The Roughening Effects of Er:YAG, Nd:YAG and KTP Laser Systems on Root Dentin Surface

Q3 Dentistry Cumhuriyet Dental Journal Pub Date : 2023-03-26 DOI:10.7126/cumudj.1242258
R. Zan, H. Topçuoğlu, İ. Hubbezoğlu, D. Altunbaş, Arzu Şeyma Demi̇r
{"title":"The Roughening Effects of Er:YAG, Nd:YAG and KTP Laser Systems on Root Dentin Surface","authors":"R. Zan, H. Topçuoğlu, İ. Hubbezoğlu, D. Altunbaş, Arzu Şeyma Demi̇r","doi":"10.7126/cumudj.1242258","DOIUrl":null,"url":null,"abstract":"Objectives: Present study aimed to evaluate the roughening ability of different laser systems on the middle and apical third of roots. \nMaterials and Methods: Sixty extracted human single-rooted single canal mandibular premolar teeth were randomly assigned to 3 groups (n=20). Standardized preparation and sterilization procedures were performed. The samples were irradiated with Er:YAG, Nd:YAG, and KTP laser systems. The laser irradiations (1.5 Watt) were applied with a spiral motion, starting 1 mm short of the apex and then moving coronally for 10 sec, interleaved with 15-sec recovery intervals for each irradiation. This process was repeated twelve times. The roots that were standardized in the same length and thicknesses were divided parallel to the longitudinal axis. Then, the middle and apical 1/3 surface roughness values of each root section were measured using a profilometer and SEM analysis was performed. The data obtained were analyzed using the two-way analysis of variance (ANOVA) and Tukey post-hoc tests. \nResults: According to measurements obtained from middle and apical 1/3 surfaces; Although, the statistically highest roughness value was determined after Nd:YAG laser (P < 0.05), the statistically lowest value was detected following the Er:YAG laser irradiation (P < 0.05). \nConclusions: In light of the present study, all laser systems caused significant roughness surface. Therefore, laser systems should be carefully applied in human root canals.","PeriodicalId":10781,"journal":{"name":"Cumhuriyet Dental Journal","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cumhuriyet Dental Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7126/cumudj.1242258","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Present study aimed to evaluate the roughening ability of different laser systems on the middle and apical third of roots. Materials and Methods: Sixty extracted human single-rooted single canal mandibular premolar teeth were randomly assigned to 3 groups (n=20). Standardized preparation and sterilization procedures were performed. The samples were irradiated with Er:YAG, Nd:YAG, and KTP laser systems. The laser irradiations (1.5 Watt) were applied with a spiral motion, starting 1 mm short of the apex and then moving coronally for 10 sec, interleaved with 15-sec recovery intervals for each irradiation. This process was repeated twelve times. The roots that were standardized in the same length and thicknesses were divided parallel to the longitudinal axis. Then, the middle and apical 1/3 surface roughness values of each root section were measured using a profilometer and SEM analysis was performed. The data obtained were analyzed using the two-way analysis of variance (ANOVA) and Tukey post-hoc tests. Results: According to measurements obtained from middle and apical 1/3 surfaces; Although, the statistically highest roughness value was determined after Nd:YAG laser (P < 0.05), the statistically lowest value was detected following the Er:YAG laser irradiation (P < 0.05). Conclusions: In light of the present study, all laser systems caused significant roughness surface. Therefore, laser systems should be carefully applied in human root canals.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Er:YAG、Nd:YAG和KTP激光系统对牙根表面粗糙化的影响
目的:评价不同激光系统对根中、根尖三分之一的粗化能力。材料与方法:选择拔除的人单根单管下颌前磨牙60颗,随机分为3组(n=20)。执行标准化的制备和灭菌程序。用Er:YAG、Nd:YAG和KTP激光系统辐照样品。激光照射(1.5瓦)以螺旋运动施加,从离顶点1毫米处开始,然后冠状移动10秒,每次照射间隔15秒。这个过程重复了12次。在相同长度和厚度的标准化根被划分平行于纵轴。然后,用轮廓仪测量每个根切片的中部和根尖1/3的表面粗糙度值,并进行扫描电镜分析。采用双向方差分析(ANOVA)和Tukey事后检验对所得数据进行分析。结果:根据中间和根尖1/3面的测量结果;Nd:YAG激光照射后粗糙度值最高(P < 0.05), Er:YAG激光照射后粗糙度值最低(P < 0.05)。结论:根据目前的研究,所有的激光系统都造成了明显的表面粗糙度。因此,激光系统应用于根管治疗时应谨慎。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Cumhuriyet Dental Journal
Cumhuriyet Dental Journal Dentistry-Dentistry (all)
CiteScore
0.40
自引率
0.00%
发文量
0
审稿时长
8 weeks
期刊最新文献
The Effects of Home and Over-The-Counter Whitening Agents on Surface Roughness and Microhardness of High Aesthetic Composites Çocukların Ağız Alışkanlıklarına İlişkin Ebeveyn Farkındalık ve Bilgi Düzeyinin Değerlendirilmesi: Bir Anket Çalışması İmplant destekli sabit bölümlü protez tedavisi yapılan hastalarında yaşam kalitesi ve memnuniyetinin değerlendirilmesi Comparison of Clinical and Radiographic Healing of Periapical Lesions Using MTA or Conventional Filling Materials: Randomized Controlled Clinical Trial Effect of Music Therapy on Dental Anxiety in Periodontal Surgery
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1