Does the design of self-ligating brackets show different behavior in terms of friction?

Simona Tecco, Giuseppe Marzo, Beatrice Di Bisceglie, Vito Crincoli, Stefano Tetè, Felice Festa
{"title":"Does the design of self-ligating brackets show different behavior in terms of friction?","authors":"Simona Tecco,&nbsp;Giuseppe Marzo,&nbsp;Beatrice Di Bisceglie,&nbsp;Vito Crincoli,&nbsp;Stefano Tetè,&nbsp;Felice Festa","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>This in vitro study evaluated the friction generated by aligned stainless steel conventional brackets, self-ligating Damon MX brackets, Time3 brackets, Vision LP brackets, and low-friction Slide ligatures coupled with various stainless steel, nickel-titanium (Ni-Ti), and beta-titanium (TMA) archwires.</p><p><strong>Methods: </strong>All brackets had a 0.022-inch slot; the orthodontic archwires were 0.014-inch Ni-Ti, 0.016-inch Ni-Ti, 0.014 x 0.025-inch Ni-Ti, 0.018 x 0.025-inch Ni-Ti, 0.017 x 0.025-inch TMA, 0.019 x 0.025-inch stainless steel, and 0.019 x 0.025-inch Ni-Ti. Each bracket-archwire combination was tested 10 times.</p><p><strong>Results: </strong>Coupled with 0.014-inch Ni-Ti and 0.016-inch Ni-Ti archwire, conventional brackets generated the greatest friction, while Damon MX and Vision LP brackets generated the lowest (P < .05). No significant difference was observed between Time3 brackets and Slide ligatures. Coupled with all the rectangular archwires, Victory Series brackets, Slide ligatures, and Vision LP self-ligating brackets generated significantly lower friction than Time3 and Damon MX self-ligating brackets (P < .05).</p><p><strong>Conclusion: </strong>These findings suggest that self-ligating brackets are a great family of brackets that, in vitro, can generate different levels of friction when coupled with thin, thick, rectangular, or round archwires. Clinical conclusions based on our results are not possible, due to the limitations of the experimental conditions.</p>","PeriodicalId":89450,"journal":{"name":"Orthodontics : the art and practice of dentofacial enhancement","volume":"12 4","pages":"330-9"},"PeriodicalIF":0.0000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthodontics : the art and practice of dentofacial enhancement","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: This in vitro study evaluated the friction generated by aligned stainless steel conventional brackets, self-ligating Damon MX brackets, Time3 brackets, Vision LP brackets, and low-friction Slide ligatures coupled with various stainless steel, nickel-titanium (Ni-Ti), and beta-titanium (TMA) archwires.

Methods: All brackets had a 0.022-inch slot; the orthodontic archwires were 0.014-inch Ni-Ti, 0.016-inch Ni-Ti, 0.014 x 0.025-inch Ni-Ti, 0.018 x 0.025-inch Ni-Ti, 0.017 x 0.025-inch TMA, 0.019 x 0.025-inch stainless steel, and 0.019 x 0.025-inch Ni-Ti. Each bracket-archwire combination was tested 10 times.

Results: Coupled with 0.014-inch Ni-Ti and 0.016-inch Ni-Ti archwire, conventional brackets generated the greatest friction, while Damon MX and Vision LP brackets generated the lowest (P < .05). No significant difference was observed between Time3 brackets and Slide ligatures. Coupled with all the rectangular archwires, Victory Series brackets, Slide ligatures, and Vision LP self-ligating brackets generated significantly lower friction than Time3 and Damon MX self-ligating brackets (P < .05).

Conclusion: These findings suggest that self-ligating brackets are a great family of brackets that, in vitro, can generate different levels of friction when coupled with thin, thick, rectangular, or round archwires. Clinical conclusions based on our results are not possible, due to the limitations of the experimental conditions.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
自栓支架的设计在摩擦方面是否表现出不同的行为?
目的:本体外研究评估排列不锈钢常规托槽、自结扎Damon MX托槽、Time3托槽、Vision LP托槽和低摩擦Slide托槽与各种不锈钢、镍钛(Ni-Ti)和β -钛(TMA)弓丝联合产生的摩擦。方法:所有托槽均为0.022英寸;正畸弓丝分别为0.014英寸Ni-Ti、0.016英寸Ni-Ti、0.014 x 0.025英寸Ni-Ti、0.018 x 0.025英寸Ni-Ti、0.017 x 0.025英寸TMA、0.019 x 0.025英寸不锈钢和0.019 x 0.025英寸Ni-Ti。每个支架-弓丝组合测试10次。结果:与0.014英寸Ni-Ti和0.016英寸Ni-Ti弓丝结合使用,常规托槽产生的摩擦最大,Damon MX和Vision LP托槽产生的摩擦最小(P < 0.05)。Time3托槽与Slide结扎无显著差异。与所有矩形弓丝结合使用时,Victory Series托槽、Slide结扎和Vision LP自结扎托槽产生的摩擦明显低于Time3和Damon MX自结扎托槽(P < 0.05)。结论:这些研究结果表明,自结扎托槽是一个伟大的托槽家族,在体外,当与薄、厚、矩形或圆形弓丝结合时,可以产生不同程度的摩擦。由于实验条件的限制,不能根据我们的结果得出临床结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Relationship between crown-root angulation (collum angle) of maxillary central incisors in Class II, division 2 malocclusion and lower lip line. Nickel and chromium levels in the saliva of patients with fixed orthodontic appliances. Shear bond strength of orthodontic brackets bonded to porcelain following etching with Er:YAG laser versus hydrofluoric acid. Individualized orthodontic treatment: The Insignia system. Speedy orthodontics: a case report.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1