{"title":"RADIOGRAPHIC ASSESSMENT OF EXTREMITY OSSEOINTEGRATION FOR THE AMPUTEE.","authors":"M. Al Muderis, Belinda A Bosley, A. Florschutz, P. Lunseth, Tyler D. Klenow, M. J. Highsmith, Jason T. Kahle","doi":"10.21300/18.2-3.2016.211","DOIUrl":null,"url":null,"abstract":"Osseointegration (OI) is a bone-anchoring procedure that allows the direct skeletal attachment of a prosthesis through the use of an implant. Transcutaneous OI implants are similar to subcutaneous intramedullary joint implants with some exceptions. Particularly, OI implants are inserted at the distal aspect of the femur, while intramedullary implants are inserted at the proximal aspect of the femur. In this report, an additional adaptation of the radiographic zonal analysis used for intramedullary implants, known as Gruen zones, is introduced to include OI implants of extremity prosthetics. Radiographic zonal analyses and interpretations are proposed. Gruen zones are used for intramedullary implants, which are generally inserted from the proximal aspect of the bone. OI extremity implants are inserted from the distal end of the bone. Therefore, the zonal analysis is inverted. A radiographic zonal analysis has been introduced by the Osseointegration Group of Australia (OGA). This analysis is needed specifically for the clinical evaluation of extremity OI, as significant changes to the bone and OI implant have been reported and need to be clinically described. A classification technique is necessary for establishing treatment guidelines for the extremity osseointegrated implant. The OGA Zonal analysis addresses this need by adapting a common reference standard to osseointegration of the extremity amputee.","PeriodicalId":44009,"journal":{"name":"Technology and Innovation","volume":"31 1","pages":"211-216"},"PeriodicalIF":0.7000,"publicationDate":"2016-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technology and Innovation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21300/18.2-3.2016.211","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 7

Abstract

Osseointegration (OI) is a bone-anchoring procedure that allows the direct skeletal attachment of a prosthesis through the use of an implant. Transcutaneous OI implants are similar to subcutaneous intramedullary joint implants with some exceptions. Particularly, OI implants are inserted at the distal aspect of the femur, while intramedullary implants are inserted at the proximal aspect of the femur. In this report, an additional adaptation of the radiographic zonal analysis used for intramedullary implants, known as Gruen zones, is introduced to include OI implants of extremity prosthetics. Radiographic zonal analyses and interpretations are proposed. Gruen zones are used for intramedullary implants, which are generally inserted from the proximal aspect of the bone. OI extremity implants are inserted from the distal end of the bone. Therefore, the zonal analysis is inverted. A radiographic zonal analysis has been introduced by the Osseointegration Group of Australia (OGA). This analysis is needed specifically for the clinical evaluation of extremity OI, as significant changes to the bone and OI implant have been reported and need to be clinically described. A classification technique is necessary for establishing treatment guidelines for the extremity osseointegrated implant. The OGA Zonal analysis addresses this need by adapting a common reference standard to osseointegration of the extremity amputee.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
截肢者四肢骨整合的影像学评估。
骨整合(OI)是一种骨锚定程序,允许通过使用种植体直接骨骼附着假体。经皮OI植入物与皮下髓内关节植入物相似,但有一些例外。特别地,成骨不全植入物被置入股骨远端,而髓内植入物被置入股骨近端。在本报告中,介绍了用于髓内植入物(称为Gruen区域)的放射学分区分析的另一种适应性,包括四肢假体的成骨不全植入物。提出了射线照相地带性分析和解释。格林区用于髓内植入物,通常从骨的近端插入。成骨不全肢体植入物从骨的远端插入。因此,分区分析是反向的。澳大利亚骨整合小组(OGA)介绍了一种放射照相地带性分析。这种分析对于四肢成骨不全的临床评估是特别需要的,因为已经报道了骨和成骨不全植入物的显著变化,需要进行临床描述。分类技术对于建立四肢骨整合种植体的治疗指南是必要的。OGA区域分析通过采用一个通用的参考标准来解决这一需求,以适应四肢截肢者的骨整合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Technology and Innovation
Technology and Innovation MULTIDISCIPLINARY SCIENCES-
自引率
20.00%
发文量
12
期刊最新文献
VA TECHNOLOGY TRANSFER PROGRAM RESPONDS TO COVID-19 PANDEMIC. TECHNOLOGY TRANSFER ASSISTANCE PROJECT BRINGS VA HEALTH CARE IDEAS TO LIFE. On Capital, Innovation, and Government Innovative Infrared Heating Technologies for Food and Agricultural Processing Journeys of Innovation: Positively Connected
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1