Validasi Metode Penetapan Kadar Logam Kadmium (Cd) dalam Sampel Tanah Menggunakan Spektrofotometer Serapan Atom (SSA)-Nyala

Tita Rosita, Dewi Arfina Prasetyo Ningrum, Yulisma Yanti, Zaekhan
{"title":"Validasi Metode Penetapan Kadar Logam Kadmium (Cd) dalam Sampel Tanah Menggunakan Spektrofotometer Serapan Atom (SSA)-Nyala","authors":"Tita Rosita, Dewi Arfina Prasetyo Ningrum, Yulisma Yanti, Zaekhan","doi":"10.22487/kovalen.2022.v8.i3.16028","DOIUrl":null,"url":null,"abstract":"Soil has an important role in life on earth because it supports plant life by providing nutrients and water as well as supporting roots. One of the chemical elements that cause pollution is cadmium. The standard method for analyzing the content of cadmium metal in the soil is using a Flame Atomic Absorption Spectrophotometer (AAS) referring to SNI 8910:2021. This method changes the weight content from one gram to five grams of sample to obtain cadmium metal levels that can be detected by the instrument. Therefore, this method needs to be validated before being used for routine analysis in the laboratory. The validation parameters are linearity, precision, accuracy, method detection limit, and robustness. The Validation results were obtained for the linearity parameter correlation coefficient value of r = 0.999, %RSD repeatability precision parameter of 1.51%, and the intermediate precision was obtained by %RSD analyst 1 : 1.51% and analyst 2 : 0.82%, accuracy parameter obtained the %recovery results were (88.73-97.01)%, the LDM parameter was obtained at 2.03 mg/kg, the robustness parameter was obtained by F-count of 1.25 and F-table of 3.40 which shows the average assay of metals Cd weighing 1, 3, 5, and 8 grams that were not significantly different. Overall, the results of the validation show that the method of assaying cadmium metal using Flame-AAS complies with the acceptance requirements, therefore it can be used for routine analysis in the laboratory.","PeriodicalId":17905,"journal":{"name":"KOVALEN: Jurnal Riset Kimia","volume":"15 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"KOVALEN: Jurnal Riset Kimia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22487/kovalen.2022.v8.i3.16028","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Soil has an important role in life on earth because it supports plant life by providing nutrients and water as well as supporting roots. One of the chemical elements that cause pollution is cadmium. The standard method for analyzing the content of cadmium metal in the soil is using a Flame Atomic Absorption Spectrophotometer (AAS) referring to SNI 8910:2021. This method changes the weight content from one gram to five grams of sample to obtain cadmium metal levels that can be detected by the instrument. Therefore, this method needs to be validated before being used for routine analysis in the laboratory. The validation parameters are linearity, precision, accuracy, method detection limit, and robustness. The Validation results were obtained for the linearity parameter correlation coefficient value of r = 0.999, %RSD repeatability precision parameter of 1.51%, and the intermediate precision was obtained by %RSD analyst 1 : 1.51% and analyst 2 : 0.82%, accuracy parameter obtained the %recovery results were (88.73-97.01)%, the LDM parameter was obtained at 2.03 mg/kg, the robustness parameter was obtained by F-count of 1.25 and F-table of 3.40 which shows the average assay of metals Cd weighing 1, 3, 5, and 8 grams that were not significantly different. Overall, the results of the validation show that the method of assaying cadmium metal using Flame-AAS complies with the acceptance requirements, therefore it can be used for routine analysis in the laboratory.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
使用原子吸收光谱仪(SSA - work),验证土壤样品中镉(Cd)金属水平的方法
土壤在地球上的生命中起着重要的作用,因为它通过提供营养和水以及支持根来支持植物的生命。造成污染的化学元素之一是镉。分析土壤中镉金属含量的标准方法是使用火焰原子吸收分光光度计(AAS),参考SNI 8910:2021。该方法将样品的重量含量从1克改变为5克,以获得仪器可以检测到的镉金属水平。因此,该方法在用于实验室常规分析前需要进行验证。验证参数为线性度、精密度、准确度、方法检出限和鲁棒性。验证结果为线性参数相关系数r = 0.999, %RSD重复性精密度参数为1.51%,分析剂1:1.51%,分析剂2:准确度参数为0.82%,回收率为(88.73 ~ 97.01)%,LDM参数为2.03 mg/kg,稳健性参数为F-count = 1.25, F-table = 3.40,结果表明1、3、5、8 g金属Cd的平均含量差异不显著。综上所述,验证结果表明火焰原子吸收法测定金属镉的方法符合验收要求,可用于实验室的常规分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Molecular Docking Senyawa Aktif Ekstrak Daun Melinjo (Gnetum gnemon) dalam Penghambatan Enzim Histidin Dekarboksilase Uji Cemaran Logam Mangan (Mn), Tembaga (Cu), dan Mikroba pada Air Minum dalam Kemasan Selektivitas Adsorpsi Campuran Biner Fe(II)/Cu(II) Menggunakan Karbon Aktif dari Sekam Padi dan Serbuk Gergaji Kayu Jati Reduksi Kandungan Zat Aktif Anionik dalam Limbah Laundry dengan Memanfaatkan Kombinasi Zeolit dari Tongkol Jagung dan Pseudomonas aeruginosa Kinerja Analitik Mikrokapsul Magnetit - Alginat (MNPs-ALG) untuk Analisis Ion Logam Cu(II) dan Aplikasinya pada Sampel Alam
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1