Norton Sakassegawa Yanagimori, Bernardo Kaplan Moscovici, Gicele Rodrigues Chaves Rinaldo, Priscila Ciocler Froiman, Ivan Corso Teixeira
{"title":"Femtosecond Laser Liquid Optics Interface as Low Vision Optical Resource.","authors":"Norton Sakassegawa Yanagimori, Bernardo Kaplan Moscovici, Gicele Rodrigues Chaves Rinaldo, Priscila Ciocler Froiman, Ivan Corso Teixeira","doi":"10.1080/02713683.2025.2478239","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the efficacy of a low-cost optical magnifier created from the repurposed femtosecond laser interface used in cataract surgery to reduce healthcare waste and financial burden for low-vision patients.</p><p><strong>Methods: </strong>This prospective study included 16 Brazilian patients from the Low Vision Department of the Irmandade da Santa Casa de Misericórdia de São Paulo. Participants had visual acuity between +0.5 and +1.3 logMAR and visual field constrictions under 20°. The Catalys<sup>®</sup> femtosecond laser interface lens, usually discarded after surgery, was sterilized and attached to a recyclable support to create a magnifying device. Patients were trained to use it for 30 days. Visual function was assessed with the NEI VFQ-25, and reading performance was measured using the MNREAD-P test.</p><p><strong>Results: </strong>Thirteen patients (81.25%) completed the study. The use of the optical device led to significant improvements in all MNREAD-P parameters. Reading acuity improved from 0.74 ± 0.19 logMAR (20/110 Snellen) to 0.41 ± 0.22 logMAR (20/50 Snellen) (<i>p</i> < 0.001). Critical print size decreased from 0.85 ± 0.19 logMAR (20/140 Snellen) to 0.56 ± 0.24 logMAR (20/70 Snellen) (<i>p</i> < 0.001). Maximum reading speed increased from 41.4 ± 18.0 words per minute (wpm) to 56.2 ± 25.2 wpm (<i>p</i> < 0.001). NEI VFQ-25 scores improved from 32.7 ± 13.8 to 46.9 ± 15.0 (<i>p</i> < 0.001), with increases observed in all subcategories, particularly in \"Reactions to Vision Problems.\"</p><p><strong>Conclusion: </strong>Repurposing the femtosecond laser interface lens as a low-cost magnifier showed promising improvements in reading and visual function for low-vision patients while addressing healthcare waste. Further studies with larger samples are recommended to validate and expand this sustainable approach in visual rehabilitation.</p>","PeriodicalId":10782,"journal":{"name":"Current Eye Research","volume":" ","pages":"1-6"},"PeriodicalIF":1.7000,"publicationDate":"2025-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Eye Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/02713683.2025.2478239","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: To assess the efficacy of a low-cost optical magnifier created from the repurposed femtosecond laser interface used in cataract surgery to reduce healthcare waste and financial burden for low-vision patients.
Methods: This prospective study included 16 Brazilian patients from the Low Vision Department of the Irmandade da Santa Casa de Misericórdia de São Paulo. Participants had visual acuity between +0.5 and +1.3 logMAR and visual field constrictions under 20°. The Catalys® femtosecond laser interface lens, usually discarded after surgery, was sterilized and attached to a recyclable support to create a magnifying device. Patients were trained to use it for 30 days. Visual function was assessed with the NEI VFQ-25, and reading performance was measured using the MNREAD-P test.
Results: Thirteen patients (81.25%) completed the study. The use of the optical device led to significant improvements in all MNREAD-P parameters. Reading acuity improved from 0.74 ± 0.19 logMAR (20/110 Snellen) to 0.41 ± 0.22 logMAR (20/50 Snellen) (p < 0.001). Critical print size decreased from 0.85 ± 0.19 logMAR (20/140 Snellen) to 0.56 ± 0.24 logMAR (20/70 Snellen) (p < 0.001). Maximum reading speed increased from 41.4 ± 18.0 words per minute (wpm) to 56.2 ± 25.2 wpm (p < 0.001). NEI VFQ-25 scores improved from 32.7 ± 13.8 to 46.9 ± 15.0 (p < 0.001), with increases observed in all subcategories, particularly in "Reactions to Vision Problems."
Conclusion: Repurposing the femtosecond laser interface lens as a low-cost magnifier showed promising improvements in reading and visual function for low-vision patients while addressing healthcare waste. Further studies with larger samples are recommended to validate and expand this sustainable approach in visual rehabilitation.
期刊介绍:
The principal aim of Current Eye Research is to provide rapid publication of full papers, short communications and mini-reviews, all high quality. Current Eye Research publishes articles encompassing all the areas of eye research. Subject areas include the following: clinical research, anatomy, physiology, biophysics, biochemistry, pharmacology, developmental biology, microbiology and immunology.