A broadband pulse EPR spectrometer for high-throughput measurements in the X-band

Nikolay P. Isaev , Anatoly R. Melnikov , Konstantin A. Lomanovich , Mikhail V. Dugin , Mikhail Yu. Ivanov , Dmitriy N. Polovyanenko , Sergey L. Veber , Michael K. Bowman , Elena G. Bagryanskaya
{"title":"A broadband pulse EPR spectrometer for high-throughput measurements in the X-band","authors":"Nikolay P. Isaev ,&nbsp;Anatoly R. Melnikov ,&nbsp;Konstantin A. Lomanovich ,&nbsp;Mikhail V. Dugin ,&nbsp;Mikhail Yu. Ivanov ,&nbsp;Dmitriy N. Polovyanenko ,&nbsp;Sergey L. Veber ,&nbsp;Michael K. Bowman ,&nbsp;Elena G. Bagryanskaya","doi":"10.1016/j.jmro.2022.100092","DOIUrl":null,"url":null,"abstract":"<div><p>We present an X-band pulse EPR spectrometer with high throughput and excellent sensitivity in the 8.5-11.5GHz range. It is designed for high stability and low noise Fourier Transform measurements for applications in pulse dipolar spectroscopy, pulse hyperfine spectroscopy, and spin relaxation from cryogenic temperatures to room temperature. An arbitrary waveform generator is used to generate pulses of any frequency and shape for multiple resonance experiments or for uniform broadband excitation with bandwidths exceeding 350 MHz. We illustrate the capabilities and performance of the spectrometer by measurements on free radicals and biradicals in solids and liquids. Relaxation times of radicals in liquid solution are measured for fewer than 30,000,000 spins (less than 3 nanomoles per liter). Non-uniform acquisition provides higher throughput for mixtures of radicals with quite different relaxation rates. Conventional DEER measurements on a rigid biradical have good modulation depth. Broadband SIFTER with chirped adiabatic WURST pulses demonstrates versatility for the latest broadband pulse schemes. A broadband ESEEM measurement correlates ESEEM and EPR frequencies which characterize the conformation of a nitroxide radical. The entire EPR spectrum with a width approaching 300 MHz was excited and detected throughout the measurement. The spectrometer supports the operator in tuning, setting up experiments and monitoring their progress so that even novice users consistently can obtain optimal results.</p></div>","PeriodicalId":365,"journal":{"name":"Journal of Magnetic Resonance Open","volume":"14 ","pages":"Article 100092"},"PeriodicalIF":2.6240,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Magnetic Resonance Open","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666441022000620","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

We present an X-band pulse EPR spectrometer with high throughput and excellent sensitivity in the 8.5-11.5GHz range. It is designed for high stability and low noise Fourier Transform measurements for applications in pulse dipolar spectroscopy, pulse hyperfine spectroscopy, and spin relaxation from cryogenic temperatures to room temperature. An arbitrary waveform generator is used to generate pulses of any frequency and shape for multiple resonance experiments or for uniform broadband excitation with bandwidths exceeding 350 MHz. We illustrate the capabilities and performance of the spectrometer by measurements on free radicals and biradicals in solids and liquids. Relaxation times of radicals in liquid solution are measured for fewer than 30,000,000 spins (less than 3 nanomoles per liter). Non-uniform acquisition provides higher throughput for mixtures of radicals with quite different relaxation rates. Conventional DEER measurements on a rigid biradical have good modulation depth. Broadband SIFTER with chirped adiabatic WURST pulses demonstrates versatility for the latest broadband pulse schemes. A broadband ESEEM measurement correlates ESEEM and EPR frequencies which characterize the conformation of a nitroxide radical. The entire EPR spectrum with a width approaching 300 MHz was excited and detected throughout the measurement. The spectrometer supports the operator in tuning, setting up experiments and monitoring their progress so that even novice users consistently can obtain optimal results.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于x波段高通量测量的宽带脉冲EPR光谱仪
在8.5-11.5GHz范围内,我们设计了一种高通量、高灵敏度的x波段脉冲EPR光谱仪。它是专为高稳定性和低噪声傅立叶变换测量应用于脉冲偶极光谱,脉冲超精细光谱,自旋弛豫从低温到室温。任意波形发生器用于产生任意频率和形状的脉冲,用于多次共振实验或带宽超过350 MHz的均匀宽带激励。我们通过测量固体和液体中的自由基和双自由基来说明光谱仪的能力和性能。自由基在液体溶液中的弛豫时间被测量小于3000万自旋(小于3纳摩尔每升)。非均匀获取为具有不同弛豫速率的自由基混合物提供了更高的通量。在刚性双基上的传统DEER测量具有良好的调制深度。具有啁啾绝热WURST脉冲的宽带SIFTER展示了最新宽带脉冲方案的多功能性。宽带ESEEM测量将表征氮氧化物自由基构象的ESEEM和EPR频率联系起来。整个EPR频谱宽度接近300 MHz,在整个测量过程中被激发和检测。该光谱仪支持操作员调整,设置实验和监测其进展,以便即使是新手用户也能始终如一地获得最佳结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
1.90
自引率
0.00%
发文量
0
期刊最新文献
Improved 2D hydride detection for NMR-chemosensing via p‐H2 Hyperpolarization A practical guide to metal ions dynamic nuclear polarization in materials science Current state of the art of analyte scope in urine metabolome analysis by non-hydrogenative PHIP Natural abundance 195Pt-13C correlation NMR spectroscopy on surfaces enabled by fast MAS dynamic nuclear polarization Nuclear hyperpolarization in electron-transfer proteins: Revealing unexpected light-induced 15N signals with field-cycling magic-angle spinning NMR
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1