对照组变异性与测定质量指标之间的数学关系

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS ACS Applied Bio Materials Pub Date : 2023-07-01 DOI:10.1016/j.slasd.2023.02.003
Andrew Lim
{"title":"对照组变异性与测定质量指标之间的数学关系","authors":"Andrew Lim","doi":"10.1016/j.slasd.2023.02.003","DOIUrl":null,"url":null,"abstract":"<div><p>Assay quality metrics have been used in various high-throughput screening (HTS) campaigns to indicate assay quality. Z’-factor has become one of the most widely used metrics, along with other metrics such as standardised mean difference (SSMD). In using these metrics, it is important to understand how these metrics can be impacted by the separation between control groups (indicated by the HZ ratio) and the coefficient of variation (CV) within each control group. In this paper, several mathematical equations have been derived to understand the relationship between assay quality metrics (such as Z’-factor and SSMD) and control group datasets (summarised by CV and HZ). These equations increase our understanding of the factors that improve assay quality metrics, thus providing a quantitative means to visualise how affecting control groups can impact assay quality metrics.</p></div>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mathematical relationships between control group variability and assay quality metrics\",\"authors\":\"Andrew Lim\",\"doi\":\"10.1016/j.slasd.2023.02.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Assay quality metrics have been used in various high-throughput screening (HTS) campaigns to indicate assay quality. Z’-factor has become one of the most widely used metrics, along with other metrics such as standardised mean difference (SSMD). In using these metrics, it is important to understand how these metrics can be impacted by the separation between control groups (indicated by the HZ ratio) and the coefficient of variation (CV) within each control group. In this paper, several mathematical equations have been derived to understand the relationship between assay quality metrics (such as Z’-factor and SSMD) and control group datasets (summarised by CV and HZ). These equations increase our understanding of the factors that improve assay quality metrics, thus providing a quantitative means to visualise how affecting control groups can impact assay quality metrics.</p></div>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"99\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2472555223000163\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"99","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2472555223000163","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

化验质量指标已用于各种高通量筛选(HTS)活动,以指示化验质量。Z’因子与标准化平均差(SSMD)等其他指标一起,已成为最广泛使用的指标之一。在使用这些指标时,重要的是要了解这些指标如何受到对照组之间的分离(由HZ比率表示)和每个对照组内的变异系数(CV)的影响。在本文中,推导了几个数学方程来理解分析质量指标(如Z’-因子和SSMD)与对照组数据集(用CV和HZ总结)之间的关系。这些方程增加了我们对提高测定质量指标的因素的理解,从而提供了一种定量方法来可视化影响对照组如何影响测定质量指标。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Mathematical relationships between control group variability and assay quality metrics

Assay quality metrics have been used in various high-throughput screening (HTS) campaigns to indicate assay quality. Z’-factor has become one of the most widely used metrics, along with other metrics such as standardised mean difference (SSMD). In using these metrics, it is important to understand how these metrics can be impacted by the separation between control groups (indicated by the HZ ratio) and the coefficient of variation (CV) within each control group. In this paper, several mathematical equations have been derived to understand the relationship between assay quality metrics (such as Z’-factor and SSMD) and control group datasets (summarised by CV and HZ). These equations increase our understanding of the factors that improve assay quality metrics, thus providing a quantitative means to visualise how affecting control groups can impact assay quality metrics.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
期刊最新文献
A Systematic Review of Sleep Disturbance in Idiopathic Intracranial Hypertension. Advancing Patient Education in Idiopathic Intracranial Hypertension: The Promise of Large Language Models. Anti-Myelin-Associated Glycoprotein Neuropathy: Recent Developments. Approach to Managing the Initial Presentation of Multiple Sclerosis: A Worldwide Practice Survey. Association Between LACE+ Index Risk Category and 90-Day Mortality After Stroke.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1