{"title":"Medium-long-term outcomes of saphenous vein graft in Peyronie surgery: Is there a need for new graft material?","authors":"Yavuz Güler","doi":"10.1016/j.androl.2020.12.009","DOIUrl":null,"url":null,"abstract":"<div><h3>Aim</h3><p>We present our results of tunical incision and saphenous graft surgery for men with short penis and who cannot have sexual relations due to curvature linked to chronic Peyronie plaques.</p></div><div><h3>Introduction</h3><p>Peyronie disease is a chronic process where fibrotic plaques form in the tunica albuginea. The plaques cause pain in the acute period and cause the penis to bend after inflammation ends. Surgical procedures are required for curvature<!--> <!-->><!--> <!-->30°. Saphenous vein graft (SVG) replacement is an alternative method for tunical plaque incision defect.</p></div><div><h3>Material-method</h3><p>The outcomes for 71 patients with TI+SVG surgery were retrospectively assessed. Plaque features (curvature angle, location, direction of curve and tunical defect diameter), operative and postoperative properties (surgery duration, recurrent curvature, penis shortening, glans hypoesthesia, satisfaction score, follow-up duration), preoperative–postoperative penis length and IIEF-5 score differences were assessed.</p></div><div><h3>Results</h3><p>Mean age was 61.12<!--> <!-->±<!--> <!-->7.9 (45–75) years, mean curvature angle was 62.0<!--> <!-->±<!--> <!-->14.7 (50–90), location was mid-penile for 46 (65%), with angulation direction toward the dorsal for 37 (52%), and the defect area after tunical incision was 15.5<!--> <!-->±<!--> <!-->3.9 (10–23) cm<sup>2</sup>. With mean follow-up duration of 37<!--> <!-->±<!--> <!-->9.4 months, 9 patients had re-curvature (13.2%), 8 had short penis (11.3%) and 7 had ED identified (9.4%). Total penis straightening was present for 86.8%, with patient satisfaction score of 21.1<!--> <!-->±<!--> <!-->4.4 (8–25).</p></div><div><h3>Conclusion</h3><p>The TI<!--> <!-->+<!--> <span>SVG method is an effective method for Peyronie surgery in the medium-long term.</span></p></div>","PeriodicalId":49129,"journal":{"name":"Revista Internacional De Andrologia","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Internacional De Andrologia","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1698031X22000218","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ANDROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Aim
We present our results of tunical incision and saphenous graft surgery for men with short penis and who cannot have sexual relations due to curvature linked to chronic Peyronie plaques.
Introduction
Peyronie disease is a chronic process where fibrotic plaques form in the tunica albuginea. The plaques cause pain in the acute period and cause the penis to bend after inflammation ends. Surgical procedures are required for curvature > 30°. Saphenous vein graft (SVG) replacement is an alternative method for tunical plaque incision defect.
Material-method
The outcomes for 71 patients with TI+SVG surgery were retrospectively assessed. Plaque features (curvature angle, location, direction of curve and tunical defect diameter), operative and postoperative properties (surgery duration, recurrent curvature, penis shortening, glans hypoesthesia, satisfaction score, follow-up duration), preoperative–postoperative penis length and IIEF-5 score differences were assessed.
Results
Mean age was 61.12 ± 7.9 (45–75) years, mean curvature angle was 62.0 ± 14.7 (50–90), location was mid-penile for 46 (65%), with angulation direction toward the dorsal for 37 (52%), and the defect area after tunical incision was 15.5 ± 3.9 (10–23) cm2. With mean follow-up duration of 37 ± 9.4 months, 9 patients had re-curvature (13.2%), 8 had short penis (11.3%) and 7 had ED identified (9.4%). Total penis straightening was present for 86.8%, with patient satisfaction score of 21.1 ± 4.4 (8–25).
Conclusion
The TI + SVG method is an effective method for Peyronie surgery in the medium-long term.
期刊介绍:
Revista Internacional de Andrología es la revista oficial de la Asociación Española de Andrología, Medicina Sexual y Reproductiva (ASESA), la Sociedade Portuguesa de Ardrologia, la Sociedad Argentina de Andrología (SAA), la Asociación Iberoamericana de Sociedades de Andrología (ANDRO), y la Federación Española de Sociedades de Sexología.
La revista publicada trimestralmente es revisada por pares y es líder en el la especialidad y en español y portugués. Recientemente también publica artículos en inglés.
El objetivo de la revista es principalmente la promoción del conocimiento y la educación médica continua, con un enfoque especial en el público español y latinoamericano, a través de la publicación de las contribuciones importantes de la investigación en el campo. Todos los miembros de las sociedades antes mencionadas reciben la revista y otros suscriptores individuales e institucionales de España, Portugal y América Latina.