Reference X-ray Irradiation System for Personal Dosimeter Testing and Calibration of Radiation Detector

IF 0.9 Q4 NUCLEAR SCIENCE & TECHNOLOGY Journal of Radiation Protection and Research Pub Date : 2019-06-30 DOI:10.14407/JRPR.2019.44.2.72
Seung-Kyu Lee, I. Chang, Sang In Kim, Jungil Lee, Hyoungtaek Kim, Jang-Lyul Kim, Min Chae Kim
{"title":"Reference X-ray Irradiation System for Personal Dosimeter Testing and Calibration of Radiation Detector","authors":"Seung-Kyu Lee, I. Chang, Sang In Kim, Jungil Lee, Hyoungtaek Kim, Jang-Lyul Kim, Min Chae Kim","doi":"10.14407/JRPR.2019.44.2.72","DOIUrl":null,"url":null,"abstract":"Materials and Methods: The existing X-ray generator, Phillips MG325, was replaced with YXLON Y.TU 320-D03 in order to generate reference X-ray fields. Theoretical calculations and Monte Carlo simulations were used to determine initial filter thickness. Beam alignment was performed in three steps to deliver a homogeneous radiation dosage to the target at different distances. Finally, the half-value layers were measured for different X-ray fields to verify beam qualities by using an ion chamber.","PeriodicalId":36088,"journal":{"name":"Journal of Radiation Protection and Research","volume":"27 1","pages":""},"PeriodicalIF":0.9000,"publicationDate":"2019-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiation Protection and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14407/JRPR.2019.44.2.72","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 1

Abstract

Materials and Methods: The existing X-ray generator, Phillips MG325, was replaced with YXLON Y.TU 320-D03 in order to generate reference X-ray fields. Theoretical calculations and Monte Carlo simulations were used to determine initial filter thickness. Beam alignment was performed in three steps to deliver a homogeneous radiation dosage to the target at different distances. Finally, the half-value layers were measured for different X-ray fields to verify beam qualities by using an ion chamber.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于个人剂量计测试和辐射探测器校准的参考x射线辐照系统
材料和方法:为了产生参考x射线场,将现有的x射线发生器philips MG325替换为YXLON Y.TU 320-D03。通过理论计算和蒙特卡罗模拟确定了滤波器的初始厚度。光束对准分三个步骤进行,以在不同距离上向目标提供均匀的辐射剂量。最后,利用离子室测量了不同x射线场下的半值层,验证了光束质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Journal of Radiation Protection and Research
Journal of Radiation Protection and Research Physics and Astronomy-Radiation
CiteScore
1.00
自引率
0.00%
发文量
6
期刊最新文献
A Review of Organ Dose Calculation Methods and Tools for Patients Undergoing Diagnostic Nuclear Medicine Procedures SUMRAY: R and Python Codes for Calculating Cancer Risk Due to Radiation Exposure of a Population Assessment of Temporary Radioactivation for Tissue Expanders in Breast Radiation Therapy: Preliminary Study Assessment of Radiological Hazards in Some Foods Products Consumed by the Malian Population Using Gamma Spectrometry Public Exposure to Natural Radiation and the Associated Increased Risk of Lung Cancer in the Betare-Oya Gold Mining Areas, Eastern Cameroon
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1