Reference ranges ("normal values") for cardiovascular magnetic resonance (CMR) in adults and children: 2025 update.

IF 4.2 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS Journal of Cardiovascular Magnetic Resonance Pub Date : 2025-02-04 DOI:10.1016/j.jocmr.2025.101853
Nadine Kawel-Boehm, Scott J Hetzel, Bharath Ambale-Venkatesh, Gabriella Captur, Calvin Wl Chin, Christopher J François, Michael Jerosch-Herold, Judy M Luu, Zahra Raisi-Estabragh, Jitka Starekova, Michael Taylor, Max van Hout, David A Bluemke
{"title":"Reference ranges (\"normal values\") for cardiovascular magnetic resonance (CMR) in adults and children: 2025 update.","authors":"Nadine Kawel-Boehm, Scott J Hetzel, Bharath Ambale-Venkatesh, Gabriella Captur, Calvin Wl Chin, Christopher J François, Michael Jerosch-Herold, Judy M Luu, Zahra Raisi-Estabragh, Jitka Starekova, Michael Taylor, Max van Hout, David A Bluemke","doi":"10.1016/j.jocmr.2025.101853","DOIUrl":null,"url":null,"abstract":"<p><p>Quantitative assessment of morphological and functional cardiac parameters by cardiovascular magnetic resonance (CMR) is essential for research and routine clinical practice. Beyond established parameters of chamber size and function, tissue properties such as relaxation times play an increasing role. Normal reference ranges are required for interpretation of results obtained by quantitative CMR. Since the last publication of the \"normal value review\" in 2020 many new publications related to CMR reference values have been published, which were integrated in this update. The larger sample size provides greater statistical confidence in the estimates of upper and lower limits, and enables further partitioning, e.g., by age and ethnicity for several parameters. Previous topics were expanded by new sections.</p>","PeriodicalId":15221,"journal":{"name":"Journal of Cardiovascular Magnetic Resonance","volume":" ","pages":"101853"},"PeriodicalIF":4.2000,"publicationDate":"2025-02-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Magnetic Resonance","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jocmr.2025.101853","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Quantitative assessment of morphological and functional cardiac parameters by cardiovascular magnetic resonance (CMR) is essential for research and routine clinical practice. Beyond established parameters of chamber size and function, tissue properties such as relaxation times play an increasing role. Normal reference ranges are required for interpretation of results obtained by quantitative CMR. Since the last publication of the "normal value review" in 2020 many new publications related to CMR reference values have been published, which were integrated in this update. The larger sample size provides greater statistical confidence in the estimates of upper and lower limits, and enables further partitioning, e.g., by age and ethnicity for several parameters. Previous topics were expanded by new sections.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
10.90
自引率
12.50%
发文量
61
审稿时长
6-12 weeks
期刊介绍: Journal of Cardiovascular Magnetic Resonance (JCMR) publishes high-quality articles on all aspects of basic, translational and clinical research on the design, development, manufacture, and evaluation of cardiovascular magnetic resonance (CMR) methods applied to the cardiovascular system. Topical areas include, but are not limited to: New applications of magnetic resonance to improve the diagnostic strategies, risk stratification, characterization and management of diseases affecting the cardiovascular system. New methods to enhance or accelerate image acquisition and data analysis. Results of multicenter, or larger single-center studies that provide insight into the utility of CMR. Basic biological perceptions derived by CMR methods.
期刊最新文献
Multiresolution comparison of fetal real-time and CINE MRI at 0.55T. A comprehensive evaluation of the left atrium using CMR. Exploring the limits of scan time reduction for ferumoxytol-enhanced whole-heart angiography in congenital heart disease patients. Reference ranges ("normal values") for cardiovascular magnetic resonance (CMR) in adults and children: 2025 update. Non-invasive estimation of left ventricular chamber stiffness using cardiovascular magnetic resonance and echocardiography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1