Error correction of spectral response characteristic of grating spectrometer

施建华 Shi Jian-hua, 伏思华 Fu Si-hua, 谢文科 Xie Wen-ke
{"title":"Error correction of spectral response characteristic of grating spectrometer","authors":"施建华 Shi Jian-hua, 伏思华 Fu Si-hua, 谢文科 Xie Wen-ke","doi":"10.3788/CO.20140703.0483","DOIUrl":null,"url":null,"abstract":"Aiming at the big measuring error from grating spectrometer caused by the devices' spectral characterics,an error correction method is brought forward and validated. Firstly,the grating spectrometer's principle is analyzed deeply and the theoretical model of error correction is built. Then,the spectral characteristics of key devices,such as grating,detector,mirror etc.,are studied and the algorithm of numerical extraction is brought forward to acquire the value of each point on the spectral curve. Finally,the theoretical model and the method of numerical algorithm are used to correct the bromine-tungsten lamp's spectrum which is obtained by the grating spectrometer. The result of the experiment shows that the mean error of the numerical extraction algorithm is only 0. 39%,and the corrected spectrum is very close to the standard spectrum,which certifies that the correction method brought forward in this paper can eliminate the errors brought by the devices' spectral characteristics.","PeriodicalId":10133,"journal":{"name":"Chinese Journal of Optics and Applied Optics","volume":"1 1","pages":"483-490"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Journal of Optics and Applied Optics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3788/CO.20140703.0483","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Aiming at the big measuring error from grating spectrometer caused by the devices' spectral characterics,an error correction method is brought forward and validated. Firstly,the grating spectrometer's principle is analyzed deeply and the theoretical model of error correction is built. Then,the spectral characteristics of key devices,such as grating,detector,mirror etc.,are studied and the algorithm of numerical extraction is brought forward to acquire the value of each point on the spectral curve. Finally,the theoretical model and the method of numerical algorithm are used to correct the bromine-tungsten lamp's spectrum which is obtained by the grating spectrometer. The result of the experiment shows that the mean error of the numerical extraction algorithm is only 0. 39%,and the corrected spectrum is very close to the standard spectrum,which certifies that the correction method brought forward in this paper can eliminate the errors brought by the devices' spectral characteristics.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
光栅光谱仪光谱响应特性的误差校正
针对光栅光谱仪由于器件的光谱特性导致测量误差较大的问题,提出了一种误差校正方法并进行了验证。首先,深入分析了光栅光谱仪的工作原理,建立了误差校正的理论模型。然后,对光栅、探测器、反射镜等关键器件的光谱特性进行了研究,并提出了数值提取算法来获取光谱曲线上各点的值。最后,利用理论模型和数值算法对光栅光谱仪得到的溴钨灯光谱进行校正。实验结果表明,数值提取算法的平均误差仅为0。39%,校正后的光谱与标准光谱非常接近,证明本文提出的校正方法可以消除器件光谱特性带来的误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Validation method of single-channel optical system design of CO2detector SiO 2 包覆对ZnS纳米材料发光的增强机制 热蒸发与离子束溅射制备LaF 3 薄膜的光学特性 TiO 2 纳米线阵列干涉传感器 化学气相沉积法制备Zn 2 GeO 4 纳米线及其发光性质的研究
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1