{"title":"Fast on-line selenium determination in enriched yeast slurry by microwave digestion–hydride generation–atomic absorption spectroscopy","authors":"M.L Mena, M.M Gómez, M.A Palacios, C Cámara","doi":"10.1016/S1381-141X(99)00018-0","DOIUrl":null,"url":null,"abstract":"<div><p><span>The analytical performance of an on-line focused microwave digestion<span> method for the determination of selenium in enriched yeast by hydride generation–atomic absorption spectrometry (HG–AAS) is evaluated. The method is based on the direct injection of slurried samples into a carrier stream of water. Microwave-assisted digestion in the presence of 1% K</span></span><sub>2</sub>S<sub>2</sub>O<sub>8</sub> permits the quantitative extraction of selenium species from the solid samples and their transformation with HCl acid to selenite. Based on a sample injection volume of 100 μl, limits of detection (L.D.) of about 1 ng Se and relative standard deviation (R.S.D.) of 4.5% were obtained. The results of comparison with traditional digestion procedures are reported.</p></div>","PeriodicalId":100862,"journal":{"name":"Laboratory Automation & Information Management","volume":"34 2","pages":"Pages 159-165"},"PeriodicalIF":0.0000,"publicationDate":"1999-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S1381-141X(99)00018-0","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Automation & Information Management","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1381141X99000180","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6
Abstract
The analytical performance of an on-line focused microwave digestion method for the determination of selenium in enriched yeast by hydride generation–atomic absorption spectrometry (HG–AAS) is evaluated. The method is based on the direct injection of slurried samples into a carrier stream of water. Microwave-assisted digestion in the presence of 1% K2S2O8 permits the quantitative extraction of selenium species from the solid samples and their transformation with HCl acid to selenite. Based on a sample injection volume of 100 μl, limits of detection (L.D.) of about 1 ng Se and relative standard deviation (R.S.D.) of 4.5% were obtained. The results of comparison with traditional digestion procedures are reported.
评价了在线聚焦微波消解法测定富集酵母中硒的氢化物发生-原子吸收光谱法(HG–AAS)的分析性能。该方法基于将浆料样品直接注入载水流中。在1%K2S2O8存在下的微波辅助消化允许从固体样品中定量提取硒物种,并用HCl酸将其转化为亚硒酸盐。基于100μl的进样体积,获得了约1 ng Se的检测限(l.D.)和4.5%的相对标准偏差(R.S.D.)。报告了与传统消化程序的比较结果。