Misfit of implant prostheses and its impact on clinical outcomes. Definition, assessment and a systematic review of the literature.

J. Katsoulis, T. Takeichi, Ana Sol Gaviria, L. Peter, K. Katsoulis
{"title":"Misfit of implant prostheses and its impact on clinical outcomes. Definition, assessment and a systematic review of the literature.","authors":"J. Katsoulis, T. Takeichi, Ana Sol Gaviria, L. Peter, K. Katsoulis","doi":"10.7892/BORIS.110976","DOIUrl":null,"url":null,"abstract":"BACKGROUND AND AIM Compromised fit between the contact surfaces of screw-retained implant-supported fixed dentures (IFDs) is thought to create uncontrolled strains in the prosthetic components and peri-implant tissues, thus evoking biological and technical complications such as bone loss, screw loosening, component fractures and, at worst, loss of implants or prostheses. The aim of this systematic review was to evaluate the impact of marginal misfit on the clinical outcomes of IFDs, and to elucidate definition and assessment methods for passive fit. MATERIALS AND METHODS A systematic review of the literature was conducted with a PICO question: \"For partially or complete edentulous subjects with screw-retained IFDs, does the marginal misfit at the implant-prosthesis interfaces have an impact on the clinical outcomes?\". A literature search was performed electronically in PubMed (MEDLINE) with the help of Boolean operators to combine key words, and by hand search in relevant journals. English written in vivo studies published before August 31, 2016 that reported on both clinical outcome and related implant prosthesis misfit (gap, strains, torque) were selected using predetermined inclusion criteria. RESULTS The initial search yielded 2626 records. After screening and a subsequent filtering process, five human and five animal studies were included in the descriptive analysis. The selected studies used different methods to assess misfit (linear distortion, vertical gap, strains, screw torque). While two human studies evaluated the biological response and technical complications prospectively over 6 and 12 months, the animal studies had an observation period < 12 weeks. Four human studies analysed retrospectively the 3 to 32 years' outcomes. Screw-related complications were observed, but biological sequelae could not be confirmed. Although the animal studies had different designs, bone adaptation and implant displacement was found in histological analyses. Due to the small number of studies and the heterogenic designs and misfit assessment methods, no meta-analysis of the data could be performed. CONCLUSIONS The current literature provides insufficient evidence as to the effect of misfit at the prosthesis-implant interface on clinical outcomes of screw-retained implant-supported fixed dentures. Marginal gaps and static strains due to screw tightening were not found to have negative effects on initial osseointegration or peri-implant bone stability over time. Based on two clinical studies, the risk for technical screw-related complications was slightly higher. While the degree of tolerable misfit remains a matter of debate, the present data do not imply that clinicians neglect good fit, but aim to achieve the least misfit possible. Conflict of interest statement: The authors declare no conflict of interest. The review was conducted as part of the 2016 Foundation of Oral Rehabilitation Consensus Conference on \"Prosthetic Protocols in Implant-based Oral Rehabilitation\".","PeriodicalId":49259,"journal":{"name":"European Journal of Oral Implantology","volume":"10 Suppl 1 1","pages":"121-138"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"95","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Oral Implantology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7892/BORIS.110976","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 95

Abstract

BACKGROUND AND AIM Compromised fit between the contact surfaces of screw-retained implant-supported fixed dentures (IFDs) is thought to create uncontrolled strains in the prosthetic components and peri-implant tissues, thus evoking biological and technical complications such as bone loss, screw loosening, component fractures and, at worst, loss of implants or prostheses. The aim of this systematic review was to evaluate the impact of marginal misfit on the clinical outcomes of IFDs, and to elucidate definition and assessment methods for passive fit. MATERIALS AND METHODS A systematic review of the literature was conducted with a PICO question: "For partially or complete edentulous subjects with screw-retained IFDs, does the marginal misfit at the implant-prosthesis interfaces have an impact on the clinical outcomes?". A literature search was performed electronically in PubMed (MEDLINE) with the help of Boolean operators to combine key words, and by hand search in relevant journals. English written in vivo studies published before August 31, 2016 that reported on both clinical outcome and related implant prosthesis misfit (gap, strains, torque) were selected using predetermined inclusion criteria. RESULTS The initial search yielded 2626 records. After screening and a subsequent filtering process, five human and five animal studies were included in the descriptive analysis. The selected studies used different methods to assess misfit (linear distortion, vertical gap, strains, screw torque). While two human studies evaluated the biological response and technical complications prospectively over 6 and 12 months, the animal studies had an observation period < 12 weeks. Four human studies analysed retrospectively the 3 to 32 years' outcomes. Screw-related complications were observed, but biological sequelae could not be confirmed. Although the animal studies had different designs, bone adaptation and implant displacement was found in histological analyses. Due to the small number of studies and the heterogenic designs and misfit assessment methods, no meta-analysis of the data could be performed. CONCLUSIONS The current literature provides insufficient evidence as to the effect of misfit at the prosthesis-implant interface on clinical outcomes of screw-retained implant-supported fixed dentures. Marginal gaps and static strains due to screw tightening were not found to have negative effects on initial osseointegration or peri-implant bone stability over time. Based on two clinical studies, the risk for technical screw-related complications was slightly higher. While the degree of tolerable misfit remains a matter of debate, the present data do not imply that clinicians neglect good fit, but aim to achieve the least misfit possible. Conflict of interest statement: The authors declare no conflict of interest. The review was conducted as part of the 2016 Foundation of Oral Rehabilitation Consensus Conference on "Prosthetic Protocols in Implant-based Oral Rehabilitation".
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
种植体假体错位及其对临床结果的影响。定义,评估和文献的系统回顾。
螺钉保留种植支撑固定义齿(IFDs)接触面之间的不配合被认为会在假体部件和种植体周围组织中产生不受控制的应变,从而引起生物和技术并发症,如骨丢失,螺钉松动,部件骨折,最坏的情况下,种植体或假体丢失。本系统综述的目的是评估边缘不匹配对ifd临床结果的影响,并阐明被动匹配的定义和评估方法。材料和方法对文献进行了系统的回顾,并提出了一个PICO问题:“对于部分或完全无牙的受试者,螺钉保留ifd,种植体-假体界面的边缘不匹配是否会影响临床结果?”在PubMed (MEDLINE)中进行电子文献检索,利用布尔运算符组合关键词,手工检索相关期刊。在2016年8月31日前发表的报告临床结果和相关种植体假体不匹配(间隙、应变、扭矩)的英文体内研究,按照预定的纳入标准进行选择。结果初始搜索得到2626条记录。在筛选和随后的筛选过程之后,描述性分析包括五项人类和五项动物研究。所选的研究使用不同的方法来评估失配(线性畸变、垂直间隙、应变、螺钉扭矩)。两项人体研究评估了6个月和12个月的生物学反应和技术并发症,而动物研究的观察期< 12周。四项人类研究回顾性分析了3至32年的结果。观察到螺钉相关并发症,但生物学后遗症无法证实。虽然动物实验有不同的设计,但在组织学分析中发现骨适应和种植体位移。由于研究数量少,且采用异质设计和失配评估方法,因此无法对数据进行meta分析。结论目前文献对假体-种植界面失配对螺钉固位种植固定义齿临床效果的影响证据不足。随着时间的推移,由于螺钉拧紧而产生的边缘间隙和静态应变未发现对初始骨整合或种植体周围骨稳定性有负面影响。根据两项临床研究,技术螺钉相关并发症的风险略高。虽然可容忍的不匹配程度仍然是一个有争议的问题,但目前的数据并不意味着临床医生忽视了良好的匹配,而是旨在实现尽可能少的不匹配。利益冲突声明:作者声明无利益冲突。该综述是2016年口腔康复基金会共识会议“基于种植体的口腔康复修复方案”的一部分。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
European Journal of Oral Implantology
European Journal of Oral Implantology DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.35
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊最新文献
Immediate loading of fixed prostheses in fully edentulous jaws - 1-year follow-up from a single-cohort retrospective study. Research in focus. Dental implants with internal versus external connections: 1-year post-loading results from a pragmatic multicenter randomised controlled trial. Research in focus. Immediate, early (6 weeks) and delayed loading (3 months) of single, partial and full fixed implant supported prostheses: 1-year post-loading data from a multicentre randomised controlled trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1