Ruth Rodríguez Montaño, Mario A Alarcón-Sánchez, Melissa Martínez Nieto, Juan J Varela Hernández, Sarah M Lomelí Martínez
{"title":"Application of nanotechnology to dentistry: Impact of graphene nanocomposites on clinical air quality.","authors":"Ruth Rodríguez Montaño, Mario A Alarcón-Sánchez, Melissa Martínez Nieto, Juan J Varela Hernández, Sarah M Lomelí Martínez","doi":"10.12998/wjcc.v13.i8.100839","DOIUrl":null,"url":null,"abstract":"<p><p>Concerns about air quality in dental clinics where aerosol generation during procedures poses significant health risks, have prompted investigations on advanced disinfection technologies. This editorial describes the strengths and limitations of ventilation and aerosol control measures in dental offices, especially with respect to the use of graphene nanocomposites. The potential of graphene nanocomposites as an innovative solution to aerosol-associated health risks is examined in this review due to the unique properties of graphene (<i>e.g.</i>, high conductivity, mechanical strength, and antimicrobial activity). These properties have produced promising results in various fields, but the application of graphene in dentistry remains unexplored. The recent study by Ju <i>et al</i> which was published in <i>World Journal of Clinical Cases</i> evaluated the effectiveness of graphene-based air disinfection systems in dental clinics. The study demonstrated that graphene-based disinfection techniques produced significant reductions in suspended particulate matter and bacterial colony counts, when compared with traditional methods. Despite these positive results, challenges such as material saturation, frequency of filter replacement, and associated costs must be addressed before widespread adoption of graphene-based disinfection techniques in clinical practice. Therefore, there is need for further research on material structure optimization, long-term safety evaluations, and broader clinical applications, in order to maximize their positive impact on public health.</p>","PeriodicalId":23912,"journal":{"name":"World Journal of Clinical Cases","volume":"13 8","pages":"100839"},"PeriodicalIF":1.0000,"publicationDate":"2025-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11670009/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"World Journal of Clinical Cases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.12998/wjcc.v13.i8.100839","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Concerns about air quality in dental clinics where aerosol generation during procedures poses significant health risks, have prompted investigations on advanced disinfection technologies. This editorial describes the strengths and limitations of ventilation and aerosol control measures in dental offices, especially with respect to the use of graphene nanocomposites. The potential of graphene nanocomposites as an innovative solution to aerosol-associated health risks is examined in this review due to the unique properties of graphene (e.g., high conductivity, mechanical strength, and antimicrobial activity). These properties have produced promising results in various fields, but the application of graphene in dentistry remains unexplored. The recent study by Ju et al which was published in World Journal of Clinical Cases evaluated the effectiveness of graphene-based air disinfection systems in dental clinics. The study demonstrated that graphene-based disinfection techniques produced significant reductions in suspended particulate matter and bacterial colony counts, when compared with traditional methods. Despite these positive results, challenges such as material saturation, frequency of filter replacement, and associated costs must be addressed before widespread adoption of graphene-based disinfection techniques in clinical practice. Therefore, there is need for further research on material structure optimization, long-term safety evaluations, and broader clinical applications, in order to maximize their positive impact on public health.
期刊介绍:
The World Journal of Clinical Cases (WJCC) is a high-quality, peer reviewed, open-access journal. The primary task of WJCC is to rapidly publish high-quality original articles, reviews, editorials, and case reports in the field of clinical cases. In order to promote productive academic communication, the peer review process for the WJCC is transparent; to this end, all published manuscripts are accompanied by the anonymized reviewers’ comments as well as the authors’ responses. The primary aims of the WJCC are to improve diagnostic, therapeutic and preventive modalities and the skills of clinicians and to guide clinical practice in clinical cases.