Effect of Three Heating Guns on the Temperature of Two Bulk-Fill Resin-Based Composites

IF 4.1 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Esthetic and Restorative Dentistry Pub Date : 2025-03-17 DOI:10.1111/jerd.13457
Juliana Anany Gonzales Guarneri, Cristiane Maucoski, Fabrício Mezzomo Collares, Richard Bengt Price, Cesar Augusto Galvão Arrais
{"title":"Effect of Three Heating Guns on the Temperature of Two Bulk-Fill Resin-Based Composites","authors":"Juliana Anany Gonzales Guarneri,&nbsp;Cristiane Maucoski,&nbsp;Fabrício Mezzomo Collares,&nbsp;Richard Bengt Price,&nbsp;Cesar Augusto Galvão Arrais","doi":"10.1111/jerd.13457","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objective</h3>\n \n <p>To evaluate the effect of three heating guns—Phasor (Vista Apex, Racine, USA), VisCalor (VOCO, Cuxhaven, Germany), and Compex HD (AdDent Inc. Danbury, USA)—on the temperature changes of two bulk-fill resin-based composites (RBCs): VisCalor Bulk (VBF, VOCO) and Filtek One Bulk Fill Restorative (OBF, Solventum, St. Paul, USA).</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>Temperature changes were measured using a thermal camera (PI 640i, Optris Infrared Measurements, Berlin, Germany) during insertion and photocuring in a simulated proximal box of a Class II cavity and within the RBC capsules during heating. The RBCs were photocured using the Bluephase PowerCure (Ivoclar, Schaan, Liechtenstein) for 20s. Data were analyzed using repeated measures ANOVA and Tukey's test for each RBC (<i>α</i> = 0.05). The temperature of the RBCs at the same depth were analyzed by <i>t</i>-test (<i>α</i> = 0.05).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>OBF heated with Compex produced the lowest temperature rise at the pulpal floor (2.7°C ± 0.4°C), while VBF heated with Phasor produced the highest (8.8°C ± 2.4°C). The greatest temperature increases were at the top of the restoration. OBF heated with Phasor reached 48.6°C ± 4.7°C. The Phasor and VisCalor produced two temperature peaks in the RBC inside the capsule, while the Compex maintained a steady peak temperature.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>The heating gun and RBC produced different temperatures when heating, inserting, and light-activation of the RBCs.</p>\n </section>\n \n <section>\n \n <h3> Clinical Significance</h3>\n \n <p>The choice of RBC and heating gun can substantially affect the temperature of the RBC and influence its handling properties.</p>\n </section>\n </div>","PeriodicalId":15988,"journal":{"name":"Journal of Esthetic and Restorative Dentistry","volume":"37 7","pages":"1802-1813"},"PeriodicalIF":4.1000,"publicationDate":"2025-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/jerd.13457","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Esthetic and Restorative Dentistry","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jerd.13457","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objective

To evaluate the effect of three heating guns—Phasor (Vista Apex, Racine, USA), VisCalor (VOCO, Cuxhaven, Germany), and Compex HD (AdDent Inc. Danbury, USA)—on the temperature changes of two bulk-fill resin-based composites (RBCs): VisCalor Bulk (VBF, VOCO) and Filtek One Bulk Fill Restorative (OBF, Solventum, St. Paul, USA).

Materials and Methods

Temperature changes were measured using a thermal camera (PI 640i, Optris Infrared Measurements, Berlin, Germany) during insertion and photocuring in a simulated proximal box of a Class II cavity and within the RBC capsules during heating. The RBCs were photocured using the Bluephase PowerCure (Ivoclar, Schaan, Liechtenstein) for 20s. Data were analyzed using repeated measures ANOVA and Tukey's test for each RBC (α = 0.05). The temperature of the RBCs at the same depth were analyzed by t-test (α = 0.05).

Results

OBF heated with Compex produced the lowest temperature rise at the pulpal floor (2.7°C ± 0.4°C), while VBF heated with Phasor produced the highest (8.8°C ± 2.4°C). The greatest temperature increases were at the top of the restoration. OBF heated with Phasor reached 48.6°C ± 4.7°C. The Phasor and VisCalor produced two temperature peaks in the RBC inside the capsule, while the Compex maintained a steady peak temperature.

Conclusion

The heating gun and RBC produced different temperatures when heating, inserting, and light-activation of the RBCs.

Clinical Significance

The choice of RBC and heating gun can substantially affect the temperature of the RBC and influence its handling properties.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
三种加热枪对两种块状填充树脂基复合材料温度的影响
目的:评估三种加热枪的效果:评估三种加热枪--Phasor(Vista Apex,美国 Racine)、VisCalor(VOCO,德国 Cuxhaven)和 Compex HD(AdDent Inc:材料和方法:使用热像仪(PI 640i,Optris Infrared Measurements,德国柏林)测量插入和光固化过程中的温度变化,以及模拟 II 类龋洞近端盒和加热过程中 RBC 囊内的温度变化。使用 Bluephase PowerCure(Ivoclar,Schaan,列支敦士登)对 RBC 进行 20 秒钟的光固化。采用重复测量方差分析和 Tukey 检验对每个 RBC 进行数据分析(α = 0.05)。同一深度的 RBC 温度采用 t 检验进行分析(α = 0.05):结果:使用康培加热的 OBF 在牙髓底层产生的温升最低(2.7°C ± 0.4°C),而使用 Phasor 加热的 VBF 产生的温升最高(8.8°C ± 2.4°C)。修复体顶部的温度上升幅度最大。使用 Phasor 加热的 OBF 达到 48.6°C ± 4.7°C。Phasor和VisCalor在囊内的RBC中产生了两个温度峰值,而Compex则保持了一个稳定的温度峰值:结论:加热枪和 RBC 在加热、插入和光激活 RBC 时产生不同的温度:临床意义:RBC 和加热枪的选择会极大地影响 RBC 的温度,并影响其操作性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Esthetic and Restorative Dentistry
Journal of Esthetic and Restorative Dentistry 医学-牙科与口腔外科
CiteScore
6.30
自引率
6.20%
发文量
124
审稿时长
>12 weeks
期刊介绍: The Journal of Esthetic and Restorative Dentistry (JERD) is the longest standing peer-reviewed journal devoted solely to advancing the knowledge and practice of esthetic dentistry. Its goal is to provide the very latest evidence-based information in the realm of contemporary interdisciplinary esthetic dentistry through high quality clinical papers, sound research reports and educational features. The range of topics covered in the journal includes: - Interdisciplinary esthetic concepts - Implants - Conservative adhesive restorations - Tooth Whitening - Prosthodontic materials and techniques - Dental materials - Orthodontic, periodontal and endodontic esthetics - Esthetics related research - Innovations in esthetics
期刊最新文献
Clinical Performance of Resin-Based Composite and Resin-Modified Glass Ionomer in Restoring Cervical Carious Lesions: A Systematic Review and Meta-Analysis. The Effect of Preheating, Resin-Based Composite, and Wire Types of Orthodontic Lingual Fixed Retainers on the Load at Failure: A Comparative In-Vitro Study. Influence of Finish Line and CAM Unit on the Marginal Adaptation and Margin Trueness of Lithium Disilicate Glass-Ceramic and Composite Resin Onlay Restorations. Aging Restorations in the Esthetic Zone: A Visual and Spectrophotometric Outcome. Effects of Ozonized Oil on At-Home Tooth Bleaching: A Double-Blind Randomized Clinical Trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1