Charging and Discharging of Poly(m-aminophenylboronic Acid) Doped with Phytic Acid for Enzyme-Free Real-Time Monitoring of Human Sweat Lactate

IF 3.7 3区 化学 Q2 CHEMISTRY, MULTIDISCIPLINARY ACS Omega Pub Date : 2024-12-08 DOI:10.1021/acsomega.4c0667110.1021/acsomega.4c06671
Ryujiro Kishi, Shoichi Nishitani, Hiroyuki Kudo and Toshiya Sakata*, 
{"title":"Charging and Discharging of Poly(m-aminophenylboronic Acid) Doped with Phytic Acid for Enzyme-Free Real-Time Monitoring of Human Sweat Lactate","authors":"Ryujiro Kishi,&nbsp;Shoichi Nishitani,&nbsp;Hiroyuki Kudo and Toshiya Sakata*,&nbsp;","doi":"10.1021/acsomega.4c0667110.1021/acsomega.4c06671","DOIUrl":null,"url":null,"abstract":"<p >In this study, we realized a real-time and enzyme-free measurement of lactate in sweat in the same way as an enzyme-based amperometric method. A conductive polymer, which is based on polyaniline (PANI), was strongly coated on a glassy carbon electrode as a poly <i>m</i>-aminophenylboronic acid (PANI–PBA) membrane by drop-casting, which is a convenient method, owing to adhesive phytic acid (PA) molecules with negative charges included as a dopant. This polymer membrane had a functional structure with PBA in the PANI main chain, which expectedly induced electrical charges upon diol binding to lactate, owing to the formation of deprotonated boronate esters with negative charges. This indicates that PBA served as the self-dopant and as the site of binding to lactate. On the basis of the fundamental electrochemical characteristics such as the membrane resistance, the change in the current density of the PA-doped PANI–PBA electrode was quantitatively monitored with the change in lactate concentration from 1 to 300 mM under acidic conditions in real time, considering pH and interfering substances in sweat. Moreover, the sweat lactate concentration was determined to be ca. 60 mM using the PA-doped PANI–PBA electrode in a microfluidic system in measurements using sweat samples collected during exercise load. A change in current density induced a change in the density of charges in the capacitive PA-doped PANI–PBA membrane. This means that the detection mechanism for the change in the lactate concentration in sweat was based on repeated charging and discharging in the PA-doped PANI–PBA electrode.</p>","PeriodicalId":22,"journal":{"name":"ACS Omega","volume":"9 50","pages":"49368–49376 49368–49376"},"PeriodicalIF":3.7000,"publicationDate":"2024-12-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.acs.org/doi/epdf/10.1021/acsomega.4c06671","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Omega","FirstCategoryId":"92","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acsomega.4c06671","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

In this study, we realized a real-time and enzyme-free measurement of lactate in sweat in the same way as an enzyme-based amperometric method. A conductive polymer, which is based on polyaniline (PANI), was strongly coated on a glassy carbon electrode as a poly m-aminophenylboronic acid (PANI–PBA) membrane by drop-casting, which is a convenient method, owing to adhesive phytic acid (PA) molecules with negative charges included as a dopant. This polymer membrane had a functional structure with PBA in the PANI main chain, which expectedly induced electrical charges upon diol binding to lactate, owing to the formation of deprotonated boronate esters with negative charges. This indicates that PBA served as the self-dopant and as the site of binding to lactate. On the basis of the fundamental electrochemical characteristics such as the membrane resistance, the change in the current density of the PA-doped PANI–PBA electrode was quantitatively monitored with the change in lactate concentration from 1 to 300 mM under acidic conditions in real time, considering pH and interfering substances in sweat. Moreover, the sweat lactate concentration was determined to be ca. 60 mM using the PA-doped PANI–PBA electrode in a microfluidic system in measurements using sweat samples collected during exercise load. A change in current density induced a change in the density of charges in the capacitive PA-doped PANI–PBA membrane. This means that the detection mechanism for the change in the lactate concentration in sweat was based on repeated charging and discharging in the PA-doped PANI–PBA electrode.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
掺杂植酸的聚(间氨基苯硼酸)的充电和放电用于人体汗液乳酸盐的无酶实时监测
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ACS Omega
ACS Omega Chemical Engineering-General Chemical Engineering
CiteScore
6.60
自引率
4.90%
发文量
3945
审稿时长
2.4 months
期刊介绍: ACS Omega is an open-access global publication for scientific articles that describe new findings in chemistry and interfacing areas of science, without any perceived evaluation of immediate impact.
期刊最新文献
Issue Publication Information Issue Editorial Masthead Issue Editorial Masthead Issue Publication Information Tumor-Targeted Magnetic Micelles for Magnetic Resonance Imaging, Drug Delivery, and Overcoming Multidrug Resistance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1