W. Yoo, D. Cho, K. Jang, S. Shin, J. Seo, Soon-Cheol Chung, G. Tack, Bongsoo Lee, B. Park, J. Moon, Sin Kim
{"title":"Infrared fiber-optic sensor for non-contact temperature measurements","authors":"W. Yoo, D. Cho, K. Jang, S. Shin, J. Seo, Soon-Cheol Chung, G. Tack, Bongsoo Lee, B. Park, J. Moon, Sin Kim","doi":"10.1109/ICSENST.2008.4757156","DOIUrl":null,"url":null,"abstract":"In this study, we have developed a non-contact temperature sensor using a silver halide optical fiber for medical endoscopic usage. We have measured an infrared radiation which is transferred by a silver halide optical fiber from a heat source using a thermal optical power-meter and a thermopile sensor. To increase the amount of infrared radiation through the silver halide optical fiber and to the infrared sensors, optical devices such as an infrared collimator and a focusing lens are used. The relationships between the temperatures of a heat source and the measured output signals are determined. The measurable temperature range of a fiber-optic temperature sensor is from 30 to 60degC. It is expected that a non-contact temperature sensor using an infrared optical fiber can be developed for medical and industrial usages based on the results of this study.","PeriodicalId":6299,"journal":{"name":"2008 3rd International Conference on Sensing Technology","volume":"10 1","pages":"500-503"},"PeriodicalIF":0.0000,"publicationDate":"2008-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 3rd International Conference on Sensing Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2008.4757156","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
In this study, we have developed a non-contact temperature sensor using a silver halide optical fiber for medical endoscopic usage. We have measured an infrared radiation which is transferred by a silver halide optical fiber from a heat source using a thermal optical power-meter and a thermopile sensor. To increase the amount of infrared radiation through the silver halide optical fiber and to the infrared sensors, optical devices such as an infrared collimator and a focusing lens are used. The relationships between the temperatures of a heat source and the measured output signals are determined. The measurable temperature range of a fiber-optic temperature sensor is from 30 to 60degC. It is expected that a non-contact temperature sensor using an infrared optical fiber can be developed for medical and industrial usages based on the results of this study.