Valsalva瓣植入术后再手术或主动脉返流进展。

Q3 Medicine AORTA Pub Date : 2023-06-01 DOI:10.1055/s-0043-1768968
Kristina Ma, Emelie Carlestål, Anders Franco-Cereceda, Christian Olsson
{"title":"Valsalva瓣植入术后再手术或主动脉返流进展。","authors":"Kristina Ma,&nbsp;Emelie Carlestål,&nbsp;Anders Franco-Cereceda,&nbsp;Christian Olsson","doi":"10.1055/s-0043-1768968","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong> This study aimed to assess predictors of a composite endpoint (reoperation for aortic valve [AV] failure or aortic regurgitation [AR] grade ≥ 2) after reimplantation of the aortic valve (RAV) using the Valsalva graft.</p><p><strong>Methods: </strong> From 2012 to 2021, 112 patients underwent RAV in a single center. Clinical and echocardiographic data were collected retrospectively. Cox regression analysis was used to identify predictors of the composite endpoint. Kaplan-Meier methods were used for time-to-event analysis.</p><p><strong>Results: </strong> Median (interquartile range) age was 52 years (44, 62). Nineteen patients (17%) were operated for acute Type A aortic dissection, and the remainder for aortic root aneurysm, 60 mm or larger in 12/112 (11%). Thirty-day mortality was 1/112 (1%). During follow-up, four patients (3.6%) were reoperated for AV failure, and another nine patients (8.1%) developed AR grade ≥ 2. Overall estimated freedom from reoperation or AR grade ≥ 2 was 87% (95% confidence interval: 76-93%) at 5 years. Significantly lower estimated 5-year freedom from the composite endpoint was found in cases with simultaneous aortic valve repair (AVr; 77 vs. 90%, <i>p</i> = 0.007) and nearly significant for large (≥ 6 cm) aortic root diameter (82 vs. 87%, <i>p</i> = 0.055). In Cox's analysis, aortic root diameter and simultaneous AVr were independent predictors for the composite endpoint.</p><p><strong>Conclusion: </strong> Outcomes (survival, reoperation, freedom from AR grade ≥ 2) with RAV were good up to 11-year follow-up. Larger aortic root diameter and simultaneous AVr were identified as predictors for reoperation or AR grade ≥ 2. Long-term follow-up remains necessary to confirm adequate AV function.</p>","PeriodicalId":52392,"journal":{"name":"AORTA","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/bb/18/10-1055-s-0043-1768968.PMC10449566.pdf","citationCount":"0","resultStr":"{\"title\":\"Reoperation or Aortic Regurgitation Progression after Reimplantation of the Aortic Valve (David's Procedure) Using the Valsalva Graft.\",\"authors\":\"Kristina Ma,&nbsp;Emelie Carlestål,&nbsp;Anders Franco-Cereceda,&nbsp;Christian Olsson\",\"doi\":\"10.1055/s-0043-1768968\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong> This study aimed to assess predictors of a composite endpoint (reoperation for aortic valve [AV] failure or aortic regurgitation [AR] grade ≥ 2) after reimplantation of the aortic valve (RAV) using the Valsalva graft.</p><p><strong>Methods: </strong> From 2012 to 2021, 112 patients underwent RAV in a single center. Clinical and echocardiographic data were collected retrospectively. Cox regression analysis was used to identify predictors of the composite endpoint. Kaplan-Meier methods were used for time-to-event analysis.</p><p><strong>Results: </strong> Median (interquartile range) age was 52 years (44, 62). Nineteen patients (17%) were operated for acute Type A aortic dissection, and the remainder for aortic root aneurysm, 60 mm or larger in 12/112 (11%). Thirty-day mortality was 1/112 (1%). During follow-up, four patients (3.6%) were reoperated for AV failure, and another nine patients (8.1%) developed AR grade ≥ 2. Overall estimated freedom from reoperation or AR grade ≥ 2 was 87% (95% confidence interval: 76-93%) at 5 years. Significantly lower estimated 5-year freedom from the composite endpoint was found in cases with simultaneous aortic valve repair (AVr; 77 vs. 90%, <i>p</i> = 0.007) and nearly significant for large (≥ 6 cm) aortic root diameter (82 vs. 87%, <i>p</i> = 0.055). In Cox's analysis, aortic root diameter and simultaneous AVr were independent predictors for the composite endpoint.</p><p><strong>Conclusion: </strong> Outcomes (survival, reoperation, freedom from AR grade ≥ 2) with RAV were good up to 11-year follow-up. Larger aortic root diameter and simultaneous AVr were identified as predictors for reoperation or AR grade ≥ 2. Long-term follow-up remains necessary to confirm adequate AV function.</p>\",\"PeriodicalId\":52392,\"journal\":{\"name\":\"AORTA\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/bb/18/10-1055-s-0043-1768968.PMC10449566.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"AORTA\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0043-1768968\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"AORTA","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0043-1768968","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

背景:本研究旨在评估使用Valsalva移植物重植术(RAV)后复合终点(主动脉瓣[AV]衰竭或主动脉反流[AR]等级≥2)的预测因素。方法:2012年至2021年,在单个中心接受RAV治疗的112例患者。回顾性收集临床及超声心动图资料。采用Cox回归分析确定复合终点的预测因子。Kaplan-Meier方法用于时间-事件分析。结果:年龄中位数(四分位数间距)为52岁(44,62岁)。急性A型主动脉夹层19例(17%),60 mm及以上主动脉根动脉瘤12/112例(11%)。30天死亡率为1/112(1%)。随访期间,4例(3.6%)患者因房室功能衰竭再次手术,另有9例(8.1%)患者发生≥2级AR。总体估计5年时再手术或AR等级≥2的自由度为87%(95%置信区间:76-93%)。同时主动脉瓣修复(AVr;77比90%,p = 0.007),主动脉根直径大(≥6 cm)的患者几乎显著(82比87%,p = 0.055)。在Cox分析中,主动脉根直径和同时AVr是复合终点的独立预测因子。结论:随访11年,RAV患者的预后(生存、再手术、不再出现≥2级AR)良好。较大的主动脉根直径和同时AVr被认为是再次手术或AR等级≥2的预测因素。长期随访仍有必要确认足够的房室功能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Reoperation or Aortic Regurgitation Progression after Reimplantation of the Aortic Valve (David's Procedure) Using the Valsalva Graft.

Background:  This study aimed to assess predictors of a composite endpoint (reoperation for aortic valve [AV] failure or aortic regurgitation [AR] grade ≥ 2) after reimplantation of the aortic valve (RAV) using the Valsalva graft.

Methods:  From 2012 to 2021, 112 patients underwent RAV in a single center. Clinical and echocardiographic data were collected retrospectively. Cox regression analysis was used to identify predictors of the composite endpoint. Kaplan-Meier methods were used for time-to-event analysis.

Results:  Median (interquartile range) age was 52 years (44, 62). Nineteen patients (17%) were operated for acute Type A aortic dissection, and the remainder for aortic root aneurysm, 60 mm or larger in 12/112 (11%). Thirty-day mortality was 1/112 (1%). During follow-up, four patients (3.6%) were reoperated for AV failure, and another nine patients (8.1%) developed AR grade ≥ 2. Overall estimated freedom from reoperation or AR grade ≥ 2 was 87% (95% confidence interval: 76-93%) at 5 years. Significantly lower estimated 5-year freedom from the composite endpoint was found in cases with simultaneous aortic valve repair (AVr; 77 vs. 90%, p = 0.007) and nearly significant for large (≥ 6 cm) aortic root diameter (82 vs. 87%, p = 0.055). In Cox's analysis, aortic root diameter and simultaneous AVr were independent predictors for the composite endpoint.

Conclusion:  Outcomes (survival, reoperation, freedom from AR grade ≥ 2) with RAV were good up to 11-year follow-up. Larger aortic root diameter and simultaneous AVr were identified as predictors for reoperation or AR grade ≥ 2. Long-term follow-up remains necessary to confirm adequate AV function.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
AORTA
AORTA Medicine-Surgery
CiteScore
1.00
自引率
0.00%
发文量
119
期刊最新文献
Hybrid Treatment of Complex Para-anastomotic Aortic Arch Pseudoaneurysm. Floating Thrombus in the Aortic Arch: Rare Images. The Fate of Conventional Elephant Trunk in the Frozen Elephant Trunk Era. Ruptured Mycotic Thoracic Aortic Aneurysm in the Setting of Streptococcus Bacteremia with Underlying Colonic Malignancy. Milestone Operations in Heart Valve and Aortic Replacement: Anniversaries Worth Remembering.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1