Volume kinetic analysis of 2 crystalloid fluid bolus rates in anesthetized cats.

Pen-Ting Liao, William Raivs, Stuart Clark-Price, Katherine Gerken, Sue Duran
{"title":"Volume kinetic analysis of 2 crystalloid fluid bolus rates in anesthetized cats.","authors":"Pen-Ting Liao, William Raivs, Stuart Clark-Price, Katherine Gerken, Sue Duran","doi":"10.1111/vec.13449","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate the volume kinetic between 2 crystalloid fluid bolus rates in anesthetized cats.</p><p><strong>Design: </strong>Prospective, randomized, dose-response study.</p><p><strong>Setting: </strong>University laboratory.</p><p><strong>Animals: </strong>Ten convenience-sample, purpose-bred domestic shorthair and medium hair cats.</p><p><strong>Interventions: </strong>Intravenous 20 mL/kg balanced crystalloid fluid over 10 (G10) or 40 (G40) minutes under anesthesia in a randomized order with at least a 5-day washout period.</p><p><strong>Measurements and main results: </strong>Serial measurements of hemoglobin (Hb) concentration and PCV were performed up to 60 minutes after conclusion of the fluid bolus. Plasma dilution was calculated with the Hb dilution method and fitted to a 2-compartment microconstant kinetic model using nonlinear mixed-effect models. The apparent central plasma volume (V<sub>c</sub>) was similar between the 2 groups (G10: 81.2 ± 23.8 mL/kg and G40: 78.8 ± 10.2 mL/kg). The apparent peripheral volume (V<sub>p</sub>) of G10 (4.81E+8 ± 2.66E+8 mL/kg) was twice that of G40 (2.36E+8 ± 6.44E+7 mL/kg). The rate constant from V<sub>c</sub> to V<sub>p</sub> (K<sub>12</sub>) of G10 (0.057 ± 0.0196/min) was almost twice that of G40 (0.0302 ± 0.00807/min). The elimination constant of G10 (0.0113 ± 0.00672/min) was almost twice that of G40 (0.00534 ± 0.00279/min). The peak plasma expansion was similar between G10 and G40 (20.7 ± 1.9 and 19.1 ± 5.1 mL/kg). Area under the curve for plasma dilution versus time of the first 90 minutes from the beginning of the boluses was not statistically different between G10 and G40.</p><p><strong>Conclusions: </strong>The volume expansion over time was not different likely due to the slow elimination. The plasma dilution to crystalloid bolus between subjects is varied in anesthetized cats. Clinicians should consider the slow elimination and return of crystalloid fluid from the V<sub>p</sub> to V<sub>c</sub> when prescribing fluid therapy in anesthetized cats.</p>","PeriodicalId":74015,"journal":{"name":"Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001)","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of veterinary emergency and critical care (San Antonio, Tex. : 2001)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1111/vec.13449","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To investigate the volume kinetic between 2 crystalloid fluid bolus rates in anesthetized cats.

Design: Prospective, randomized, dose-response study.

Setting: University laboratory.

Animals: Ten convenience-sample, purpose-bred domestic shorthair and medium hair cats.

Interventions: Intravenous 20 mL/kg balanced crystalloid fluid over 10 (G10) or 40 (G40) minutes under anesthesia in a randomized order with at least a 5-day washout period.

Measurements and main results: Serial measurements of hemoglobin (Hb) concentration and PCV were performed up to 60 minutes after conclusion of the fluid bolus. Plasma dilution was calculated with the Hb dilution method and fitted to a 2-compartment microconstant kinetic model using nonlinear mixed-effect models. The apparent central plasma volume (Vc) was similar between the 2 groups (G10: 81.2 ± 23.8 mL/kg and G40: 78.8 ± 10.2 mL/kg). The apparent peripheral volume (Vp) of G10 (4.81E+8 ± 2.66E+8 mL/kg) was twice that of G40 (2.36E+8 ± 6.44E+7 mL/kg). The rate constant from Vc to Vp (K12) of G10 (0.057 ± 0.0196/min) was almost twice that of G40 (0.0302 ± 0.00807/min). The elimination constant of G10 (0.0113 ± 0.00672/min) was almost twice that of G40 (0.00534 ± 0.00279/min). The peak plasma expansion was similar between G10 and G40 (20.7 ± 1.9 and 19.1 ± 5.1 mL/kg). Area under the curve for plasma dilution versus time of the first 90 minutes from the beginning of the boluses was not statistically different between G10 and G40.

Conclusions: The volume expansion over time was not different likely due to the slow elimination. The plasma dilution to crystalloid bolus between subjects is varied in anesthetized cats. Clinicians should consider the slow elimination and return of crystalloid fluid from the Vp to Vc when prescribing fluid therapy in anesthetized cats.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
麻醉猫2种晶体液体丸率的体积动力学分析。
目的:研究麻醉猫两种晶体液体剂量的体积动力学。设计:前瞻性、随机、剂量反应研究。环境:大学实验室。动物:10只方便样本,专门饲养的家养短毛猫和中毛猫。干预措施:麻醉下按随机顺序静脉注射20 mL/kg平衡晶体液,麻醉时间为10 (G10)或40 (G40)分钟,至少有5天的洗脱期。测量和主要结果:连续测量血红蛋白(Hb)浓度和PCV,直至液体丸结束后60分钟。血浆稀释度采用血红蛋白稀释法计算,并采用非线性混合效应模型拟合为2室微常数动力学模型。两组的视中心血浆容量(Vc)相近,G10组为81.2±23.8 mL/kg, G40组为78.8±10.2 mL/kg。G10的表观外周体积(Vp) (4.81E+8±2.66E+8 mL/kg)是G40 (2.36E+8±6.44E+7 mL/kg)的2倍。G10从Vc到Vp (K12)的速率常数(0.057±0.0196/min)几乎是G40(0.0302±0.00807/min)的2倍。G10的消除常数(0.0113±0.00672/min)几乎是G40(0.00534±0.00279/min)的2倍。G10和G40的峰值血浆膨胀率相似(20.7±1.9和19.1±5.1 mL/kg)。血浆稀释曲线下面积与注射开始后90分钟的时间在G10和G40之间无统计学差异。结论:随着时间的推移,由于消除缓慢,体积膨胀可能没有差异。在被麻醉的猫中,受试者之间的血浆稀释到晶体丸的比例是不同的。在给麻醉猫开液体治疗处方时,临床医生应该考虑到晶体液体从Vp到Vc的缓慢消除和返回。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Abdominal fluid score as a predictor of transfusion needs and outcome in cats following trauma. A novel approach to decannulation of a tracheostomy tube using a 1-way speaking valve after upper airway trauma in 2 dogs. An exploratory study on the effect of rescuer team size on basic and advanced life support technical skills in a high-fidelity simulation of canine cardiopulmonary arrest. Assessment of shock index in healthy cats and in cats presenting to an emergency room with shock. Determination of reference intervals of venous blood gas and acid-base parameters in clinically healthy awake cats.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1