{"title":"Adverse Events Associated With Female External Urinary Collection Devices.","authors":"Mahgol Golshani, Aaron Tverye, Taylor Bate, Jennifer T Anger, Colby P Souders","doi":"10.1097/SPV.0000000000001656","DOIUrl":null,"url":null,"abstract":"<p><strong>Importance: </strong>Female external urinary collection devices were designed with the goal of decreasing the risk of catheter-associated urinary tract infections, which can have significant clinical complications. The BD PureWick urinary collection system, C. R. Bard, Inc., a wholly owned subsidiary of BD, Franklin Lakes, NJ, was the first device to enter the market and has had a widespread distribution. There is a lack of clinical data evaluating the safety of the PureWick device.</p><p><strong>Objectives: </strong>This study aimed to evaluate adverse events associated with the PureWick device using reports from the U.S. Food and Drug Administration Manufacturer and User Device Experience database.</p><p><strong>Study design: </strong>A retrospective case series was conducted of adverse events from the database, which includes the adverse events and patient demographics from mandatory and voluntary reporters. Grounded theory was applied, utilizing inductive reasoning to identify salient keywords in the analysis of adverse events.</p><p><strong>Results: </strong>A total of 1,406 reports were submitted to the database from January 2016 to October 2023, with each report having at least 1 adverse event complaint. Report complaints were classified by patient injury (n = 1412, 67.6%), device malfunction (n = 459, 22.1%), user error (n = 125, 6.0%), device instructions (n = 83, 4.0%) and death (n = 6, 0.29%). Salient keywords include urinary tract infection, skin irritation, and device leakage.</p><p><strong>Conclusions: </strong>There are adverse events associated with the PureWick external urinary collection device in reports from the U.S. Food and Drug Administration database. These findings warrant additional studies to assess the safety of the PureWick for patients using the device in the hospital and at home.</p>","PeriodicalId":75288,"journal":{"name":"Urogynecology (Hagerstown, Md.)","volume":" ","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2025-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Urogynecology (Hagerstown, Md.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/SPV.0000000000001656","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Importance: Female external urinary collection devices were designed with the goal of decreasing the risk of catheter-associated urinary tract infections, which can have significant clinical complications. The BD PureWick urinary collection system, C. R. Bard, Inc., a wholly owned subsidiary of BD, Franklin Lakes, NJ, was the first device to enter the market and has had a widespread distribution. There is a lack of clinical data evaluating the safety of the PureWick device.

Objectives: This study aimed to evaluate adverse events associated with the PureWick device using reports from the U.S. Food and Drug Administration Manufacturer and User Device Experience database.

Study design: A retrospective case series was conducted of adverse events from the database, which includes the adverse events and patient demographics from mandatory and voluntary reporters. Grounded theory was applied, utilizing inductive reasoning to identify salient keywords in the analysis of adverse events.

Results: A total of 1,406 reports were submitted to the database from January 2016 to October 2023, with each report having at least 1 adverse event complaint. Report complaints were classified by patient injury (n = 1412, 67.6%), device malfunction (n = 459, 22.1%), user error (n = 125, 6.0%), device instructions (n = 83, 4.0%) and death (n = 6, 0.29%). Salient keywords include urinary tract infection, skin irritation, and device leakage.

Conclusions: There are adverse events associated with the PureWick external urinary collection device in reports from the U.S. Food and Drug Administration database. These findings warrant additional studies to assess the safety of the PureWick for patients using the device in the hospital and at home.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
2.80
自引率
0.00%
发文量
0
期刊最新文献
Adverse Events Associated With Female External Urinary Collection Devices. Tamsulosin to Prevent Urinary Retention After Vaginal Urogynecologic Surgery. The Effect of Concomitant Hysterectomy Route on Robotic Sacrocolpopexy Outcomes. Urogynecology Research Is Underrepresented in Top Obstetrics and Gynecology Journals. Treatment Crossover Following Advanced Therapy for Overactive Bladder Syndrome.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1