Nasima Mehraban, Alexandra R Lew, Ian M Foran, Simon Lee, Daniel D Bohl, Kamran S Hamid
{"title":"Lateral Locking Plate Fixation of Simple Weber B Fibula Fractures Without a Lag Screw Yields Excellent Radiographic Results.","authors":"Nasima Mehraban, Alexandra R Lew, Ian M Foran, Simon Lee, Daniel D Bohl, Kamran S Hamid","doi":"10.1177/19386400211055280","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The most common first-line fixation technique for simple Weber B fibula fractures is a lag screw with lateral neutralization plate. The most common surgical technique for unstable Weber B fibula fracture is one-third semi-tubular plate and cortical screws, implemented with lag screw when appropriate. However, the lag technique can be technically challenging in osteoporotic bone or within fibulas of smaller diameter, and in some cases can result in fragmentation at the fracture site, malreduction, or peroneal irritation. The purpose of this study is to examine an alternative first-line method for routine treatment of simple Weber B fibula fractures.</p><p><strong>Methods: </strong>Fifty-two consecutive patients undergoing open reduction internal fixation (ORIF) of a Weber B fibula fracture by a single surgeon were included in this retrospective study. After reduction, a lateral locking plate was applied with cortical screws proximally and locking screws distally. No screw crossed the fracture in any case. Per published precedent, nonunion was defined as either a gap of >3 mm between fracture surfaces >6 months postoperatively or a fracture line >2 to 3 mm wide and sclerosing of the fracture surfaces. Similarly, malunion was defined as one or more of the following: talar tilt >2º, talar subluxation >2 mm, or tibiofibular clear space ≥5 mm.</p><p><strong>Results: </strong>The mean (± standard deviation) age of the 52 included patients was 44.2 ± 16.2 years, the mean body mass index was 27.7 ± 6.6 kg/m<sup>2</sup>, and 63.5% of patients identified themselves as female sex. The mean follow-up was 6.2 (range: 1.5-15) months. In addition to undergoing fixation of the lateral malleolus, 21 patients also underwent fixation of the posterior malleolus, 27 underwent fixation of the medial malleolus, 29 underwent fixation across the syndesmosis, and 7 underwent repair of the deltoid. In all patients, bony anatomic union of the fibula and congruence of the mortise were achieved with no cases of malunion or nonunion.</p><p><strong>Conclusions: </strong>The Arbeitsgemeinschaft für Osteosynthesefragen (AO) fixation technique for simple Weber B fractures with a lag screw and lateral neutralization plating has provided good outcomes for decades. We present an alternative technique for ORIF of these fractures with a lateral locking plate and no lag screw. In our series, we evaluated radiographic union and alignment as our primary outcome measures and found no cases of nonunion or malunion. Prospective cohort testing of lateral locking plates versus traditional fixation in the context of patient-centered value is warranted.<b>Level of Evidence:</b> Level III.</p>","PeriodicalId":73046,"journal":{"name":"Foot & ankle specialist","volume":" ","pages":"131-136"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Foot & ankle specialist","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/19386400211055280","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/11/7 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The most common first-line fixation technique for simple Weber B fibula fractures is a lag screw with lateral neutralization plate. The most common surgical technique for unstable Weber B fibula fracture is one-third semi-tubular plate and cortical screws, implemented with lag screw when appropriate. However, the lag technique can be technically challenging in osteoporotic bone or within fibulas of smaller diameter, and in some cases can result in fragmentation at the fracture site, malreduction, or peroneal irritation. The purpose of this study is to examine an alternative first-line method for routine treatment of simple Weber B fibula fractures.
Methods: Fifty-two consecutive patients undergoing open reduction internal fixation (ORIF) of a Weber B fibula fracture by a single surgeon were included in this retrospective study. After reduction, a lateral locking plate was applied with cortical screws proximally and locking screws distally. No screw crossed the fracture in any case. Per published precedent, nonunion was defined as either a gap of >3 mm between fracture surfaces >6 months postoperatively or a fracture line >2 to 3 mm wide and sclerosing of the fracture surfaces. Similarly, malunion was defined as one or more of the following: talar tilt >2º, talar subluxation >2 mm, or tibiofibular clear space ≥5 mm.
Results: The mean (± standard deviation) age of the 52 included patients was 44.2 ± 16.2 years, the mean body mass index was 27.7 ± 6.6 kg/m2, and 63.5% of patients identified themselves as female sex. The mean follow-up was 6.2 (range: 1.5-15) months. In addition to undergoing fixation of the lateral malleolus, 21 patients also underwent fixation of the posterior malleolus, 27 underwent fixation of the medial malleolus, 29 underwent fixation across the syndesmosis, and 7 underwent repair of the deltoid. In all patients, bony anatomic union of the fibula and congruence of the mortise were achieved with no cases of malunion or nonunion.
Conclusions: The Arbeitsgemeinschaft für Osteosynthesefragen (AO) fixation technique for simple Weber B fractures with a lag screw and lateral neutralization plating has provided good outcomes for decades. We present an alternative technique for ORIF of these fractures with a lateral locking plate and no lag screw. In our series, we evaluated radiographic union and alignment as our primary outcome measures and found no cases of nonunion or malunion. Prospective cohort testing of lateral locking plates versus traditional fixation in the context of patient-centered value is warranted.Level of Evidence: Level III.