Supercapacitor based PV measurement technique − quality assessment with poly-Si PV modules at IIEST, Kolkata

S. Basu Pal, Rahul Kumar, K. Das Bhattacharya, D. Mukherjee, D. Paul
{"title":"Supercapacitor based PV measurement technique − quality assessment with poly-Si PV modules at IIEST, Kolkata","authors":"S. Basu Pal, Rahul Kumar, K. Das Bhattacharya, D. Mukherjee, D. Paul","doi":"10.1051/ijmqe/2019007","DOIUrl":null,"url":null,"abstract":"Supercapacitors have been used for the first time as load to PV cell/modules for characterizing their behavior. In this paper, a novel and essentially simple design of a V–I plotter is attempted with a bank of super capacitors (SC) as the load to the PV modules of varying capacities. The distinct advantages of the SC's over the erstwhile capacitors have been comparatively experimented. Finally, an elaborate regression analysis (RA) of principal electrical parameters have yielded consistently high values exceeding 0.993 experimental evaluation of quality parameters like fill-factor (FF) and performance ratio (PR) have yielded a range of 70–79% while PR values frequently ranges from 90% to 99%. Suitability of poly-Si PV modules at the level of PV panel configurations have been ascertained through experimental estimate of series and parallel relative power loss (RPL) values. Typical values below 2% obtained for widely varying climatic level is also a quality indicator for the new metrology in question. Such a prototype I–V plotter is expected to be duly considered for commercial testing applications in PV industries.","PeriodicalId":38371,"journal":{"name":"International Journal of Metrology and Quality Engineering","volume":"8 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1051/ijmqe/2019007","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Metrology and Quality Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/ijmqe/2019007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 1

Abstract

Supercapacitors have been used for the first time as load to PV cell/modules for characterizing their behavior. In this paper, a novel and essentially simple design of a V–I plotter is attempted with a bank of super capacitors (SC) as the load to the PV modules of varying capacities. The distinct advantages of the SC's over the erstwhile capacitors have been comparatively experimented. Finally, an elaborate regression analysis (RA) of principal electrical parameters have yielded consistently high values exceeding 0.993 experimental evaluation of quality parameters like fill-factor (FF) and performance ratio (PR) have yielded a range of 70–79% while PR values frequently ranges from 90% to 99%. Suitability of poly-Si PV modules at the level of PV panel configurations have been ascertained through experimental estimate of series and parallel relative power loss (RPL) values. Typical values below 2% obtained for widely varying climatic level is also a quality indicator for the new metrology in question. Such a prototype I–V plotter is expected to be duly considered for commercial testing applications in PV industries.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于超级电容器的光伏测量技术-加尔各答iest多晶硅光伏模块的质量评估
超级电容器首次被用作光伏电池/组件的负载,以表征其性能。在本文中,尝试了一种新颖且本质上简单的V-I绘图仪设计,使用一组超级电容器(SC)作为不同容量光伏模块的负载。相对于以往的电容器,SC具有明显的优势。最后,对主要电气参数进行详细的回归分析(RA),得出的值一直很高,超过0.993。对填充系数(FF)和性能比(PR)等质量参数的实验评价得出的值在70-79%之间,而PR的值通常在90% - 99%之间。通过对串联和并联相对功率损耗(RPL)值的实验估计,确定了多晶硅光伏组件在光伏面板配置水平上的适用性。在广泛变化的气候水平下获得的低于2%的典型值也是所讨论的新计量学的质量指标。这种原型I-V绘图仪预计将被适当地考虑用于光伏工业的商业测试应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
International Journal of Metrology and Quality Engineering
International Journal of Metrology and Quality Engineering Engineering-Safety, Risk, Reliability and Quality
CiteScore
1.70
自引率
0.00%
发文量
8
审稿时长
8 weeks
期刊最新文献
Investigation of influence of grinding wheel and cutting parameters on surface roughness and surface hardening when relieving grinding the gear milling teeth surface based on the Archimedes' spiral Analysis and treatment of current unbalance abnormal situation of 750 kV double-circuit parallel transmission line Characterizing a linear pyrometer at the National Metrology Institute of South Africa Estimation of parallelism measurement uncertainty according to the Geometrical Product Specifications standard using coordinate measuring machine First study on harvesting electromagnetic noise energy generated by the frequency converters
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1