{"title":"Can Partially Threaded Cannulated Screws Be Better Designed to Maximize Purchase in the Sacrum?","authors":"Shawn E. Boomsma, Ishaq Ibrahim, N. Suneja, A. V. von Keudell, M. Weaver","doi":"10.1615/jlongtermeffmedimplants.2021039485","DOIUrl":null,"url":null,"abstract":"Sacroiliac screw fixation involves the use of cannulated, partially or fully threaded screws. Current partially threaded screws have standardized thread lengths involving a small portion of the screw regardless of its overall length. Forty uninjured computed tomography images were evaluated for distances from the lateral iliac cortex to the lateral sacral cortex at the first and second sacral segments. No difference in measurements were observed for gender, age, or body mass index. Using a smooth segment value of 32 mm, a significant increase in thread lengths is achievable allowing for a novel sacroiliac screw design to achieve greater purchase in the sacrum.","PeriodicalId":16125,"journal":{"name":"Journal of long-term effects of medical implants","volume":"32 2 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of long-term effects of medical implants","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1615/jlongtermeffmedimplants.2021039485","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
Abstract
Sacroiliac screw fixation involves the use of cannulated, partially or fully threaded screws. Current partially threaded screws have standardized thread lengths involving a small portion of the screw regardless of its overall length. Forty uninjured computed tomography images were evaluated for distances from the lateral iliac cortex to the lateral sacral cortex at the first and second sacral segments. No difference in measurements were observed for gender, age, or body mass index. Using a smooth segment value of 32 mm, a significant increase in thread lengths is achievable allowing for a novel sacroiliac screw design to achieve greater purchase in the sacrum.
期刊介绍:
MEDICAL IMPLANTS are being used in every organ of the human body. Ideally, medical implants must have biomechanical properties comparable to those of autogenous tissues without any adverse effects. In each anatomic site, studies of the long-term effects of medical implants must be undertaken to determine accurately the safety and performance of the implants. Today, implant surgery has become an interdisciplinary undertaking involving a number of skilled and gifted specialists. For example, successful cochlear implants will involve audiologists, audiological physicians, speech and language therapists, otolaryngologists, nurses, neuro-otologists, teachers of the deaf, hearing therapists, cochlear implant manufacturers, and others involved with hearing-impaired and deaf individuals.