Ferrofluid-Based Preconcentration And Ultra-Trace Determination Of Pt, Pd, Au, And Ag In Complex Matrices Using Inductively Coupled Plasma Mass Spectrometry

IF 3.4 2区 化学 Q1 SPECTROSCOPY Atomic Spectroscopy Pub Date : 2022-11-01 DOI:10.46770/as.2022.229
D. Beauchemin
{"title":"Ferrofluid-Based Preconcentration And Ultra-Trace Determination Of Pt, Pd, Au, And Ag In Complex Matrices Using Inductively Coupled Plasma Mass Spectrometry","authors":"D. Beauchemin","doi":"10.46770/as.2022.229","DOIUrl":null,"url":null,"abstract":": This study presents a method for the ultra-trace determination of several noble metals (Pd, Pt, Au, and Ag) in geological samples through selective preconcentration using a ferrofluid. Specifically, Fe 3 O 4 magnetic nanoparticles (MNPs) coated with silica and titania and functionalized with 3-mercaptopropyltrimethoxysilane and N-(2-aminoethyl)-3-aminopropyltrimethoxysilane were employed for the selective sorption of analytes. After injecting the ferrofluid into an aqueous sample, the functionalized MNPs adsorbed the target analytes within 5 min. The analyte-carrying MNPs were then separated using an external magnet, followed by elution using 10% v/v aqua regia + 3% thiourea. The eluate was analyzed using inductively coupled plasma mass spectrometry. The effects of sample solution pH, eluent composition, elution time, and elution volume on the preconcentration factor were investigated. Under optimized conditions, the detection limits were improved by factors of 8 to 15 for Pt, Pd, Au, and Ag, compared to those obtained without preconcentration. The accuracy of this method was verified by analyzing a certified reference material (CDN-PGMS-29) of ore containing noble metals, and the measured concentrations were consistent with the certified values based on a Student’s t-test at the 95% confidence level.","PeriodicalId":8642,"journal":{"name":"Atomic Spectroscopy","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atomic Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.46770/as.2022.229","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 0

Abstract

: This study presents a method for the ultra-trace determination of several noble metals (Pd, Pt, Au, and Ag) in geological samples through selective preconcentration using a ferrofluid. Specifically, Fe 3 O 4 magnetic nanoparticles (MNPs) coated with silica and titania and functionalized with 3-mercaptopropyltrimethoxysilane and N-(2-aminoethyl)-3-aminopropyltrimethoxysilane were employed for the selective sorption of analytes. After injecting the ferrofluid into an aqueous sample, the functionalized MNPs adsorbed the target analytes within 5 min. The analyte-carrying MNPs were then separated using an external magnet, followed by elution using 10% v/v aqua regia + 3% thiourea. The eluate was analyzed using inductively coupled plasma mass spectrometry. The effects of sample solution pH, eluent composition, elution time, and elution volume on the preconcentration factor were investigated. Under optimized conditions, the detection limits were improved by factors of 8 to 15 for Pt, Pd, Au, and Ag, compared to those obtained without preconcentration. The accuracy of this method was verified by analyzing a certified reference material (CDN-PGMS-29) of ore containing noble metals, and the measured concentrations were consistent with the certified values based on a Student’s t-test at the 95% confidence level.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于铁磁流体的预富集和使用电感耦合等离子体质谱法在复杂基质中超痕量测定Pt, Pd, Au和Ag
:本研究提出了一种使用铁磁流体通过选择性预富集超痕量测定地质样品中几种贵金属(Pd、Pt、Au和Ag)的方法。具体而言,用二氧化硅和二氧化钛涂覆并用3-巯基丙基三甲氧基硅烷和N-(2-氨基乙基)-3-氨基丙基三甲氧基硅烷官能化的Fe3O4磁性纳米颗粒(MNPs)用于分析物的选择性吸附。将铁磁流体注入水性样品后,功能化的MNP在5分钟内吸附目标分析物。然后使用外部磁体分离携带分析物的MNP,然后使用10%v/v王水+3%硫脲洗脱。使用电感耦合等离子体质谱法对洗脱液进行分析。考察了样品溶液pH、洗脱液组成、洗脱时间和洗脱体积对预富集因子的影响。在优化的条件下,与未预富集的情况相比,Pt、Pd、Au和Ag的检测限提高了8-15倍。通过分析含贵金属矿石的认证参考物质(CDN-PGMS-29)验证了该方法的准确性,并且在95%置信水平下,测量的浓度与基于Student t检验的认证值一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Atomic Spectroscopy
Atomic Spectroscopy 物理-光谱学
CiteScore
5.30
自引率
14.70%
发文量
42
审稿时长
4.5 months
期刊介绍: The ATOMIC SPECTROSCOPY is a peer-reviewed international journal started in 1962 by Dr. Walter Slavin and now is published by Atomic Spectroscopy Press Limited (ASPL). It is intended for the rapid publication of both original articles and review articles in the fields of AAS, AFS, ICP-OES, ICP-MS, GD-MS, TIMS, SIMS, AMS, LIBS, XRF and related techniques. Manuscripts dealing with (i) instrumentation & fundamentals, (ii) methodology development & applications, and (iii) standard reference materials (SRMs) development can be submitted for publication.
期刊最新文献
Determination of REEs in Seawater RMs (NASS-7, CASS-6, and NMIJ 7204-A) Using Online Automated Separation ICP-MS Analysis System A Glimpse Into The Nature Of Particles Created During Pulsed Laser Ablation Of Arsenic Compounds In Ambient Gases Determination Of Sb Isotope Ratios In Stibnite Using Fs-LA-MC-ICP-MS And Two Potential Reference Materials Study Atom Probe Tomography Reveals Nano-Scale Organic Remaining In Conodont A Spectral Optimization Method To Enhance Handheld LIBS For T91 Aging Grade Classification Using Lorentzian Profile And Kalman Filter
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1