Universal Adhesive Fortified With Inorganic Nanoparticles on Dentin Affected by Caries: A Comprehensive Study Utilizing SEM, EDX, Micro-Tensile Bond Strength and Antimicrobial Effectiveness.

IF 2 3区 工程技术 Q2 ANATOMY & MORPHOLOGY Microscopy Research and Technique Pub Date : 2025-02-21 DOI:10.1002/jemt.24816
Mohammed Hussain Dafer Al Wadei, Syed Zubairuddin Ahmed, Maei Hesham Almoallim, Fatimah Muneer Towaireet, Tameem Hamad, Muhammad Atif Agwan, Fayez Hussain Niazi, Mohammed Noushad
{"title":"Universal Adhesive Fortified With Inorganic Nanoparticles on Dentin Affected by Caries: A Comprehensive Study Utilizing SEM, EDX, Micro-Tensile Bond Strength and Antimicrobial Effectiveness.","authors":"Mohammed Hussain Dafer Al Wadei, Syed Zubairuddin Ahmed, Maei Hesham Almoallim, Fatimah Muneer Towaireet, Tameem Hamad, Muhammad Atif Agwan, Fayez Hussain Niazi, Mohammed Noushad","doi":"10.1002/jemt.24816","DOIUrl":null,"url":null,"abstract":"<p><p>The present lab-based research aimed to assess the impact of different nanofillers: silver (Ag) chitosan (CH), and arginine nanoparticles (ArgNPs) infused in the eighth-generation universal adhesive (UA) on the antimicrobial potency, micro-tensile bond strength (μTBS), and degree of conversion (DC) bonded to carious-affected dentin (CAD) surface. Forty extracted human molars with Class 1 carious lesions were included. CAD was exposed and samples were allocated into four groups based on the type of adhesive (n = 10): Group 1 (UA), Group 2 (1 wt% AgNPs-UA), Group 3 (1 wt% CHNPs-UA), and Group 4 (1 wt% ArgNPs-UA). Survival rate assessment of inoculated Streptococcus mutans was performed after exposing them to different NPs. Characterization of tested nanoparticles (NPs) was also performed using scanning electron microscopy and energy-dispersive X-ray spectroscopy (EDX). The DC of modified and unmodified eighth-generation adhesive cured and uncured was assessed using Fourier transform infrared spectroscopy (FTIR). Composite was bonded on the CAD and samples underwent artificial aging. Beams were prepared for scanning electron microscopy (SEM) and μTBS analysis followed by failure mode assessment using a stereomicroscope. Statistical analysis was conducted using one-way analysis of variance (ANOVA) and Tukey's post hoc test to compare the means and standard deviations (SDs) between the different experimental groups (p < 0.05). Group 2 (1 wt% AgNPs-UA) samples exhibited the lowest S. mutans survival (0.10 ± 0.02 CFU/mL). Whereas Group 1 (UA) displayed the highest survival of tested bacteria (0.41 ± 0.08 CFU/mL). The maximum score of bond strength of composite to the CAD was detected in Group 2 (1 wt% AgNPs-UA) (21.11 ± 0.59 MPa) samples. However, the μTBS was minimal in Group 1 (UA) (16.18 ± 0.91 MPa). DC between the modified adhesive with 1 wt% AgNPs and the unmodified adhesive was comparable (p > 0.05). The incorporation of 1 wt% AgNPs in eighth-generation adhesives represents a favorable and reasonable alternative to unmodified adhesives when used on caries-affected dentin.</p>","PeriodicalId":18684,"journal":{"name":"Microscopy Research and Technique","volume":" ","pages":""},"PeriodicalIF":2.0000,"publicationDate":"2025-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microscopy Research and Technique","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1002/jemt.24816","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANATOMY & MORPHOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The present lab-based research aimed to assess the impact of different nanofillers: silver (Ag) chitosan (CH), and arginine nanoparticles (ArgNPs) infused in the eighth-generation universal adhesive (UA) on the antimicrobial potency, micro-tensile bond strength (μTBS), and degree of conversion (DC) bonded to carious-affected dentin (CAD) surface. Forty extracted human molars with Class 1 carious lesions were included. CAD was exposed and samples were allocated into four groups based on the type of adhesive (n = 10): Group 1 (UA), Group 2 (1 wt% AgNPs-UA), Group 3 (1 wt% CHNPs-UA), and Group 4 (1 wt% ArgNPs-UA). Survival rate assessment of inoculated Streptococcus mutans was performed after exposing them to different NPs. Characterization of tested nanoparticles (NPs) was also performed using scanning electron microscopy and energy-dispersive X-ray spectroscopy (EDX). The DC of modified and unmodified eighth-generation adhesive cured and uncured was assessed using Fourier transform infrared spectroscopy (FTIR). Composite was bonded on the CAD and samples underwent artificial aging. Beams were prepared for scanning electron microscopy (SEM) and μTBS analysis followed by failure mode assessment using a stereomicroscope. Statistical analysis was conducted using one-way analysis of variance (ANOVA) and Tukey's post hoc test to compare the means and standard deviations (SDs) between the different experimental groups (p < 0.05). Group 2 (1 wt% AgNPs-UA) samples exhibited the lowest S. mutans survival (0.10 ± 0.02 CFU/mL). Whereas Group 1 (UA) displayed the highest survival of tested bacteria (0.41 ± 0.08 CFU/mL). The maximum score of bond strength of composite to the CAD was detected in Group 2 (1 wt% AgNPs-UA) (21.11 ± 0.59 MPa) samples. However, the μTBS was minimal in Group 1 (UA) (16.18 ± 0.91 MPa). DC between the modified adhesive with 1 wt% AgNPs and the unmodified adhesive was comparable (p > 0.05). The incorporation of 1 wt% AgNPs in eighth-generation adhesives represents a favorable and reasonable alternative to unmodified adhesives when used on caries-affected dentin.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
Microscopy Research and Technique
Microscopy Research and Technique 医学-解剖学与形态学
CiteScore
5.30
自引率
20.00%
发文量
233
审稿时长
4.7 months
期刊介绍: Microscopy Research and Technique (MRT) publishes articles on all aspects of advanced microscopy original architecture and methodologies with applications in the biological, clinical, chemical, and materials sciences. Original basic and applied research as well as technical papers dealing with the various subsets of microscopy are encouraged. MRT is the right form for those developing new microscopy methods or using the microscope to answer key questions in basic and applied research.
期刊最新文献
"Histological and Immunohistochemical Characterization of the Kidney and Adrenal Gland in Nile Monitor Lizards (Varanus niloticus)". Measuring Colloidal Forces With Atomic Force Microscopy 1: Salt Influence on Hydrophobic and Hydrophilic Interactions. Universal Adhesive Fortified With Inorganic Nanoparticles on Dentin Affected by Caries: A Comprehensive Study Utilizing SEM, EDX, Micro-Tensile Bond Strength and Antimicrobial Effectiveness. Cover Image Issue Information
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1