Blood Flow Assessment of Arteriovenous Malformations Using Intraoperative Indocyanine Green Videoangiography.

IF 1.8 Q3 PERIPHERAL VASCULAR DISEASE Stroke Research and Treatment Pub Date : 2019-03-17 eCollection Date: 2019-01-01 DOI:10.1155/2019/7292304
Naoki Kato, Vincent Prinz, Julius Dengler, Peter Vajkoczy
{"title":"Blood Flow Assessment of Arteriovenous Malformations Using Intraoperative Indocyanine Green Videoangiography.","authors":"Naoki Kato,&nbsp;Vincent Prinz,&nbsp;Julius Dengler,&nbsp;Peter Vajkoczy","doi":"10.1155/2019/7292304","DOIUrl":null,"url":null,"abstract":"<p><p>Intraoperative indocyanine green (ICG) videoangiography is widely used in patients undergoing neurosurgery. FLOW800 is a recently developed analytical tool for ICG videoangiography to assess semi-quantitative flow dynamics; however, its efficacy is unknown. In this study, we evaluated its functionality in the assessment of flow dynamics of arteriovenous malformation (AVM) through ICG videoangiography under clinical settings. ICG videoangiography was performed in the exposed AVM in eight patients undergoing surgery. FLOW800 analysis was applied directly, and gray-scale and color-coded maps of the surgical field were obtained. After surgery, a region of interest was placed on the individual vessels to obtain time-intensity curves. Parameters of flow dynamics, including the maximum intensity, transit time, and cerebral blood flow index, were calculated using the curves. The color-coded maps provided high-resolution images; however, reconstruction of colored images was restricted by the depth, approach angle, and brain swelling. Semi-quantitative parameters were similar among the feeders, niduses, and drainers. However, a higher cerebral blood flow index was observed in the feeders of large AVM (>3 cm) than in those of small AVM (P < 0.05). Similarly, the cerebral blood flow index values were positively correlated with the nidus volume (P < 0.01). FLOW800 enabled visualization of the AVM structure and safer resection, except in case of deep-seated AVM. Moreover, semi-quantitative values in the individual vessels through using ICG intensity diagram showed different patterns according to size of the AVM. ICG videoangiography showed good performance in evaluating flow dynamics of the AVM in patients undergoing surgery.</p>","PeriodicalId":22054,"journal":{"name":"Stroke Research and Treatment","volume":"2019 ","pages":"7292304"},"PeriodicalIF":1.8000,"publicationDate":"2019-03-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2019/7292304","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Stroke Research and Treatment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2019/7292304","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 13

Abstract

Intraoperative indocyanine green (ICG) videoangiography is widely used in patients undergoing neurosurgery. FLOW800 is a recently developed analytical tool for ICG videoangiography to assess semi-quantitative flow dynamics; however, its efficacy is unknown. In this study, we evaluated its functionality in the assessment of flow dynamics of arteriovenous malformation (AVM) through ICG videoangiography under clinical settings. ICG videoangiography was performed in the exposed AVM in eight patients undergoing surgery. FLOW800 analysis was applied directly, and gray-scale and color-coded maps of the surgical field were obtained. After surgery, a region of interest was placed on the individual vessels to obtain time-intensity curves. Parameters of flow dynamics, including the maximum intensity, transit time, and cerebral blood flow index, were calculated using the curves. The color-coded maps provided high-resolution images; however, reconstruction of colored images was restricted by the depth, approach angle, and brain swelling. Semi-quantitative parameters were similar among the feeders, niduses, and drainers. However, a higher cerebral blood flow index was observed in the feeders of large AVM (>3 cm) than in those of small AVM (P < 0.05). Similarly, the cerebral blood flow index values were positively correlated with the nidus volume (P < 0.01). FLOW800 enabled visualization of the AVM structure and safer resection, except in case of deep-seated AVM. Moreover, semi-quantitative values in the individual vessels through using ICG intensity diagram showed different patterns according to size of the AVM. ICG videoangiography showed good performance in evaluating flow dynamics of the AVM in patients undergoing surgery.

Abstract Image

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
术中吲哚菁绿血管造影评价动静脉畸形的血流。
术中吲哚菁绿(ICG)血管造影广泛应用于神经外科患者。FLOW800是最近开发的ICG视频血管造影分析工具,用于评估半定量血流动力学;然而,其功效尚不清楚。在这项研究中,我们评估了其在临床环境下通过ICG血管造影评估动静脉畸形(AVM)血流动力学的功能。对8例手术患者的外露AVM行ICG血管造影。直接应用FLOW800分析,获得手术野的灰度图和彩色编码图。手术后,在单个血管上放置感兴趣的区域以获得时间-强度曲线。利用曲线计算血流动力学参数,包括最大血流强度、穿越时间和脑血流指数。彩色编码的地图提供了高分辨率图像;然而,彩色图像的重建受到深度、入路角度和脑肿胀的限制。喂食器、病灶和引流器的半定量参数相似。大AVM (>3 cm)的脑血流量指数高于小AVM (P < 0.05)。脑血流指数值与病灶体积呈正相关(P < 0.01)。FLOW800实现了AVM结构的可视化和更安全的切除,但深层AVM除外。此外,根据AVM的大小,ICG强度图在单个血管中的半定量值呈现不同的模式。ICG血管造影在评估手术患者AVM血流动力学方面表现良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Stroke Research and Treatment
Stroke Research and Treatment PERIPHERAL VASCULAR DISEASE-
CiteScore
3.20
自引率
0.00%
发文量
14
审稿时长
12 weeks
期刊最新文献
Does Action Observation of the Whole Task Influence Mirror Neuron System and Upper Limb Muscle Activity Better Than Part Task in People With Stroke? Evaluation of Contralateral Limb Cross Education and High-Frequency Repetitive Transcranial Magnetic Stimulation on Functional Indices of the Affected Upper Limb in Subacute Phase of Stroke External Validation of SAFE Score to Predict Atrial Fibrillation Diagnosis after Ischemic Stroke: A Retrospective Multicenter Study Modeling Survival Time to Death among Stroke Patients at Jimma University Medical Center, Southwest Ethiopia: A Retrospective Cohort Study. Effect of Self-Directed Home Therapy Adherence Combined with TheraBracelet on Poststroke Hand Recovery: A Pilot Study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1