Design of a V-Plate-Wire Mandibular Fixation System

M. Trabia, K. G. Zobotkin, Robert C. Wang
{"title":"Design of a V-Plate-Wire Mandibular Fixation System","authors":"M. Trabia, K. G. Zobotkin, Robert C. Wang","doi":"10.1115/imece2001/bed-23078","DOIUrl":null,"url":null,"abstract":"\n This paper presents a novel method for internal fixation of unstable mandibular fractures. The fixation method uses a three-screw V-shaped plate and a wire. Two screws are placed normal to the fracture line. The plate is first attached to one of the screws. A wire is then passed around the plate and the opposite screw and tightened to bring the two sides of the fracture together and align them. The plate is then fixed to the other side of the fracture using two additional screws. The fixation system is designed such that the plate carries most of the load. Finite element modeling of the system shows that the method is reliable, producing low stresses. The proposed method presents a simple and quick alternative to the usual plates currently used for mandibular fixation.","PeriodicalId":7238,"journal":{"name":"Advances in Bioengineering","volume":"67 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2001-11-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Bioengineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/imece2001/bed-23078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

This paper presents a novel method for internal fixation of unstable mandibular fractures. The fixation method uses a three-screw V-shaped plate and a wire. Two screws are placed normal to the fracture line. The plate is first attached to one of the screws. A wire is then passed around the plate and the opposite screw and tightened to bring the two sides of the fracture together and align them. The plate is then fixed to the other side of the fracture using two additional screws. The fixation system is designed such that the plate carries most of the load. Finite element modeling of the system shows that the method is reliable, producing low stresses. The proposed method presents a simple and quick alternative to the usual plates currently used for mandibular fixation.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
v型钢板-金属丝下颌固定系统的设计
本文提出一种治疗不稳定下颌骨骨折的新方法。固定方法采用三螺钉v型板和一根钢丝。两颗螺钉垂直于骨折线放置。该板首先连接到其中一个螺钉上。然后用一根金属丝绕着钢板和相反的螺钉拧紧,使骨折的两侧连在一起并对齐。然后用另外两颗螺钉将钢板固定在骨折的另一侧。固定系统的设计使板承受大部分的载荷。系统的有限元建模表明,该方法可靠,产生的应力小。所提出的方法提供了一种简单而快速的替代目前用于下颌固定的常用钢板。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effect of Graft Material on Anterior Cruciate Ligament Reconstruction: A 3D Computational Simulation A “Point Cloud” Approach in Superelastic Stent Design Biomechanical Properties of Grown Cartilage Are Decreased in the Presence of Retinoic Acid, Chondroitinase ABC and Ibuprofen Building Cellular Microenvironments to Control Capillary Endothelial Cell Proliferation, Death, and Differentiation Mechanical Factors Can Influence the Gender Differences in the Incidence of Non-Contact Injuries
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1