibility and safety of LV pacing in such complex cases. The use of CS-guiding catheters and specialized leads facilitated effective cannulation and stable, reliable pacing, avoiding the need for further invasive surgeries.