{"title":"Study on the sealing test method of hydraulic solenoid valve in nuclear power station","authors":"Haibao Wang, Xudong Tan, Qunxiong Xiao, Xincai Chang","doi":"10.1051/matecconf/202338201001","DOIUrl":null,"url":null,"abstract":"In order to improve the reliability of tripping solenoid valve and switching solenoid valve of steam turbine valve in nuclear power plant and reduce abnormal valve closing. According to the working principle of valves in nuclear power plant, this paper designs a kind of electromagnetic valve sealing test system, including test base, measurement and control system and hydraulic system. The detection system is an offline system. By simulating the real load condition of the steam turbine system, the tightness of the tripping solenoid valve and the switching solenoid valve is tested to improve the reliability of the solenoid valve. The actual application results show that the system operates stably and reliably, is simple to operate, has high detection efficiency and accuracy, and has good use effect.","PeriodicalId":18309,"journal":{"name":"MATEC Web of Conferences","volume":"36 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"MATEC Web of Conferences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/matecconf/202338201001","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In order to improve the reliability of tripping solenoid valve and switching solenoid valve of steam turbine valve in nuclear power plant and reduce abnormal valve closing. According to the working principle of valves in nuclear power plant, this paper designs a kind of electromagnetic valve sealing test system, including test base, measurement and control system and hydraulic system. The detection system is an offline system. By simulating the real load condition of the steam turbine system, the tightness of the tripping solenoid valve and the switching solenoid valve is tested to improve the reliability of the solenoid valve. The actual application results show that the system operates stably and reliably, is simple to operate, has high detection efficiency and accuracy, and has good use effect.
期刊介绍:
MATEC Web of Conferences is an Open Access publication series dedicated to archiving conference proceedings dealing with all fundamental and applied research aspects related to Materials science, Engineering and Chemistry. All engineering disciplines are covered by the aims and scope of the journal: civil, naval, mechanical, chemical, and electrical engineering as well as nanotechnology and metrology. The journal concerns also all materials in regard to their physical-chemical characterization, implementation, resistance in their environment… Other subdisciples of chemistry, such as analytical chemistry, petrochemistry, organic chemistry…, and even pharmacology, are also welcome. MATEC Web of Conferences offers a wide range of services from the organization of the submission of conference proceedings to the worldwide dissemination of the conference papers. It provides an efficient archiving solution, ensuring maximum exposure and wide indexing of scientific conference proceedings. Proceedings are published under the scientific responsibility of the conference editors.