{"title":"Effect of Cationization Agent Concentration on Glycan Detection Using MALDI TOF-MS","authors":"Inyoung Kim, Dongwon Shin, J. Paek, Jeongkwon Kim","doi":"10.5478/MSL.2017.8.1.14","DOIUrl":null,"url":null,"abstract":"The effect of cationization agent concentration on glycan detection via matrix-assisted laser desorption/ionization time-offlight mass spectrometry (MALDI-TOF MS) was investigated using Na+ ions in the form of NaCl as the cationization agent. NaCl solution concentrations ranging from 1 mM to 1 M were investigated. Glycans from ovalbumin were mixed with the cationization agent solution and the 2,5-dihydroxybenzoic acid (2,5-DHB) matrix solution in a volume ratio of 1:1:1. The resulting mixture was loaded onto the MALDI plate. Two MALDI-TOF MS instruments (Voyager DE-STR MALDI-TOF MS and Tinkerbell RT MALDITOF MS) were used for detection of glycans. The best detection, in terms of the number of identified glycans, the peak intensity, and the signal-to-noise (S/N) ratio, was obtained with NaCl concentrations of 0.01-0.1 M for both MALDI-TOF MS instruments.","PeriodicalId":18238,"journal":{"name":"Mass Spectrometry Letters","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2017-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mass Spectrometry Letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5478/MSL.2017.8.1.14","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 3
Abstract
The effect of cationization agent concentration on glycan detection via matrix-assisted laser desorption/ionization time-offlight mass spectrometry (MALDI-TOF MS) was investigated using Na+ ions in the form of NaCl as the cationization agent. NaCl solution concentrations ranging from 1 mM to 1 M were investigated. Glycans from ovalbumin were mixed with the cationization agent solution and the 2,5-dihydroxybenzoic acid (2,5-DHB) matrix solution in a volume ratio of 1:1:1. The resulting mixture was loaded onto the MALDI plate. Two MALDI-TOF MS instruments (Voyager DE-STR MALDI-TOF MS and Tinkerbell RT MALDITOF MS) were used for detection of glycans. The best detection, in terms of the number of identified glycans, the peak intensity, and the signal-to-noise (S/N) ratio, was obtained with NaCl concentrations of 0.01-0.1 M for both MALDI-TOF MS instruments.