Evaluating the potential for iodinated radiocontrast agents to interfere with ADAMTS13 activity testing via fluorescence resonance energy transfer methodology.

IF 2.3 4区 医学 Q2 PATHOLOGY American journal of clinical pathology Pub Date : 2024-12-05 DOI:10.1093/ajcp/aqae160
Jeremy W Jacobs, Melissa S Stuart, Julie I Tange, Rachel R Leger, Aneel A Ashrani, Dong Chen, Rajiv K Pruthi, Meera Sridharan, Jansen N Seheult
{"title":"Evaluating the potential for iodinated radiocontrast agents to interfere with ADAMTS13 activity testing via fluorescence resonance energy transfer methodology.","authors":"Jeremy W Jacobs, Melissa S Stuart, Julie I Tange, Rachel R Leger, Aneel A Ashrani, Dong Chen, Rajiv K Pruthi, Meera Sridharan, Jansen N Seheult","doi":"10.1093/ajcp/aqae160","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Fluorescence resonance energy transfer (FRET)-based ADAMTS13 activity assays are critical for the diagnosis of thrombotic thrombocytopenic purpura. However, these assays are susceptible to interference. As iodide has been suggested to interfere in laboratory testing via fluorophore quenching or promotion, we aimed to determine whether iodinated contrast (Omnipaque) interferes with the ATS-13 ADAMTS13 Activity Assay 2.0.</p><p><strong>Methods: </strong>We evaluated the excitation, emission, and absorbance spectrum of Omnipaque alone and spiked in patient plasma with known ADAMTS13 activity and ADAMTS13 activity on Omnipaque alone, an abnormal control of patient plasma previously observed to display elevated baseline relative fluorescent units, and variable concentrations of patient plasma with known ADAMTS13 activity spiked with Omnipaque.</p><p><strong>Results: </strong>No atypical fluorescent peaks were observed on any sample (Omnipaque alone or spiked in plasma) between 250 and 700 nm. There was no difference in the mean ADAMTS13 activity among the various concentrations of plasma spiked with Omnipaque or plasma spiked with saline.</p><p><strong>Conclusions: </strong>Iodinated contrast does not appear to interfere-either via spectral overlap of the fluorophore or through physiologic inhibition of the ADAMTS13 enzyme-with ADAMTS13 activity FRET-based assays based on the findings from this in vitro analysis. Delaying sample collection for ADAMTS13 activity testing from suspected patients with thrombotic thrombocytopenic purpura following administration of iodinated radiocontrast agents is not necessary, and recent contrast administration should not yield erroneous ADAMTS13 activity results.</p>","PeriodicalId":7506,"journal":{"name":"American journal of clinical pathology","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-12-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of clinical pathology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ajcp/aqae160","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PATHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Fluorescence resonance energy transfer (FRET)-based ADAMTS13 activity assays are critical for the diagnosis of thrombotic thrombocytopenic purpura. However, these assays are susceptible to interference. As iodide has been suggested to interfere in laboratory testing via fluorophore quenching or promotion, we aimed to determine whether iodinated contrast (Omnipaque) interferes with the ATS-13 ADAMTS13 Activity Assay 2.0.

Methods: We evaluated the excitation, emission, and absorbance spectrum of Omnipaque alone and spiked in patient plasma with known ADAMTS13 activity and ADAMTS13 activity on Omnipaque alone, an abnormal control of patient plasma previously observed to display elevated baseline relative fluorescent units, and variable concentrations of patient plasma with known ADAMTS13 activity spiked with Omnipaque.

Results: No atypical fluorescent peaks were observed on any sample (Omnipaque alone or spiked in plasma) between 250 and 700 nm. There was no difference in the mean ADAMTS13 activity among the various concentrations of plasma spiked with Omnipaque or plasma spiked with saline.

Conclusions: Iodinated contrast does not appear to interfere-either via spectral overlap of the fluorophore or through physiologic inhibition of the ADAMTS13 enzyme-with ADAMTS13 activity FRET-based assays based on the findings from this in vitro analysis. Delaying sample collection for ADAMTS13 activity testing from suspected patients with thrombotic thrombocytopenic purpura following administration of iodinated radiocontrast agents is not necessary, and recent contrast administration should not yield erroneous ADAMTS13 activity results.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过荧光共振能量转移方法评估碘化放射造影剂干扰 ADAMTS13 活性检测的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
7.70
自引率
2.90%
发文量
367
审稿时长
3-6 weeks
期刊介绍: The American Journal of Clinical Pathology (AJCP) is the official journal of the American Society for Clinical Pathology and the Academy of Clinical Laboratory Physicians and Scientists. It is a leading international journal for publication of articles concerning novel anatomic pathology and laboratory medicine observations on human disease. AJCP emphasizes articles that focus on the application of evolving technologies for the diagnosis and characterization of diseases and conditions, as well as those that have a direct link toward improving patient care.
期刊最新文献
External quality assessment in African clinical laboratories: A systematic review and meta-analysis. Comparative evaluation of PD-L1 expression and tumor immune microenvironment in molecular subtypes of muscle-invasive bladder cancer and its correlation with survival outcomes. Like, share, and follow!: Usage of social media by pathology residency programs in the COVID-19 era. Reply to "Extragenital self-collection testing for gonorrhea and chlamydia: a feasibility study for expanding STI screening in the Veterans Health Administration". Self-collection testing for gonorrhea and chlamydia: Correspondence.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1