Development and assessment of a prototype of an interproximal image receptor-holding device for use in pediatric dentistry.

IF 2.9 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Dento maxillo facial radiology Pub Date : 2025-02-05 DOI:10.1093/dmfr/twaf009
Thaís Santos Cerqueira Ocampo, Caio de Alencar-Palha, Deivi Antonio Cascante-Sequeira, Marcela Tarosso Réa, Deborah Queiroz Freitas, Francisco Haiter-Neto
{"title":"Development and assessment of a prototype of an interproximal image receptor-holding device for use in pediatric dentistry.","authors":"Thaís Santos Cerqueira Ocampo, Caio de Alencar-Palha, Deivi Antonio Cascante-Sequeira, Marcela Tarosso Réa, Deborah Queiroz Freitas, Francisco Haiter-Neto","doi":"10.1093/dmfr/twaf009","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To develop and test a prototype for interproximal radiography positioning intended for pediatric dentistry and compare the technical quality of image receptor-holding devices (IRHD) commonly used in clinical practice.</p><p><strong>Methods: </strong>Six prototypes, with three wedge dimensions (0.5 mm, 1 mm, and 2 mm) in upper and lower positions on the bitewing surface were compared regarding their capacity to acquire interproximal radiographs without overlapping surfaces with other IRHDs: RinnXCPTM, Hawe KerrTM, and Cone Indicator. Fifteen graduate students obtained images of deciduous molars in a child's skull and mandible. The chi-square and Fisher's exact tests were employed to analyze significant differences in the number of repetitions and failures in obtaining correct images. A one-way ANOVA assessed the difference between the mean times required for image acquisition according to each IRHD, adopting a significance level of 5%.</p><p><strong>Results: </strong>The effectiveness of the tested devices, evaluated by the number of correct and incorrect acquisitions using Fisher's exact test, revealed a p-value of 0.057. The ANOVA demonstrated statistically significant differences in the mean acquisition times (p < 0.0000). The upper and lower wedge prototypes 2 mm performed better in acquiring only one radiograph (76.7%) and took less time to execute the technique (1.17 min and 1.12 min, respectively).</p><p><strong>Conclusion: </strong>The prototypes showed comparable performance to alternative IRHDs but provided advantages in time efficiency and radiation exposure.</p>","PeriodicalId":11261,"journal":{"name":"Dento maxillo facial radiology","volume":" ","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2025-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dento maxillo facial radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/dmfr/twaf009","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To develop and test a prototype for interproximal radiography positioning intended for pediatric dentistry and compare the technical quality of image receptor-holding devices (IRHD) commonly used in clinical practice.

Methods: Six prototypes, with three wedge dimensions (0.5 mm, 1 mm, and 2 mm) in upper and lower positions on the bitewing surface were compared regarding their capacity to acquire interproximal radiographs without overlapping surfaces with other IRHDs: RinnXCPTM, Hawe KerrTM, and Cone Indicator. Fifteen graduate students obtained images of deciduous molars in a child's skull and mandible. The chi-square and Fisher's exact tests were employed to analyze significant differences in the number of repetitions and failures in obtaining correct images. A one-way ANOVA assessed the difference between the mean times required for image acquisition according to each IRHD, adopting a significance level of 5%.

Results: The effectiveness of the tested devices, evaluated by the number of correct and incorrect acquisitions using Fisher's exact test, revealed a p-value of 0.057. The ANOVA demonstrated statistically significant differences in the mean acquisition times (p < 0.0000). The upper and lower wedge prototypes 2 mm performed better in acquiring only one radiograph (76.7%) and took less time to execute the technique (1.17 min and 1.12 min, respectively).

Conclusion: The prototypes showed comparable performance to alternative IRHDs but provided advantages in time efficiency and radiation exposure.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
5.60
自引率
9.10%
发文量
65
审稿时长
4-8 weeks
期刊介绍: Dentomaxillofacial Radiology (DMFR) is the journal of the International Association of Dentomaxillofacial Radiology (IADMFR) and covers the closely related fields of oral radiology and head and neck imaging. Established in 1972, DMFR is a key resource keeping dentists, radiologists and clinicians and scientists with an interest in Head and Neck imaging abreast of important research and developments in oral and maxillofacial radiology. The DMFR editorial board features a panel of international experts including Editor-in-Chief Professor Ralf Schulze. Our editorial board provide their expertise and guidance in shaping the content and direction of the journal. Quick Facts: - 2015 Impact Factor - 1.919 - Receipt to first decision - average of 3 weeks - Acceptance to online publication - average of 3 weeks - Open access option - ISSN: 0250-832X - eISSN: 1476-542X
期刊最新文献
Bone quality assessment around dental implants in cone-beam computed tomography images: effect of scan mode and metal artefact reduction tool. Deep learning-based segmentation of the mandibular canals in cone beam computed tomography reaches human level performance. Skull joints assessed via CT for age estimation-a systematic review. Development and assessment of a prototype of an interproximal image receptor-holding device for use in pediatric dentistry. Advancing periodontal diagnosis: Harnessing advanced artificial intelligence for patterns of periodontal bone loss in cone beam computed tomography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1