{"title":"[Basic study on blood pressure measurements with a digital sphygmomanometers].","authors":"K Shibata, K Namikawa, C Murase","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In the present study, digital sphygmomanometer (SMmeter)(Omuron Digital 709 Fuzzy and Digital 806F)for family use and 24 hour ambulatory SMmeter were checked in terms of reproducibility (CV%) of blood pressure(BP) measured and comparison of measured BP with Digital SMmeter with those measured with mercury SMmeter, the golden standard. Reproducibility of BP measured with Hg-SMmeter was less than 4%, with each Digital SMmeter less than 9%. Inter-unit reproducibility was less than 5% in each SMmeter. Systolic BP measured with 24 hour ambulatory SMmeter were higher by 2-4% than BP measured with Hg-SMmeter, diastolic BP higher by 4-9%. Systolic BP measured with Digital 709 Fuzzy were higher by 5-10% than Hg-SMmeter in lower range of systolic BP to be actually measured, in 130-170 mmHg both values almost coincident, in more than 170 mmHg Digital 709 Fuzzy lower by 2-7%. Diastolic BP measured with Digital 709 Fuzzy were higher by 10-15% than Hg-SMmeter in lower range of diastolic BP to be actually measured. In more than 80 mmHg both values were almost coincident. Systolic BP with Digital 806F were higher by 1.5-7%, diastolic BP higher by about 10% than the value with Hg-SMmeter. In conclusion, by taking account of different reproducibilities and characteristics of SMmeter, home BP monitoring can be performed by patient or/and his family.</p>","PeriodicalId":76067,"journal":{"name":"Kango kenkyu. The Japanese journal of nursing research","volume":"30 4","pages":"69-75"},"PeriodicalIF":0.0000,"publicationDate":"1997-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kango kenkyu. The Japanese journal of nursing research","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In the present study, digital sphygmomanometer (SMmeter)(Omuron Digital 709 Fuzzy and Digital 806F)for family use and 24 hour ambulatory SMmeter were checked in terms of reproducibility (CV%) of blood pressure(BP) measured and comparison of measured BP with Digital SMmeter with those measured with mercury SMmeter, the golden standard. Reproducibility of BP measured with Hg-SMmeter was less than 4%, with each Digital SMmeter less than 9%. Inter-unit reproducibility was less than 5% in each SMmeter. Systolic BP measured with 24 hour ambulatory SMmeter were higher by 2-4% than BP measured with Hg-SMmeter, diastolic BP higher by 4-9%. Systolic BP measured with Digital 709 Fuzzy were higher by 5-10% than Hg-SMmeter in lower range of systolic BP to be actually measured, in 130-170 mmHg both values almost coincident, in more than 170 mmHg Digital 709 Fuzzy lower by 2-7%. Diastolic BP measured with Digital 709 Fuzzy were higher by 10-15% than Hg-SMmeter in lower range of diastolic BP to be actually measured. In more than 80 mmHg both values were almost coincident. Systolic BP with Digital 806F were higher by 1.5-7%, diastolic BP higher by about 10% than the value with Hg-SMmeter. In conclusion, by taking account of different reproducibilities and characteristics of SMmeter, home BP monitoring can be performed by patient or/and his family.