{"title":"Influence of intraocular scattered light on lightness-scaling experiments.","authors":"W A Stiehl, J J McCann, R L Savoy","doi":"10.1364/josa.73.001143","DOIUrl":null,"url":null,"abstract":"<p><p>Following Munsell's bisection procedure [J. Opt. Soc. Am. 23, 394 (1933)], we established a nine-step gray scale in which each step is an equal increment in lightness. We calculated retinal illuminances after intraocular scatter by using the point-spread function of Vos et al. [Vision Res. 16, 215-219 (1976)]. After this correction for intraocular scatter, we find a logarithmic relationship between retinal illuminance and achromatic lightness scales that are determined by the bisection method. Additional bisection experiments with a series of different backgrounds corroborate this result. We find that lightness depends linearly on the logarithm of scatter-corrected retinal illuminance, with different slopes for backgrounds of different lightness. This study also highlights the importance of using scatter-corrected illuminance in any quantitative model of lightness.</p>","PeriodicalId":17413,"journal":{"name":"Journal of the Optical Society of America","volume":"73 9","pages":"1143-8"},"PeriodicalIF":0.0000,"publicationDate":"1983-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1364/josa.73.001143","citationCount":"57","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Optical Society of America","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1364/josa.73.001143","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 57
Abstract
Following Munsell's bisection procedure [J. Opt. Soc. Am. 23, 394 (1933)], we established a nine-step gray scale in which each step is an equal increment in lightness. We calculated retinal illuminances after intraocular scatter by using the point-spread function of Vos et al. [Vision Res. 16, 215-219 (1976)]. After this correction for intraocular scatter, we find a logarithmic relationship between retinal illuminance and achromatic lightness scales that are determined by the bisection method. Additional bisection experiments with a series of different backgrounds corroborate this result. We find that lightness depends linearly on the logarithm of scatter-corrected retinal illuminance, with different slopes for backgrounds of different lightness. This study also highlights the importance of using scatter-corrected illuminance in any quantitative model of lightness.
期刊介绍:
OSA was published by The Optical Society from January 1917 to December 1983 before dividing into JOSA A: Optics and Image Science and JOSA B: Optical Physics in 1984.