Multislice B1 Mapping Method Using Magnetic Resonance Composite Spin Echo Sequences and Simultaneous Echo Refocusing

IF 0.4 4区 化学 Q4 CHEMISTRY, PHYSICAL Concepts in Magnetic Resonance Part A Pub Date : 2023-04-13 DOI:10.1155/2023/7642095
Suchit Kumar, Kyu Chan Lee, Jong-Min Kim, Jeung-Hoon Seo, Chulhyun Lee, Chang-Hyun Oh
{"title":"Multislice B1 Mapping Method Using Magnetic Resonance Composite Spin Echo Sequences and Simultaneous Echo Refocusing","authors":"Suchit Kumar,&nbsp;Kyu Chan Lee,&nbsp;Jong-Min Kim,&nbsp;Jeung-Hoon Seo,&nbsp;Chulhyun Lee,&nbsp;Chang-Hyun Oh","doi":"10.1155/2023/7642095","DOIUrl":null,"url":null,"abstract":"<div>\n <p>Radiofrequency (RF) transmit field (B<sub>1</sub>) mapping is a promising method in mitigating the B<sub>1</sub> inhomogeneity in various magnetic resonance imaging (MRI) applications. Although several phase- or magnitude-based B<sub>1</sub> mapping methods have been proposed, these methods often require complex modeling, long acquisition time, or specialized MRI sequences. A recently introduced simultaneous echo refocusing (SER) technique can be applied in the B<sub>1</sub> mapping method to extend the three-dimensional (3D) spatial coverage only without long data acquisition. Therefore, in this study, a multislice B<sub>1</sub> mapping method using composite spin echo sequences and SER techniques is proposed to obtain more accurate B<sub>1</sub> mapping with short data acquisition time. To evaluate the performance of the proposed B<sub>1</sub> mapping method, computational simulations were performed and compared with Morrell’s method, double angle method, and Yarnykh’s method. These results showed that the angle-to-noise ratio of the proposed B<sub>1</sub> mapping method has wider B<sub>1</sub> range compared to that of other B<sub>1</sub> mapping methods. In addition, the proposed B<sub>1</sub> mapping methods were compared to the multislice iterative signal intensity mapping method in both phantom and in vivo human experiments, and there was no remarkable difference between the two methods regarding the flip angle distribution in these experiments. Based on these results, this study demonstrated that the proposed B<sub>1</sub> mapping method is suitable for accurately measuring B<sub>1</sub> propagation under the condition providing reduced scan time and wider 3D coverage of B<sub>1</sub> mapping by applying composite RF pulse and SER techniques into the phase-sensitive method.</p>\n </div>","PeriodicalId":55216,"journal":{"name":"Concepts in Magnetic Resonance Part A","volume":"2023 1","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2023-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1155/2023/7642095","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Concepts in Magnetic Resonance Part A","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/2023/7642095","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Radiofrequency (RF) transmit field (B1) mapping is a promising method in mitigating the B1 inhomogeneity in various magnetic resonance imaging (MRI) applications. Although several phase- or magnitude-based B1 mapping methods have been proposed, these methods often require complex modeling, long acquisition time, or specialized MRI sequences. A recently introduced simultaneous echo refocusing (SER) technique can be applied in the B1 mapping method to extend the three-dimensional (3D) spatial coverage only without long data acquisition. Therefore, in this study, a multislice B1 mapping method using composite spin echo sequences and SER techniques is proposed to obtain more accurate B1 mapping with short data acquisition time. To evaluate the performance of the proposed B1 mapping method, computational simulations were performed and compared with Morrell’s method, double angle method, and Yarnykh’s method. These results showed that the angle-to-noise ratio of the proposed B1 mapping method has wider B1 range compared to that of other B1 mapping methods. In addition, the proposed B1 mapping methods were compared to the multislice iterative signal intensity mapping method in both phantom and in vivo human experiments, and there was no remarkable difference between the two methods regarding the flip angle distribution in these experiments. Based on these results, this study demonstrated that the proposed B1 mapping method is suitable for accurately measuring B1 propagation under the condition providing reduced scan time and wider 3D coverage of B1 mapping by applying composite RF pulse and SER techniques into the phase-sensitive method.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于磁共振复合自旋回波序列和同步回波重聚焦的多层B1制图方法
在各种磁共振成像(MRI)应用中,射频(RF)发射场(B1)映射是一种很有前途的减轻B1不均匀性的方法。虽然已经提出了几种基于相位或震级的B1成像方法,但这些方法通常需要复杂的建模、较长的采集时间或专门的MRI序列。最近引入的同步回波重聚焦(SER)技术可以应用于B1制图方法中,只需要长时间的数据采集就可以扩展三维(3D)空间覆盖。因此,本研究提出了一种利用复合自旋回波序列和SER技术的多层B1成图方法,以期在较短的数据采集时间内获得更精确的B1成图。为了评估B1映射方法的性能,进行了计算模拟,并与Morrell方法、双角度方法和Yarnykh方法进行了比较。这些结果表明,与其他B1成图方法相比,本文提出的B1成图方法的角噪比具有更宽的B1范围。此外,将所提出的B1映射方法与多层迭代信号强度映射方法进行了幻影实验和人体实验对比,两种方法在实验中翻转角分布无显著差异。基于这些结果,本研究表明,在相敏方法中应用复合RF脉冲和SER技术,在减少扫描时间和扩大B1映射三维覆盖范围的条件下,所提出的B1映射方法适用于精确测量B1传播。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.90
自引率
0.00%
发文量
12
审稿时长
>12 weeks
期刊介绍: Concepts in Magnetic Resonance Part A brings together clinicians, chemists, and physicists involved in the application of magnetic resonance techniques. The journal welcomes contributions predominantly from the fields of magnetic resonance imaging (MRI), nuclear magnetic resonance (NMR), and electron paramagnetic resonance (EPR), but also encourages submissions relating to less common magnetic resonance imaging and analytical methods. Contributors come from academic, governmental, and clinical communities, to disseminate the latest important experimental results from medical, non-medical, and analytical magnetic resonance methods, as well as related computational and theoretical advances. Subject areas include (but are by no means limited to): -Fundamental advances in the understanding of magnetic resonance -Experimental results from magnetic resonance imaging (including MRI and its specialized applications) -Experimental results from magnetic resonance spectroscopy (including NMR, EPR, and their specialized applications) -Computational and theoretical support and prediction for experimental results -Focused reviews providing commentary and discussion on recent results and developments in topical areas of investigation -Reviews of magnetic resonance approaches with a tutorial or educational approach
期刊最新文献
Density Matrix of Two Spin-1/2 Particles: Pure and Mixed States Electron Spin Resonance Spin Probe Technique for Investigating Non-TEMPO Radicals Dispersed in Nanospaces of a Crystalline Zn Complex Simulated Annealing Method for the Automated Simulation of DNA Dynamics in the HhaI Protein Binding Site Comfortable Nursing in the Intraoperative MRI Evaluation Combined with Microsurgery in the Treatment of Functional Area Glioma Effect of Early Nursing Intervention under Amplitude-Integrated Electroencephalography and Magnetic Resonance Images on Brain Injury in Premature Infants
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1