Preparation and characterisation of zirconia/hydroxyapatite bioactive composites as potential dental implants

IF 3.4 Q2 MATERIALS SCIENCE, MULTIDISCIPLINARY International Journal of Mechanical and Materials Engineering Pub Date : 2024-12-02 DOI:10.1186/s40712-024-00186-4
Zhongyuan Xing, Yongxin Pang, Eric Li, Jian Yong Zhang, Donglai Xu
{"title":"Preparation and characterisation of zirconia/hydroxyapatite bioactive composites as potential dental implants","authors":"Zhongyuan Xing,&nbsp;Yongxin Pang,&nbsp;Eric Li,&nbsp;Jian Yong Zhang,&nbsp;Donglai Xu","doi":"10.1186/s40712-024-00186-4","DOIUrl":null,"url":null,"abstract":"<div><p>In dental implants, zirconia is well-known as a crown material due to its excellent acid and base resistances and appearance close to natural teeth. In addition, its extraordinary mechanical properties render zirconia to be a potential candidate as an implant component of a whole implanted tooth, if its biocompatibility can be improved to promote adhesion to natural hard tissues. This study aims to enhance the bioactivity of zirconia with the aim of improving its integration with gum bone. Hydroxyapatite is the major component of natural bone and is thus selected as the modifier to improve the bioactivity of zirconia. A series of zirconia/hydroxyapatite composites with varied compositions were prepared under different conditions in order to find the optimal composites for the target application. Various analytical technologies and mechanical tests are employed to characterise the structure and properties of resultant composites. Results show that the component ratio and sintering temperature have a significant influence on the composite properties. An increase in hydroxyapatite component tends to enhance bioactivity but decline mechanical strength. Composites containing 10 wt% of hydroxyapatite maintain sufficient mechanical strength under the optimal sintering conditions whilst possessing excellent bioactivity, demonstrating that hydroxyapatite-modified zirconia has the potential as dental implant materials. Sintering results suggest that mechanical strength is obtained at 1400 °C for 2 h for the composite containing 10 wt% of hydroxyapatite.</p></div>","PeriodicalId":592,"journal":{"name":"International Journal of Mechanical and Materials Engineering","volume":"19 1","pages":""},"PeriodicalIF":3.4000,"publicationDate":"2024-12-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://jmsg.springeropen.com/counter/pdf/10.1186/s40712-024-00186-4","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Mechanical and Materials Engineering","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.1186/s40712-024-00186-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

In dental implants, zirconia is well-known as a crown material due to its excellent acid and base resistances and appearance close to natural teeth. In addition, its extraordinary mechanical properties render zirconia to be a potential candidate as an implant component of a whole implanted tooth, if its biocompatibility can be improved to promote adhesion to natural hard tissues. This study aims to enhance the bioactivity of zirconia with the aim of improving its integration with gum bone. Hydroxyapatite is the major component of natural bone and is thus selected as the modifier to improve the bioactivity of zirconia. A series of zirconia/hydroxyapatite composites with varied compositions were prepared under different conditions in order to find the optimal composites for the target application. Various analytical technologies and mechanical tests are employed to characterise the structure and properties of resultant composites. Results show that the component ratio and sintering temperature have a significant influence on the composite properties. An increase in hydroxyapatite component tends to enhance bioactivity but decline mechanical strength. Composites containing 10 wt% of hydroxyapatite maintain sufficient mechanical strength under the optimal sintering conditions whilst possessing excellent bioactivity, demonstrating that hydroxyapatite-modified zirconia has the potential as dental implant materials. Sintering results suggest that mechanical strength is obtained at 1400 °C for 2 h for the composite containing 10 wt% of hydroxyapatite.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
8.60
自引率
0.00%
发文量
1
审稿时长
13 weeks
期刊最新文献
Preparation and characterisation of zirconia/hydroxyapatite bioactive composites as potential dental implants Effect of feed rate during induction hardening on the hardening depth, microstructure, and wear properties of tool-grade steel work roll Influence of wood modification on parameter settings and treatment results in CO2 laser structuring of beech veneers Synthesis and characterization of titanium oxynitride catalyst via direct ammonia nitridation of titanium polyacrylate for oxygen reduction reaction Some studies on Abelmoschus esculentus (Indian Okra) fiber characteristics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1