Interim Results of Rigicon Penile Prosthesis Implantation in a Single Center: The Largest Series in Türkiye.

0 UROLOGY & NEPHROLOGY Urology research & practice Pub Date : 2025-01-03 DOI:10.5152/tud.2025.24122
Muhammet İhsan Karaman, Rasim Güzel, Duygu Kirkik, Orhan Koca
{"title":"Interim Results of Rigicon Penile Prosthesis Implantation in a Single Center: The Largest Series in Türkiye.","authors":"Muhammet İhsan Karaman, Rasim Güzel, Duygu Kirkik, Orhan Koca","doi":"10.5152/tud.2025.24122","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To analyze data from patient information forms (PIFs) submitted to the manufacturer of a new 3-piece inflatable penile prosthesis (IPP), the Rigicon Infla10® , to summarize interim outcomes of 250 implantations in a single center, which is the largest series in Türkiye.</p><p><strong>Methods: </strong>A retrospective review of PIFs from 250 patients implanted with the IPP between January 2021 and December 2023 was performed to assess patient characteristics, surgical data, device durability, patient satisfaction, and rates of reoperation for any reason.</p><p><strong>Results: </strong>The mean ± SD (range) follow-up was 21.2 ± 8.7 (6-36) months and the mean ± SD patient age was 56.2 ± 9.1 years. The average surgical time was 47 minutes. Of the total, 2.4% of devices required removal or revision. Mechanical failure of the device was reported in 3 patients (1.2%). One patient (0.4%) required revision for noise during pumping. Two patients (0.8%) requested device removal because of dissatisfaction. No infections were observed in this series. A total of 97.6% of the Rigicon Infla10® devices were free from explant or revision. The satisfaction rate based on a single question asked to the patient by the surgeon 6 months after surgery was 98.4%.</p><p><strong>Conclusion: </strong>All Rigicon Infla10® IPPs implanted in the center prior to January 2024 were included in the retrospective analysis of volunteered PIFs. Initial durability from reoperation was demonstrated to be superior compared to other contemporary devices. Additionally, high satisfaction with treatment outcomes was reported by 92.4% of patients.</p>","PeriodicalId":101337,"journal":{"name":"Urology research & practice","volume":"50 4","pages":"234-239"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Urology research & practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5152/tud.2025.24122","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"UROLOGY & NEPHROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To analyze data from patient information forms (PIFs) submitted to the manufacturer of a new 3-piece inflatable penile prosthesis (IPP), the Rigicon Infla10® , to summarize interim outcomes of 250 implantations in a single center, which is the largest series in Türkiye.

Methods: A retrospective review of PIFs from 250 patients implanted with the IPP between January 2021 and December 2023 was performed to assess patient characteristics, surgical data, device durability, patient satisfaction, and rates of reoperation for any reason.

Results: The mean ± SD (range) follow-up was 21.2 ± 8.7 (6-36) months and the mean ± SD patient age was 56.2 ± 9.1 years. The average surgical time was 47 minutes. Of the total, 2.4% of devices required removal or revision. Mechanical failure of the device was reported in 3 patients (1.2%). One patient (0.4%) required revision for noise during pumping. Two patients (0.8%) requested device removal because of dissatisfaction. No infections were observed in this series. A total of 97.6% of the Rigicon Infla10® devices were free from explant or revision. The satisfaction rate based on a single question asked to the patient by the surgeon 6 months after surgery was 98.4%.

Conclusion: All Rigicon Infla10® IPPs implanted in the center prior to January 2024 were included in the retrospective analysis of volunteered PIFs. Initial durability from reoperation was demonstrated to be superior compared to other contemporary devices. Additionally, high satisfaction with treatment outcomes was reported by 92.4% of patients.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.60
自引率
0.00%
发文量
0
期刊最新文献
Comparison of Temperature Changes Between Holmium-YAG Laser and Thulium Fiber Laser in an In Vitro Setting. Concurrent Renorrhaphy During Renal Mass Excision in Laparoscopic Nephron-Sparing Surgery: A Novel Surgical Technique. Factors Affecting the Presence of Renal Cortical Cysts in Kidney Donors. Interim Results of Rigicon Penile Prosthesis Implantation in a Single Center: The Largest Series in Türkiye. Meta Analysis of Efficacy and Safety of Prostate Biopsy: A Comparison Between Transperineal and Transrectal Approach.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1